3M Touch Screen Controller SC800 Reference Guide

3M
MicroTouch
Controller RX182
Reference Guide
Formerly
SC800 Serial Resistive
Read and understand all safety information
contained in this document before using this product.
3
3M Touch Systems, Inc. Proprietary Information
2 3M™ MicroTouch™ Controller RX182 Reference Guide
The information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of 3M Touch Systems, Inc. 3M may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. The furnishing of this document does not give you license to these patents, trademarks, copyrights, or other intellectual property except as expressly provided in any written license agreement from 3M Touch Systems, Inc.
The information provided in this document is intended as a guide only. For the latest detailed engineering specifications, please contact your 3M Touch Systems, Inc. Application Engineer. 3M Touch Systems, Inc. is committed to continually improving product designs. As a result, product specifications may be subject to change without notification.
"RoHS compliant 2005/95/EC" means that the product or part does not contain any of the following substances in excess of the following maximum concentration values in any homogeneous material, unless the substance is in an application that is exempt under RoHS: (a) 0.1% (by weight) for lead, mercury, hexavalent chromium, polybrominated biphenyls or polybrominated diphenyl ethers; or (b) 0.01% (by weight) for cadmium. This information represents 3M’s knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M.
NOTICE: Given the variety of factors that can affect the use and performance of a 3M Touch Systems, Inc. product (the
“Product”), including that solid state equipment has operation characteristics different from electromechanical equipment, some of which factors are uniquely within User’s knowledge and control, it is essential that User evaluate the 3M Touch Systems, Inc. Product and software to determine whether it is suitable for User’s particular purpose and suitable for User’s method of application. 3M Touch Systems, Inc. statements, engineering/technical information, and recommendations are provided for User’s convenience, but their accuracy or completeness is not warranted. 3M Touch Systems, Inc. products and software are not specifically designed for use in medical devices as defined by United States federal law. 3M Touch Systems, Inc. products and software should not be used in such applications without 3M Touch Systems, Inc. express written consent. User should contact its sales representative if User’s opportunity involves a medical device application.
IMPORTANT NOTICE TO PURCHASER: Specifications are subject to change without notice. These 3M Touch Systems,
Inc. Products and software are warranted to meet their published specifications from the date of shipment and for the period
stated in the specification. 3M Touch Systems, Inc. makes no additional warranties, expre ss or implie d, including but not limited to any implied warranties of merchantability or fitness for a particular purpose. User is responsible for determining
whether the 3M Touch Systems, Inc. Products and software are fit for User’s particular purpose and suitable for its method of production, including intellectual property liability for User's application. If the Product, software or software media is proven not to have met 3M Touch Systems, Inc. warranty, then 3M Touch Systems, Inc. sole obligation and User’s and Purchaser’s
exclusive remedy, will be, at 3M Touch Systems, Inc. option, to repair or replace that Product quantity or software media or to
refund its purchase price. 3M Touch Systems, Inc. has no obligation under 3M Touch Systems, Inc. warranty for any Product, software or software media that has been modified or damaged through misuse, accident, neglect, or subsequent manufacturing
operations or assemblies by anyone other than 3M Touch Systems, Inc. 3M Touch Systems, Inc. shall not be liable in any
action against it in any way related to the Products or software for any loss or damages, whether non-specified direct, indirect, special, incidental or consequential (including downtime, loss of profits or goodwill) regardless of the legal theory asserted.
© 3M 2004-2009 All rights reserved. Document Title: 3M
TM
MicroTouchTM Controller RX182 Reference Guide
Document Number: 19-272, Version 22
3M, the 3M logo, MicroTouch, and the MicroTouch logo are either registered trademarks or trademarks of 3M in the United States and/or other countries.
Windows and/or other Microsoft products referenced herein are either registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries.
All other trademarks are the property of their respective owners.
3M Touch Systems, Inc. Proprietary Information
3M™ MicroTouch™ Controller RX182 Reference Guide 3
Contents
Introduction
What You Need to Know ............................................................................................5
Important Safety Information......................................................................................5
3M Touch Systems Support Services..........................................................................6
Contact 3M Touch Systems ........................................................................................7
Chapter 1 Integrating the RX182 Controller
Overview of the RX182 Controller .............................................................................9
Handling and ESD Protection ...................................................................................10
Establishing the Data Connection .............................................................................10
Mounting the Controller............................................................................................11
Supplying Power to the Controller............................................................................11
Mounting the Sensor .................................................................................................12
Sensor Cable Connector ............................................................................................12
Status Light (LED) Diagnostics ................................................................................13
Turning On Your System ..........................................................................................13
Installing 3M™ MicroTouch™ Software .................................................................14
Chapter 2 RX182 Controller Communications
Controller Default Settings........................................................................................15
Communicating with the Controller..........................................................................16
Firmware Commands ................................................................................................18
Calibrate 3 Point........................................................................................................19
Guidelines for the C3 Commands .............................................................................20
Enter Sleep ................................................................................................................21
Format Tablet ............................................................................................................21
Get Controller Number..............................................................................................22
Mode Stream .............................................................................................................22
Null Command ..........................................................................................................23
Output Identity ..........................................................................................................23
Reset ..........................................................................................................................23
3M Touch Systems, Inc. Proprietary Information
4 3M™ MicroTouch™ Controller RX182 Reference Guide
Restore Defaults ........................................................................................................24
Set Controller Number ..............................................Error! Bookmark not defined.
Unit Type...................................................................................................................24
Appendix A RX182 Controller Specifications
Technical Specifications............................................................................................28
Storage and Operating Temperature with Humidity Conditions...............................29
3M Touch Systems, Inc. Proprietary Information
3M™ MicroTouch™ Controller RX182 Reference Guide 5
Introduction
3M Touch Systems offers several advanced controllers designed for reliability and easy installation. Each controller provides superior performance and delivers excellent stability, sensitivity, accuracy, and fast response.
This reference guide, designed for developers of touch systems, provides installation and configuration information for the 3M™ MicroTouch™ RX182 controller. This document includes information on integrating the RX182 controller into your design, communicating with the controller, installing the MT 7 software user interface, and troubleshooting setup problems. It also includes a complete description of the firmware commands and controller specifications.
3M Touch Systems is committed to being a premier supplier in touch systems throughout the world. As a 3M Touch Systems customer, you are aware that we have strong internal programs that meet or exceed environmental regulations of our customers and the regions in which we conduct business.
What You Need to Know
This document assumes you are familiar with firmware commands and how to use them. Executing some commands may alter the performance of your touch product. You should be aware of the results of using these commands before executing them.
Important Safety Information
Read, understand and follow all safety information before using this product. Follow all instructions marked on the product and described in this document. Pay close attention to the following installation warnings and safety precautions.
Intended Use
The RX182 controller was designed to enable touch in conjunction with other 3M™ MicroTouch™ products. This controller is intended for internal mounting only and is not suitable for use in hazardous locations.
3M Touch Systems, Inc. Proprietary Information
6 3M™ MicroTouch™ Controller RX182 Reference Guide
Explanation of Signal Word Consequences
WARNING: Indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury and/or property damage.
CAUTION: Indicates a potentially hazardous situation, which, if not avoided,
may result in minor or moderate injury and/or property damage.
CAUTION: Indicates a potentially hazardous situation, which, if not avoided, may
result in property damage.
WARNING
To reduce the risk of fire and/or explosion which could result in serious injury or death:
Do not install or use this product in a hazardous location.
To reduce the risk of fire and/or explosion which could result in serious injury or property damage:
Do not use this product in any outdoor environment unless NEMA standards (or similar standards such as IP rating) are followed.
To avoid the risk of electric shock which could result in serious injury or death:
Do not use a damaged power supply.
Do not use a power cord that is frayed or otherwise damaged.
CAUTION
To reduce the risks associated with improper disposal, which if not avoided may result in minor or moderate injury from ground water contamination:
Dispose of components in accordance with federal, state and local regulations.
To reduce the risk of possible environmental contamination which may result in minor or moderate injury:
Dispose of the display in accordance with federal, state and local regulations.
To reduce the risk of the potentially hazardous situations associated with the use of isopropyl alcohol which may result in minor or moderate injury or property damage:
Follow all instructions and recommendations in the manufacturer's Material Safety Data Sheet and product label.
3M Touch Systems Support Services
3M Touch Systems provides extensive support services through our website and technical support organization. Visit the 3M Touch Systems website at
http://www.3M.com\touch
regularly updated technical documentation on 3M™ MicroTouch™ products, and learn more about our company.
3M Touch Systems, Inc. Proprietary Information
, where you can download touch software and drivers, obtain
3M™ MicroTouch™ Controller RX182 Reference Guide 7
Whenever you contact Technical Support, please provide the following information:
Display size, part number and serial number
Current driver version
Operating system used
Information on additional peripherals
Technical Support is available Monday through Friday 8:30 a.m. to 5:30 p.m. with limited call back service after 5:30 p.m. until 8:00 p.m. US Eastern Standard Time – 9 a.m. to 5 p.m. throughout Europe.
You can contact 3M Touch Systems Technical Support (US only -- Eastern Standard Time) by calling the hot line, sending email or a fax.
Technical Support Hot Line: 978-659-9200
Technical Support Fax: 978-659-9400
Toll Free: 1-866-407-6666 (Option 3)
Email: US-TS-techsupport@mmm.com
Contact 3M Touch Systems
Contact information for all offices can be found on our website at:
http://www.3M.com\touch/
3M Touch Systems, Inc. Proprietary Information
3M™ MicroTouch™ Controller RX182 Reference Guide 9
CHAPTER 1
Integrating the RX182 Controller
The 3MTM MicroTouch™ RX182 serial resistive controller is an accurate, small outline, low cost, temperature stable controller capable of supporting a wide range of resistive sensors. It is designed for internal mounting in OEM applications.
This chapter covers the following RX182 controller specifications:
Cable connections
Mounting requirements
Power requirements and options
Status LED codes
Overview of the RX182 Controller
The RX182 controller is an uncased device using an RS-232 serial interface. The communication parameters for the RX182 are N81 -- no parity, 8 data bits, and 1 stop bit.
To integrate and test the RX182 controller, you need the following items:
A 8-wire resistive sensor.
A method of establishing the serial data communication between the controller and
your system. The standard 3M™ MicroTouch™ RS-232 plug and play serial cable (P/N 7319630) is recommended.
A power source.
A software utility or driver with a calibration routine.
Note: You can use MicroTouch™ Software, which includes the touch driver and
utilities software.
The controller measures 1.3 x 2.4 inches, or 1.6 x 2.7 inches total profile over the connectors. Allow additional clearance for the mating connectors. The total height profile is 0.40 inches from the thru hole pins on the trace side of the board to the top of the highest component on the opposite side. The RX182 has a 8-pin sensor connector (JP6), an 8-pin serial plug and play cable connector (JP2), and a 3-pin power connector for selectable input voltages.
3M Touch Systems, Inc. Proprietary Information
Loading...
+ 20 hidden pages