3M™ Scotch-Brite™ Products, Clean and Finish SVFN Discs, Sheets, Rolls, Brushes: PCCB, Flap Brushes, XDR, Bolt-Thru 04/30/14
__________________________________________________________________________________________
Page 6 of 9
11.1. Information on Toxicological effects
Signs and Symptoms of Exposure
Based on test data and/or information on the components, this material may produce the following health effects:
Inhalation:
Dust from cutting, grinding, sanding or machining may cause irritation of the respiratory system. Signs/symptoms may
include cough, sneezing, nasal discharge, headache, hoarseness, and nose and throat pain.
Skin Contact:
Mechanical Skin irritation: Signs/symptoms may include abrasion, redness, pain, and itching.
Eye Contact:
Mechanical eye irritation: Signs/symptoms may include pain, redness, tearing and corneal abrasion.
Dust created by grinding, sanding, or machining may cause eye irritation. Signs/symptoms may include redness, swelling,
pain, tearing, and blurred or hazy vision.
Ingestion:
No health effects are expected.
Carcinogenicity:
Ingredient C.A.S. No. Class Description Regulation
Carbon Black 1333-86-4 Grp. 2B: Possible human carc. International Agency for Research on Cancer
Quartz Silica 14808-60-7 Grp. 1: Carcinogenic to humans International Agency for Research on Cancer
SILICA, CRYS AIRRESP 14808-60-7 Known human carcinogen National Toxicology Program Carcinogens
Additional Information:
This document covers only the 3M product. For complete assessment, when determining the degree of hazard, the material
being abraded must also be considered.
This product contains titanium dioxide and quartz (crystalline) silica. Cancer of the lungs has been associated with inhalation
of high levels of titanium dioxide in animal studies, and occupational exposure to inhaled quartz silica has been associated
with silicosis and lung cancer. No exposure to titanium dioxide or quartz silica is expected during the normal handling and
use of this product. Titanium dioxide and quartz silica were not detected when air sampling was conducted during simulated
use of similar products containing these substances. Therefore, the health effects associated with titanium dioxide and quartz
(crystalline) silica are not expected during the normal use of this product.
Toxicological Data
If a component is disclosed in section 3 but does not appear in a table below, either no data are available for that endpoint or
the data are not sufficient for classification.
Acute Toxicity
Name Route Species Value
Overall product Ingestion No data available; calculated ATE > 5,000 mg/kg
Silicon Carbide Mineral Dermal Rat LD50 > 2,000 mg/kg
Silicon Carbide Mineral Ingestion Rat LD50 > 2,000 mg/kg
Filler Dermal Rat LD50 > 2,000 mg/kg
Filler Inhalation-
Dust/Mist
(4 hours)
Rat LC50 3.0 mg/l
Filler Ingestion Rat LD50 6,450 mg/kg
Quartz Silica Dermal LD50 estimated to be > 5,000 mg/kg
Quartz Silica Ingestion LD50 estimated to be > 5,000 mg/kg
Carbon Black Dermal Rabbit LD50 > 3,000 mg/kg
Carbon Black Ingestion Rat LD50 > 8,000 mg/kg
ATE = acute toxicity estimate