AAdynTech JAB Users Manual

JAB Series Light
User Manual (IP60 Protection)
SB-219 REV C 1
Table of Contents
Before You Begin ...................................................................................................................................................... 3
What is Included .................................................................................................................................................. 3
Unpacking Instructions ........................................................................................................................................ 3
Symbol Definitions ............................................................................................................................................... 3
Safety Notes ......................................................................................................................................................... 3
Introduction ............................................................................................................................................................. 4
Product Description ............................................................................................................................................. 4
Features ............................................................................................................................................................... 4
Setup ........................................................................................................................................................................ 5
Mounting.............................................................................................................................................................. 5
AC Power .............................................................................................................................................................. 7
Control Selection .................................................................................................................................................. 7
Operation ................................................................................................................... ................................................8
UIM Operation ..................................................................................................................................................... 8
DMX Operation .....................................................................................................................................................12
Technical Information ............................................................................................................................................ 13
General Maintenance and Care ......................................................................................................................... 13
Troubleshooting Guide ...................................................................................................................................... 13
Limited Warranty ............................................................................................................................................... 13
Contact Us .......................................................................................................................................................... 14
Specifications………………………………………………………………………………………………………………15
SB-219 REV C 2
Note: This symbol indicates important information that should be
Note: This symbol indicates important safety information and Note: This symbol indicates important information concerning the

Before You Begin

What is Included

User’s Manual
One (1) IP60 Rated JAB Series light fixture
AC Power Input cable with plug
o USA voltage (120Vac), three-prong plug standard o One (1) 120/240v Adapter
Diffuser lens, three (4), 5 ,15
One (1) Yoke Pin with attaching hardware
User Interface Module , UIM (Included, if purchased – Optional)

Unpacking Instructions

Immediately upon receipt of this light, carefully inspect the shipping packaging for any obvious signs of damage from mishandling or exposure to the elements. If any is noted, please provide this information to the shipper immediately so that the proper claims can be processed. Place packaging in upright position (with labeling and markings in readable orientation) and open the top end of the carton. Verify that all material shown above in the “What is included” section is present and in good condition. Remove the light and associated material from the carton and place the light on a stable surface or mounting configuration.
o
, 30o and 55o

Symbol Definitions

carefully considered and followed.
warnings. Special attention should be paid to reading, understanding and heeding these warnings. Failure to observe these warnings could result in damage to the fixture,
operation or functions of this light.
SB-219 REV C 3
Note: This light contains no user serviceable parts. Do not open Warning! Inserting objects or fingers inside any openings or
damage to the light.

Safety Notes

The JAB Series light fixtures are for professional use only. Please Read Entire User Manual Before
Using Equipment.
This light is intended for indoor use only. This unit is ETL, CSA & CE approved for IP60 protection.
Only qualified and certified personnel should perform installation, not for household use.
JAB Series lights should always be installed/mounted in a stable and secure location or mounting.
Make sure that light is only used in dry location. Do not use light in or around falling water, wet
locations or moisture.
Always allow adequate ventilation of the light. Never cover or in any way obstruct the louver e d openings in the light.
If light is suspended either from above or below using yoke, make sure that a safety cable (not supplied) is attached to the light and properly secured. The strength of the cable/chain should be sized suitably to hold 6 times the weight the secured light.
When mounting the light, make sure that only hardware rated for the weight and size of the fixture is used and is in proper working condition.
Never look directly into the light source while the fixture is turned on. Light source is very bright and could cause damage to eyes.
Do not probe or touch any interior features of the fixture. This includes the LED sources inside the barrel of the light. Doing so may cause damage to the fixture and/or may present a shock or burn hazard.
Always make sure that the light fixture is connected to the proper power source with proper voltage and current ratings. Also, make sure that adequate over current protection is provided for the circuit as well.
the light housing or attempt any repair or modification of the light. Failure to observe this warning could result in damage to the light, injury and/or voiding the limited warranty.
connectors could result in a shock hazard/injury and

Introduction

Product Description

The JAB series light is a professional grade, LED based fixture which provid es ex c eption al light output
and control. The light is capable of either tethered remote or DMX control and offers a full array of brightness settings as well as Strobe and Lightning functions.

Features

Integrated UIM control
DMX control (Compatible with Slow and Fast speeds)
o Up to 500 selectable DMX addresses o Daisy-chain operation of up to 32 lights in one string o Controls Brightness, Fade, Strobe and Lightning modes
SB-219 REV C 4
Prior to proceeding further, make sure that light is resting on a stable surface or is mounting system.
Make note of the location of the inputs and outputs along with the light controls

Setup

Quick Start

Remove the Aadyn light from its protective shipping packaging and place it in a safe and secure location for setup or use.
properly attached to a mounting location using the supplied yoke and yoke pin
found on the light’s control box as pictured below.
SB-219 REV C 5
Warning! Lights operate on grounded 110Vac, 50/60Hz or 240Vac, 50/60Hz
Warning! Lights are intended for indoor operation and use only. Use in a safe and dry location onl y. KEEP FIXTURE DRY
Aadyn Technology
The AC power cable & DC power cable will be found tie wrapped & coiled up inside of the yoke attached to the power supply inside the shipping container.(if ordered with light package)
Uncoil the AC and DC cord plugging the DC female end into the DC power input located on the back of the control box (pictured above)
AC Input. AC Supply Source must be sized properly and have approved protection circuitry for safe operation. Take care to observe all proper precautions when con nec ti ng po wer .
Plug the male end of the AC power cord into an appropriate AC power source.
Turn on light by pressing the black power switch located in the upper left hand portion of the control box,
shown above.
Using the Integrated UIM located on the right side of the control box select the desired mode in which you wish to operate the light. UIM or DMX.
Upon power up, the factory default setting will turn the light immediately to its full brightness unless a
specific “Power On” Setting which has been previously programmed into the light. This “Power On” Setting will be covered later in these instructions.
If a UIM, optional remote controller is ordered with the light package, it will be located in a separate
box within the package the Jab light was shipped in. The length of the cable is 12’. Remove the UIM from the box, uncoil the UIM cable and attach the connector on the cable to the UIM connector located on the control box.
The display on the UIM will display the following Splash Screen message upon power up.
Remote Interface
Using the Left/Right Arrow button, a desired brightness level can be selected. Other functions are
also available and can be viewed using the UIM by pressing the Up/Down arrow to the desired menu function as detailed below in section 1.0, then pressing the (√) once a function has been selected. All of these functions are covered later in these instructions.
The (X) button on the UIM is a non-latching douse switch which, when pressed, will momentarily
extinguish the light. Releasing the switch will allow the light to return to operation at its previous setting.
SB-219 REV C 6

AC Power

Warning! Standard power cord supplied with JAB light is intended to connect
voltages.
Warning! Never connect JAB series lights to anything other than a single­+ Voltage Side
- Voltage Side
1
2
Warning! DC power connection from external battery (not supplied) must mate
4
3
JAB series lights operate on standard single phase AC power.
Input voltage range: 100 – 277Vac
Input frequency range: 50/60 Hz
with standard, single-phase 110-120 Vac, 60 Hz USA circuit. An adaptor for use with 240Vac, 50Hz European circuits is als o includ ed. Other power cords for connection to other countries’ single phase circuits are available as options. No other special adjustments or changes are required for operation at international
phase circuit. Connection to three-phase power can/will cause serious damage and/or bodily injury.

DC Power

As an alternative to standard AC operation, JAB Hurricane lights can also operate on 30Vdc(max) power provided by an external battery (not supplied).
Operational input DC voltage range: 22 Vdc –30Vdc (max)
Light will not function at DC ranges above or below range shown
properly with four pin power connector on back of light module. Contact AAdyn Technology for further details or information.
SB-219 REV C 7

1. Functional Requirements

The following sections provide all of the functional requirements for the AADYN Jab Lights software.

1.1. Mode Selector Switch

The software shall monitor a switch input to determine if the light should be in DMX mode, Local
Brightness and Color Temperature mode, or UIM mode. The switch may also be absent, if which case the UIM will need to be used to perform this function. This “LIGHT CONTROL” menu will only be present if the mode selector switch is not installed and in its place is a special jumper block that grounds the two inputs.

1.2. Local Mode (only applies to Hurricane model)

This mode shall be active when the Mode Selector switch is set to Local Mode.
The software shall monitor a potentiometer input for signal changes to indicate whether the user
wishes to make the light dimmer or brighter. The software shall also monitor a potentiometer for signal changes to indicate whether the user wishes to mix the color temperature. The requirement to monitor the color temperature potentiometer shall apply only to the Hurricane Variable Light model.
The BRIGHTNESS and COLOR TEMPERATURE controls shall be the only LED functions available
when in Local Mode.
All non-LED menu items on the UIM shall be working in Local Mode with the exception of POWER
ON SETTING at power on.
Cancel (X), (also called the Douse button), and the Douse Switch shall function in Local Mode.
This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.

1.3. DMX Mode

This mode shall be active when the Mode Selector switch is set to DMX. Or when the UIM LIGHT
CONTROL menu “DMX” option has been selected.
The software shall allow only the DMX input to adjust the LED functions while in DMX Mode.
All non-LED menu items on the UIM shall be working in DMX Mode with the exception of POWER
ON SETTING at power on.
The back panel Douse Switch and the UIM Douse Button shall function in DMX Mode.
This mode shall not have any built-in fade when changing brightness.

1.4. UIM Mode

This mode shall be active when the Mo de Selector switch is set to UIM. Or when the UIM LIGHT
CONTROL menu “UIM” option has been selected.
The software shall allow only the UIM input to adjust the LED functions while in UIM Mode.
The Douse Switch and the Douse Button shall function in UIM Mode.
This mode shall have a built-in 250 millisecond fade when changing brightness to help smooth out
the light transition.

1.5. Proprietary User Interface Module Requirements

All functions in this section shall be available for use when the Mode Selector switch is set to UIM
mode. Or when the UIM LIGHT CONTROL menu “UIM” option has been selected.
The software shall display a menu of parameters on the UIM controller. The parameters listed below shall be displayed in the order shown from top to bottom when the down key is pressed and shall default to UIM BRIGHTNESS. When the up key is pressed the order will proceed from LIGHT CONTROL to the bottom of the list, then upwards.
UIM BRIGHTNESS
UIM COLOR (Jab Variable model)
UIM FADE
UIM EFFECT SELECT
UIM EFFECT FREQUENCY
SB-219 REV C 8
DMX BASE ADDRESS
DMX CHANNEL MODE
MODEL NAME / SOFTWARE VERSION / RECALIBRATION PT
POWER ON SETTING
SAVE CUSTOM
RECALL SETTI NG
LIGHT CONTROL (only if mode switch is absent)
Under each parameter, the software shall present settings pertaining to the parameter for the user to
select. The settings shall be:
BRIGHTNESS parameter:
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a brightness level where 0 percent is off and 100
percent is the maximum brightness of the light.
The change from one brightness value setting to another value shall be as smooth as
possible. The built in smoothing delay shall be 250ms. If the BRIGHTNESS slider on a DMX board is taken from a positive value all the way to 0, the software shall not implement any delay unless FADE is non-zero and turn the light off immediately.
At power on, the factory default value of UIM BRIGHTNESS shall be set at 100%. If a
power on profile is selected that brightness setting will be used. If there is no power on profile, the brightness will be the ‘last used’ level.
COLOR TEMP parameter (applies only to Jab Variable Light model):
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a light color temperature lev el wher e 0 percent is
completely cool and 100 percent is the maximum warm setting of the light.
At power on, the factory default value of UIM COLOR TEMP shall default to 50 percent.
If a power on profile is selected that associated brightness level will be used, else the ‘last used’ brightness level will be used.
FADE parameter:
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
Each setting value shall represent a delay in the increase or decrease of the
BRIGHTNESS parameter.
0 shall indicate that the BRIGHTNESS parameter change is to occur immediately and
100 percent shall introduce a three second delay in changing the current parameter value to the requested value.
At power on, the factory default value of UIM FADE shall default to 0 percent. If there is
a power on profile, its associated FADE level shall be used, else the ‘last used’ value will be used.
EFFECT SELECT parameter:
The software shall present individually thirteen choices for the EFFECT SELECT
parameter:
NONE (OFF) – Turn off any current effect
STROBE,
LIGHTNING1 SGL,
LIGHTNING1 RPT,
LIGHTNING2 SGL,
LIGHTNING2 RPT,
LIGHTNING3 SGL,
LIGHTNING3 RPT,
SB-219 REV C 9
LIGHTNING4 SGL,
LIGHTNING4 RPT,
LIGHTNING5 SGL,
LIGHTNING5 RPT,
LIGHTNING CYCL
The choice shall change by one each time a right or left arrow button is pressed.
STROBE shall make the LEDs emit pulses of light at a 30 percent on/70 percent off duty
cycle and that are of a user designated frequency and brightness. These parameters are EFFECT FREQUENCY and BRIGHTNESS.
LIGHTNINGx SGL shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. SGL indicates that this sequence shall be shown only once per user request. The length and brightness components of lightning shall be defined in the software. There shall be five different sequences of lightning defined and designated by a number where the x is located.
LIGHTNINGx RPT shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. RPT indicates that this sequence shall be shown repeatedly, with each sequence separated by a two second off interval. The length and brightness components of lightning shall be defined in the software. The same five single sequences defined above shall be used for the repeat lightning.
LIGHTNING CYCL shall show each sequence in order with each sequence separated
by a two second off interval. At the end of the fifth sequence, the process shall be repeated.
If a LIGHTNING effect has been started, it shall be completed even if the user disables
effects during the sequence.
At power on, the factory default UIM EFFECT SELECT shall default to NONE(OFF). If
there is a power on profile the effect associated with that profile will be used, else the ‘last used’ value will be used.
EFFECT FREQUENCY parameter:
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall scroll by five.
The power on default value of the UIM EFFECT FREQUENCY parameter shall be 75
percent. If a POWER ON SETTING has been selected, the EFFECT FREQUENCY shall be the value specified in that setting. If the POWER ON SETTING is turned OFF, the software shall use the ‘last used’ value’.
Each setting value shall represent how quickly the lightning and strobe effects operate.
Higher numbers represent a slower effect.
RECALL SETTING parameter:
The software shall present individually fifteen choices to the user: PRESET1, PRESET2,
PRESET3, and CUSTOM1 through CUSTOM12 changing the choice each time a right or left arrow button is pressed. The CUSTOM settings are described below.
The PRESET settings shall be hard coded into the software and not changeable by the
user.
When the user presses the select (green check) button, the software shall set the
BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX Channel Mode, and COLOR TEMP (if the light is a Jab Variable model) parameters with the saved settings from a CUSTOM or a PRESET, given the profile the user has chosen.
At power on, the RECALL SETTING that is displayed (but not selected) shall default to
PRESET1 if there is no power on profile.
For all 3 Presets the FADE and EFFECT FREQUENCY shall be zero, and the effect
shall be NONE. Also for all presets the DMX base address shall be 1 and the DMX Channel Mode shall be 6.
There shall be three factory presets for the Jab Variable
light.
SB-219 REV C 10
For each, the BRIGHTNESS shall be 100%. Preset one shall set COLOR TEMP at
100%, Preset two shall set the COLOR TEMP at 45% and Preset three shall set the COLOR TEMP at 10%.
For the Jab Tungsten and Jab Daylight models the Color temp will always be 0%. Preset
1 will have 100% brightness, Preset 2 will have 45% brightnes s , and Pres et 3 will ha ve 25% brightness.
For all presets the DMX channel will be 1 and the Channel Mode will be 6.
SAVE CUSTOM parameter:
The software shall present individually twelve choices to the user: CUSTOM1 through
CUSTOM12 changing the choice each time the right or left arrow button is pressed.
When the custom setting is selected (green check button) by the user, the software shall
save the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY, DMX Channel, DMX Channel Mode, and COLOR TEMP (if the light is a Jab Variable model) to non-volatile memory.
POWER ON SETTING parameter:
The software shall individually present sixteen choices to the user: PRESET1,
PRESET2, PRESET3, CUSTOM1 through CUSTOM12, and OFF changing the choice each time the right or left arrow button is pressed.
When the setting is selected by the user, the software shall save this choice to non-
volatile memory.
When the light is powered on, the software shall check to see if there is a startup profile
selected and set the BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and COLOR TEMP (if the light is a Jab Variable model) parameters with the saved settings from the profile.
If no power on default is selected when the light is powered up in UIM control mode the
firmware shall restore BRIGHTNESS, FADE, EFFECT, EFFECT FREQUENCY and COLOR TEMP (if the light is a Jab Variable model) settings that were saved from the last time the light was used These settings shall be automatically saved every two seconds if any have changed since the last check.
At power on, POWER ON SETTING shall default to OFF if there is no power on profile.
MODEL NAME parameter:
Each model shall have its name displayed on the UIM MODEL NAME screen.
The name shall be one of the following: JAB DAYLIGHT, JAB TUNGSTEN or JAB
VARIABLE, depending on which model is being built.
RECALIBRATION PT parameter:
The software shall start at 25000 hours and count down to zero and then count
negatively if necessary to let the user know it is time to have the LED’s replaced. The time shall count down based on hours of continuous use at a particular brightness setting.
SOFTWARE VERSION parameter:
The software shall maintain and display the software version.
It shall be in the form: MajorVersion.MinorVersion.Build
DMX BASE ADDRESS parameter:
This parameter shall range between 1 and 512. It shall represent the DMX address on
the network that is used to address the light.
DMX CHANNEL MODE
There shall be three modes of operation when the light is under DMX control. These
modes are called: 2 CHANNEL, 3 CHANNEL, and 6 CHANNEL mode. In all modes the first slider controls brightness. In 2 channel mode the second slider controls color temperature for the Jab Variable model, and has no effect on the other two models. The third slider controls fade in 3 and 6 channel modes. In 6 channel mode slider 4 controls effect selection, 5 controls effect frequency, and slider 6 controls effect activation.
The factory default for the DMX CHANNEL MODE shall be
SB-219 REV C 11
6 CHANNELS mode.
LIGHT CONTROL (Only applies to ECO Jab models)
There shall be two control modes of operation when the Mode Select switch is absent.
These modes are called: UIM and DMX. In UIM mode the UIM controls all light functions. In DMX mode the DMX interface controls all light functions.
The factory default for the LIGHT CONTROL shall be UIM.
The software shall implement medium, medium fast and fast scroll where noted. If the Right or Left
Arrow button is held down for one half second, the values shall be medium scrolled on the display. If the Arrow button is held down for two seconds the values shall be medium fast scrolled on the display. If the Arrow button is held down for six seconds the values shall be fast scrolled by five on the display.
The software shall make sure that the LED’s are powered by the slave PWM processor based on default settings and/or any saved profile described under POWER ON SETTING before detecting the presence of a UIM (User Interface Module).
If a UIM cannot be detected at light startup, the software shall transmit the AADYN TECHNOLOGY splash screen and check again next time through the main loop. If a UIM is attached after startup, the software shall display the BRIGHTNESS screen after a five (5) second delay with the splash screen being shown.
If the UIM is removed after startup, the software shall maintain the current settings. If the UIM is reattached later, the splash screen shall show again and any value in the buffer shall be processed. The software shall retain the menu state after the UIM is unplugged and, if the UIM is reattached, the splash screen shall show again until any button is pressed. If a benign button is pressed, then the previous menu shall be displayed; otherwise, the button shall be acted upon and the displa y shall be updated appropriately.
The backlight of the UIM shall be tuned off if the user does not press any button for a period of two minutes. The next subsequent button press shall only turn the backlight on with no additional action being taken. This includes the UIM douse button.

1.6. Douse Switch/Douse Button

The software shall monitor an I/O pin to determine if a momentary switch connected to the light has
been pressed and shall turn off the light for the duration of the switch press.
Upon release, the software shall allow the light to return to its currently set brightness level if the
Cancel button on the UIM is not pressed.
The software shall separately detect and process a press and release of the red Cancel (X) button
from the UIM. On Cancel button press, the software shall turn off the LED’s immediately. On Cancel button release, the software shall turn on the LED’s immediately if the Douse switch is not being pressed.

1.7. DMX Controller Interface Requirements

The software shall accept input from the DMX512 controller that represents user requested values
for BRIGHTNESS, COLOR TEMP (if light model is a Jab Variable), FADE, EFFECT, EFFECT FREQUENCY and EFFECT ACTIVATION.
The DMX input to the light is mapped as follows:
Channel 1: Brightness: 0 – 255
Channel 2: Color Temperature: 0 – 255
SB-219 REV C 12
Channel 3: Fade: 0 – 255
Channel 4: Effects: 0: No Effect Selected 1 – 40: Lightning 1 Selected 41 – 80: Lightning 2 Selected 81 – 120: Lightning 3 Selected 121 – 160: Lightning 4 Selected 161 – 200: Lightning 5 Selected 201 – 255: Strobe Selected
Channel 5: Effect Frequency: 0 – 255
Channel 6: Effect Activation 0: Effect Deactivated 1 – 255: Effect Activated

Technical Information

General Maintenance and Care

This light is intended for indoor use only. When not in use, the light should be stored in a generally dry
and dust free area. General maintenance and care consists of making sure that the light always has good ventilation and that nothing is obstructing free air flow through and around the light. Do not use chemicals to clean light. Any cleaning of the light, especially the LED optics should be with a damp, not wet, soft cloth that is non-abrasive.
Limited Warranty
AADYN TECHNOLOGY, LLC

LIMITED WARRANTY

AAdyn Technology, LLC (“AAdynTech”) products are covered by a limited warranty against manufacturing
defects for two (2) years f rom the date of purchas e by the origi nal purc haser. AAd ynTech ’s liabilit y is limit ed, at AAdynTech’s option, to repair or replacement of the product with the same or an equivalent product and does not include installation costs, removal costs, or transportation costs. AAdynTech reserves the right to determine whether the AAdynTech product is defective. Damage due to normal wear and tear, incorrect installation, misuse, abuse, accident, or an y cause other than a manufac turing defect is not covered by the warranty. AAdynTech disclaim s an y liab ilit y fo r da m age to prod ucts, adapt ers, oth er pro pert y, or per son al inj ur y result ing in whole or in part, from improper instal lation or use of its products. C omponents not m anufactured b y AAdynTech are s ubject to the warranty or guarantee set forth by the manufacturer thereof, and then only to the extent AAdynTech is able to enforce the warranty or guarantee.
In order to mak e a warranty c laim , you mus t notif y AA dynTech in writing with in si xt y (60) d ays af ter your
discovery of the defect, obtain from AAdynTech an RMA, then provide proof of purchase, such as the invoice, and promptly return the product to AAdynTech or its authorized service provider, freight prepaid.
THE FOREGOING WARRANTY PROVISIONS ARE EXCLUSIVE AND ARE
GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY
SB-219 REV C 13
WARRANTY AGAINST INFRINGEMENT AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
Jab Daylight
No Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 94,920 26,590 12,680
Ft. Candles 8,810 2,503 1,177
5° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 67,100 18,550 9,090
Ft. Candles 6,233 1,723 845
15° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 49,200 13,290 6,380
Ft. Candles 3,595 1,018 474
30° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 16,610 4,265 2,040
Ft. Candles 1,543 396 189
55° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 5,995 1,415 690
Ft. Candles 557 131 64
FITNESS FOR A PARTICULAR PURPOSE.
IN NO EVENT SHALL AADYNTECH BE LIABLE FOR INCIDENTAL, COMPENSATORY,
CONSEQUENTIAL, DIRECT, SPECIAL OR OTHER DAMAGES. AADYNTECH’S AGGREGATE LIABILITY WITH RESPECT TO A DEFECTIVE PRODUCT SHALL IN ANY EVENT BE LIMITED TO THE REPAIR OR REPLACEMENT O F T H AT DEFECT IVE PRODUCT O R, AT AADYNTECH’S O PTION, THE REIMBURSEMENT OF THE PURCHASE PRICE THEREFOR.
This warranty is eff ective for purchases of AAdynTec h’s product on or after the effective date set forth
below. AAdynTech reserv e s the right to modify this warranty fr om tim e to tim e. An y m odific ation of this warranty shall be effective for all orders placed with AAdynTech on or after the effective date of such revised warranty.
Effective Date: November 11, 2014

All prices and specifications are subject to change without notice.

Contact Us

Aadyn Technology, LLC Route 80 4 East- Suite 120 Paramus N. J. 07652 (201) 368-2800
PHOTOMETRIC DATA FOR JAB SERIES FIXTURES
SB-219 REV C 14
Jab V2 Variable
No Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 71,640 22,590 9,925
Ft. Candles 6,655 2,099 922
5° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 52,800 16,250 6.890
Ft. Candles 4,980 1,509 640
15° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 38,700 10,960 5,100
Ft. Candles 3,595 1,018 474
30° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 14,980 4,265 1,710
Ft. Candles 1,392 396 159
55° Diffuser @ 5 Feet @ 10 Feet @ 15 Feet
Lux 5,995 1,415 690
Ft. Candles 557 131 64
Dimensions
Length
339.0 mm
13.3 in
Width
326.5 mm
12.9 in
Height
554.9 mm
21.8 in
Weight
8.9 kg
19.5 lbs
SB-219 REV C 15