SPECIFICATIONS
performance level for access control
This product complies with the following UL294 Access Control Performance
Levels:
Destructive AttackLevel 1
Line SecurityLevel 1
EnduranceLevel 4Prox
See the UL Listed access control unit controller installation instructions for reader
compatibility.
environmental
Operating Temperature-31°F to + 151°F (-35°C to +66°C)
Humidity86 ±3°F (85 ±5% at 30 ±2°C)
Ingress ProtectionIP65 (not evaluated by UL)
PositioningSuitable for OUTDOOR use.
electrical
Power supplyPower is to be provided by a UL294 Listed,
Voltage+10Vdc to +16Vdc
Current
3M Inline
3M Mullion
3M S-Gang
3M S-Gang Keypad
Data VoltageRest >4Vdc / Active <1Vdc
Data OutputWiegand, Clock & Data, Custom Outputs
Indication1 RGB LED
SounderIntegral speaker
3millID.com +1 303 475 4972
Specifications subject to change without notice.
©2017 3millID. All rights reserved.
100-02654-C
Level 1Bluetooth
low-voltage Class 2 power limited supply or
control panel, capable of 4 hours standby.
Idle and Peak current at 12VdcModelPart No.
Average
3MIL-R11030
3MIL-R11330
3MIL-R11320
3MIL-R11325
(+ RGB LED illuminated keypad to 3MIL-R11325)
15mA
41mA
41mA
62mA
Peak
35mA
82mA
82mA
100mA
dimensions
ModelSize - Inches ( millimetres )Part No.
3M Inline
3M Mullion
3M S-Gang
3M S-Gang Keypad
polymeric materials
Potting compoundUL R/C (QMFZ2)
MouldingsUL746C
wiringWiring methods shall be in accordance with
Recommended cableBELDEN 953x (or equivalent UL listed) for Wiegand.
Cable lengthUp to 492 feet (150 m) from controller.
Minimum
recommended wire sizeNot less than 24 AWG.
reader connectionsThese connections are common to all readers in
1-0VSupply voltage ground
2-+VdcSupply voltage (+10Vdc to +16Vdc)
3-DATA1/CLKWiegand or Clock/Data output
4-DATA0/DATWiegand or Clock/Data output
5-GREENGreen LED control input
6-REDRed LED control input
7-BuzzerBuzzer control input
8-TMPR/CPTamper or Card Present output
9-RS485-RS485 Bus
10-RS485+RS485 Bus
3MIL-R11030
3MIL-R11330
3MIL-R11320
3MIL-R11325
the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
BELDEN 9502 (or equivalent UL listed) for RS485.
All cable and wiring must be Listed and suitable for use.
the BD series.
3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )
3.8 x 2.1 x 0.8 in ( 96 x 52 x 21 mm )
4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )
4.7 x 3.0 x 0.8 in ( 120 x 76 x 21 mm )
3millID - 3M Inline
3MIL-R11030
125kHz
Supra®BT LE (2.4GHz)
3millID - 3M Mullion
3MIL-R11330
125kHz
13.56MHz
Supra®BT LE (2.4GHz)
3millID - 3M S-Gang
3MIL-R11320
125kHz
13.56MHz
Supra®BT LE (2.4GHz)
3millID - 3M S-Gang Keypad
3MIL-R11325
125kHz
13.56MHz
Supra®BT LE (2.4GHz)
Please turn over for installation guidance notes
These notes are provided as a general guidance for mounting, fixing and connecting 3millID - 3M series RFID
readers. Please consult your installer and the manufacturer’s details of your control panel, when configuring
your access security system.
GENERAL GUIDANCE NOTES to APPLIES TO ALL READER MODELS LISTED OVERLEAF
17
If fitted, remove reader module
1423
securing screw.
Position the reader module, ensuring
the top-edge fixing lugs engage
567
correctly with the recesses located at
the top of the backplate.
Pull bottom edge of reader module
away from the backplate, and lift up.
Swing the bottom edge of the module
down and forward until you feel the unit
click shut.
Mount the reader backplate to a flat
surface using suitable hardware having a
diameter no greater than 0.15 in (4mm).
Secure the reader module to the
backplate using the M3x100mm screw
as supplied.
If required, you may opt to
use security screw.
Once the backplate has been mounted, make wire connections to
the reader module in accordance with the screw terminal
connections shown below, and your control panel requirements.
Ensure the cable does not impair or prevent the reader module
being secured.
1-0VSupply voltage ground
2-+VdcSupply voltage (+10Vdc to +16Vdc)
3-DATA1/CLKWiegand or Clock/Data output
4-DATA0/DATWiegand or Clock/Data output
5-GREENGreen LED control input
6-REDRed LED control input
7-BuzzerBuzzer control input
8-TMPR/CPTamper or Card Present output
9-RS485-RS485 Bus
10-RS485+RS485 Bus
Applicable to 3M Inline add-on reader only. The following is a
diagrammatic representation of the wiring configuration providing a
4b
Bluetooth capabaility to most existing installations. Please consult
your installer and the manufacturer’s details of your existing control
panel and access control reader.
( THIS CONFIGURATION NOT EVALUATED BY UL )
10V
2+Vdc (+12Vdc)
3N/A
4N/A
5N/A
6N/A
7N/A
8N/A
9RS485 -
10RS485 +
line INline OUTpin
0V
+Vdc (+12Vdc)
N/A
N/A
N/A
N/A
N/A
N/A
RS485 -
RS485 +
line in from control panel
line IN
2AKUW-AV00
2AKUW-AV90
These devices comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
These devices contains: FCC ID: TCZ-10103751G1
EQUIPMENT
BP21018
RoHS
co mp li an t
Together with information provided by
suppliers and subcontractors, these devices
comply with the requirements and relevant
provisions of:
These RFID proximity readers comply with
the essential requirements and relevant
provisions of:
EU Directive 2011/65/EC.
EU Directive 2014/53/EC
This symbol on the product or on its packaging
indicates that the product must not be disposed of
with normal household waste. Instead, it is your
responsibility to dispose of your waste equipment
by arranging to return it to a designated collection
point for the recycling of waste electrical and
electronic equipment. By separating and recycling
your waste equipment at the time of disposal you
will help to conserve natural resources and ensure
that the equipment is recycled in a manner that
protects human health and the environment.
EU Directive 2012/19/EU
security
access
CONTROL
PANEL
3M Inline reader
line out from 3M Inline reader
1
2 3 4 5 6 7 8 910
line OUT
existing
ACCESS
CONTROL
READER
Loading...