3onedata IES618-2F-4D(RS-232)-P, IES618-4DI(RS-485)-P, IES618-2F-4DI(RS-485)-P, IES618-4F-4DI(RS-485)-P, IES618-4F-4D(RS-232)-P User Manual

IES618-4D series
Industrial Ethernet switch
User manual
Shenzhen 3onedata Technology Co., Ltd.
www.3onedata.com
Summarize】
IES618-4D series is a industrial, management, redundant industrial Ethernet switch and integrate 4 po rt serial devi ce server. It included
1. IES618-4D(RS-232)-P(12/48VDC), Support 8 port 10/100Base T(X) and 4 port RS-232,
2. IES618-4DI(RS-485)-P(12/48VDC), Support 8 port 10/100BaseT(X) and 4 port RS-485/422,
3. IES618-4F-4DI(RS-485)-P(12/48VDC), Support1-4 port is 10/100BaseT(X) Ethernet, 5-8 port is 100BaseFX fiber port and 4 port RS-485/RS-422,
4. IES618-2F-4D(RS-232)-P(12/48VDC), Support1-6 port is 10/100BaseT(X) Ethernet, 7-8 port is 100BaseFX fiber port and 4 port RS-232,
5. IES618-4F-4D(RS-232)-P(12/48VDC), Support1-4 port is 10/100BaseT(X) Ethernet, 5-8 port is 100BaseFX fiber port and 4 port RS-232,
6. IES618-2F-4DI(RS-485)-P(12/48VDC). Support1-6 port is 10/100BaseT(X) Ethernet, 7-8 port is 100BaseFX fiber port and 4 port RS-485/422, it adopted SW-Ring redundant technology (Recovery time<20ms), users can set the redundant easily to increase network reliabili ty, furthermore. It adopted no fan, low power consumption design, IP40, corrugate high strength iron shell, the performance is more steadily. It accorded with CE, FCC standard and Industrial 4 class, DIN rail installation and wide operating temperature (-40~75), it can satisfied some kinds of industrial environment, it can provide reliable and quickly solution for your Ethernet device
Packing list】
Please check the packaging and accessories by your first using.
Industrial Ethernet switch(IES618-4D series) 1 User manual 1 CD 1 Certificate of quality 1
Warranty card 1
Please inform us or our distributor if your equipment’s have been damaged or lost any accessories, we will try our best to satisfy you.
Features】
IEEE802.3, IEEE802.3u, IEEE 802.3x, IEEE802.1Q,
IEEE802.1p, IEEE802.1D, IEEE802.1W
Support SW-RingTM redundant network patent technology
(Faulty recovery time<20ms)
Support IEEE802.1Q VLAN configuration,
Control broadcast storm effectively
Support 802.1p _QOS Support RSTP Support SNMP Support IGMP snooping, static multicast filter, port trunking
and port mirroring
Support port bandwidth limited function, optimize
bandwidth utilize
Support 4 port RS-232/ RS-485/ RS-422 serial device server Support based on socket application access Support Sever, Client, UDP based mode and Sever, UDP
advanced mode
Support Windows serial driver procedure mode Support TCP, UDP, ARP, ICMP and DHCP protocol Support cross-gateway and cross-router communication Specific serial self-adapt function (Realcom) Support Web, CLI, Telnet management Support 2K MAC address table Support 2 power supply input and 1 relay alarm output Support port line and redundant network faulty/unusual,
local and remote alarm
High strength iron shell, IP40 protection Industrial 4 class design Redundant 24VDC power supply input(1248VDC)
-40~75 working temperature DIN-rail, wall mounting installation
Panel Layout】
IES618-4D series
Back view Top and below view
IES618-4D(RS-232)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-232 port
8. 10/100Base-TX RJ45 port
9. LED indicator Front view
IES618-4DI
RS-485)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-485.422 port
8. 10/100Base-TX RJ45 port
9. LED indicator
Front view
IES618-2F-4D
RS-232)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-232 port
8. 10/100Base-TX RJ45 port
9. 100Base-FX fiber port
10. LED indicator
Front view
IES618-4F-4DI(RS-485)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-485/422 port
8. 10/100Base-TX RJ45 port
9. 100Base-FX fiber port
10. LED indicator Front view
IES618-2F-4DI
RS-485)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-232 port
8. 10/100Base-TX RJ45 port
9. 100Base-FX fiber port
10.
LED indicator Front view
IES618-4F-4D(RS-232)-P(12/48VDC)
1. PWR1/PWR2 power supply
2. Ground screw
3. Relay output terminal block 4 Console port
5. DIP switch (4 bits)
6. DIN-Rail
7. RS-485/422 port
8. 10/100Base-TX RJ45 port
9. 100Base-FX fiber port
10. LED indicator Front view
Appearance and dimension】
Unit(mm)
Front view Back view
Power supply input】
Vertical view Top view
IES618-4D series provide 4 bits industry terminal block (V1-, V1+, V2-, V2+), V-, V+ is 1248VDC power supply input.
IES618-4D series DC power supply input supported redundancy function, provided PWR1 and PWR2 power input, can use for single, and can connect 2 separately power sup ply system, use 1 pair terminal block connect the devi ce at the same time. If one of the power system broke, the device can work un-interruptible. built-in over current protection, Reverse connection protection
Console port】
IES618-4D series provided 1pcs procedure test port based in serial port. It adopts RJ45 interface, located in top panel, can configure the CLI command through R J45 to DB9 female cable.
Relay connection
Vertical view Top view
The relay owns two contacts of the terminal block on the top panel of IES618-4D series. It is used to detect both power failure and port failure. The two wires attached to contacts form an open circuit when:
(1) IES618-4D series has lost power supply from one of the
DC power inputs.
(2) One of the ports is failure.
DIP switch】
Top panel provided 4 bits DIP switch to do function configureOFF is default factory,1 and 4 keep for future function. 3 is recovery default facto ry. 2 is for upgrade. P lease power off and power on when you change the status of DIP switch.
Communication connector】
10/100BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP. The connect distance is no more than 100m. 100Mbps is used 120 Ωof UTP 5 , 10Mbps is used 120Ωof UTP 3,4,5.
RJ 45 port support automatic MDI/MDI-X operation. can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connection in MDI. 1→3,2→6,3→1,6→2 are used
as cross wiring in the MDI-X port of Converter and HUB. 10Base-T/100Base-TX are u sed i n M DI/M DI-X, the define of Pin in the table as below.
NO. MDI signal MDI-X signal 1 TX+ RX+ 2 TX- RX­3 RX+ TX+ 6 RX- TX­4, 5, 7, 8
Note:“ TX±”Transmit Data± ,“ RX±”Receive Data± ,“ —”Not Use
MDI (straight-through cable)
1 8
MDI-X (Cross over cable)
MDI/MDI-X auto connection makes IES5028-4GS-2F easy to use for customers without considering the type of network cable.
100Base-FX Fiber port
100Base-FX full-duplex SM or MM port, SC/ST type .The fib er port must be used in pair, TX (transmit) port connect remote switch’s RX(receive) port; RX(receive) port connect remote switch’s TX(transmit) port.
The optical fiber connection supports the line to instruct enhance the reliability of network effectively
.
Suppose: If you make your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, shown as below, or A1-to-A2 and B1-to-B2).
RS-232 port:
PIN RS-232
1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9
DB9 male (RS-232)
RS-485 port:
PIN RS-485
1 D+ 2 D­3 / 4 /
5
/
RS-422 port:
PIN RS-422
1 T+
2
T-
3 GND 4 R+
5
R-
RS-485/422
LED indicator】
IES618-4D series LED indicator light on the front panel .the function of each LED is described in the table as below:
System status LED
LED
Indicator Description
PWR1
ON P1 connection regularly OFF P1 Power supply have no connection or
unwonted
PWR2
ON P2 connection regularly OFF P2 Power supply have no connection or
unwonted
Alarm
ON
Power, port have alarm
OFF Power, port have no alarm
Run
ON Device unwonted Blinking Device working steadily, Blinking per
second
Link/Act
ON Established effective
network connection Blinking Network in activity status OFF Did not establish effective
network connection
TX
Blinking Transmit data unwonted OFF Transmit data wonted
RX
Blinking Receive data unwonted OFF Receive data wonted
Installation】
Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant space. Whether it is close to the connection equipment and other equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Screw, nut, tool provide by yourself.
5. Power: redundant 12-48VDC o power input
6. Environment: working temperature -4075
Relative humidity 5%95%
DIN rail installation
In order to use in industrial environments expediently, IES618-4D series adopt 35mm DIN-Rail installation, the installation steps as fellows:
1. Examine the DIN-Rail attachment
2. Examine DIN Rail whether be firm and the position be
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the stiff
metal spring.
4. Th e DIN-Rail attachment unit will snap into place as s hown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and specification of cable match t he requirement before cable laying;
2. It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable laying;
3. The required cable specification , quantity, direction and laying position need to match construction requirements, and cable length depends on actual position;
4. All the cable cannot have b reak-down and terminal in the middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the groove in case of holding back the inlet and outlet holes. Cables should be banded and fixed when they are out of the groove;
7. User cable should be separated from the power lines. Cables, power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road. When cable is too long, it cannot hold down other cable, but structure in the midd le of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible. Swerving radiu s canno t be too small (small swervi ng causes terrible loss of link). Its banding should be moderate, not too tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the cable for maintaining.
Specification】
Technology
Standard: IEEE802.3, IEEE802.3u, IEEE 802.3x, IEEE802.1Q, IEEE802.1p, IEEE802.1D, IEEE802.1W Protocol: ARP, ICMP, TCP, UDP, DHCP, DNS, HTTP, Telnet, SW-RingTM
Flow control: IEEE802.3x, back pressure control
Function
Function: SW-RingTM, QOS, 802.1Q VLAN, port-trunking, static multicast filter, port mirroring, Broadcast storm control, flow statistics, upgrade online, up and download configuration file, user name access system. SW-RingTM: Single, Couple, Chain, Dual homing ring. Serial device server: 4 port serial device sever, each port support 4pcs TCP or UDP session connection
Interface
100M Ethernet: 10/100Base-TX self-adapt RJ45 port. 100M fiber port: 100Base-FX (SC/ST/FC) Console port: Procedure debug (RS-232), RJ45 Alarm port: 2 bit 7.62mm terminal block, 1 channel relay alarm output
Serial
RS-232 signal:TXD,RXD,RTS,CTS,DTR,DSR,GND RS-422 signal: T+, T-, R+, R-, GND RS-485 signal: D+, D-, GND Parity: None,Even,Odd,Space,Mark Data bit: 5bit,6bit,7bit,8bit Band rate; 300115200bps Direction control: RS485 side adopt ADDC technology, auto detect and control data transfer direction Loading: RS-485/422 side support 32 nodes loop back Protection: 2KV isolation, 15KV static protection. Connector: RS232: DB9 male, RS485/4225 bit terminal block
Transfer distance
Twisted cable: 100m(CAT5/CAT5e) Multi mode fiber: 1310nm,2Km Single mode fiber: 1310nm, 20K, 1310nm, 40Km 1310nm, 60K, 1550nm, 80Km RS-485/422: 1200m RS-232: 15m
Exchange attribute:
100M transmit speed: 148810pps Transfer: Store and forward System exchange bandwidth: 2.0G Buffer memory: 1MKbit Support 2K MAC address table
LED indicator
Power supply indicator: PWR Alarm indicator: Alarm System indicator: Run Ethernet port indicator: Link/Act(1-8) Serial port indicator: TX(1-4), RX(1-4)
Power supply
Input voltage: 24 VDC(12~48VDC) Terminal block: 4 bits 7.62mm terminal block IES618-4DRS-232-P(12/48VDC) None load consumption: 1.5 W@24VDC Full load consumption: 3.5 W@24VDC IES618-4DIRS-485-P(12/48VDC) None load consumption: 1.8 W@24VDC Full load consumption: 3.9 W@24VDC IES618-4F-4DIRS-485-P(12/48VDC) None load consumption: 4.8W@24VDC Full load consumption: 6.9W@24VDC IES618-2F-4DRS-232-P(12/48VDC) None load consumption: 3.2W@24VDC Full load consumption: 5.0W@24VDC IES618-2F-4DIRS-485-P(12/48VDC) None load consumption: 3.58W@24VDC Full load consumption: 5.35W@24VDC IES618-4F-4DRS-232-P(12/48VDC)
None load consumption: 4.75W@24VDC Full load consumption: 6.14W@24VDC Support dual redundant power supply
Support inside over-current 4.0A protection Support opposite connection protection
Mechanical
Shell: IP40, high strength iron shell. Installation: DIN Rail DimensionW×H×D: 160 mm×70mm×130mm Weight: 1021g
Environmental
Operating Temperature: -45°C to 75°C Storage Temperature: -45°C to 85°C Relative Humidity: 10 to 95% (non-condensing)
Standard
EMI: FCC Part 15, CISPR (EN55022) class A EMS: EN61000-4-2 (ESD), Level 4 EN61000-4-3(RS), Level 3 EN61000-4-4 (EFT), Level 4 EN61000-4-5 (Surge), Level 4 EN61000-4-6(CS), Level 3 EN61000-4-8(PFM), Level 5 Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32 Vibration: IEC 60068-2-6
Warranty
Warranty time: 5 years
Certification
CE, FCC, RoHS, UL508(Pending)
Loading...