3M AV-3000 HT Instruction Manual

3M
Scott AV-3000 HT Facepiece
AV-3000 HT Facepiece
Enhanced thermal performance
The 3M™ Scott™ AV-3000 HT facepiece meets all requirements established in the NFPA 1981, 2018 Edition standard as a component of the SCBA, with advanced material technology to provide enhanced thermal durability and voice intelligibility performance for improved user safety.
All AV-series facepieces are designed for Top-Down Convertibility. This means you
can use a single facepiece with a single t
test for all of your NIOSH, CBRN and NFPA–approved respirators. (Some approvals pending).
High Performance Lens and Bezel
High performance materials in the lens and bezel meet the rigorous requirements laid out in NFPA 1981, 2018 Edition. These new materials enhance wearer safety when
exposed to high heat and ame loads.
Backward Compatibility
Approved for use with the latest Air-Pak X3 Pro SCBA, the AV-3000 HT facepiece also provides backward compatibility for use with older model Air-Pak SCBA meeting the 2013 Edition, 2007 Edition, and 2002 Edition of the NFPA 1981 standard.
Improved Voice Intelligibility
Redesigned voice communication components deliver outstanding voice intelligibility, exceeding the requirements of NFPA 1981, 2018 Edition. The dual voicemitters provide a sphere of intelligibility to those around the wearer, not just those directly in front.
Congured to meet your
needs
Available in a 4-strap or 5-strap headnet
Compatible with full line of EPIC 3 communications devices
Compatible with award-winning 3M ScottTM Sight In-Mask Thermal Imager
TM
AV-3000 HT Facepiece
Multiple headnet congurations - 4-strap and 5 strap
Integrated grab handle to assist with donning
ANSI/ISEA Z87.1-2010 Std., impact rated; Z87+
Utilizes proven SureSeal technology for enhanced
comfort, t and performance
High performance lens and bezel for improved thermal performance
Color contrasting inhalation valves for ease-of-inspection
Right or left communications bracket
Approved Congurations
Air-Pak SCBA Air-Purifying Respirator Supplied Air Respirator
Dual voicemitters for enhanced voice transmission around the wearer
Single facepiece for multiple applications
Reduces t-testing, cost and training
Lower total cost of ownership
AV-3000 HT Facepiece
Specications and Ordering information
AV-3000 HT Facepiece (with Kevlar Head Harness, 5-Strap)
Part Numbers Part Numbers Part Numbers Description
No Comm Bracket Right Comm Bracket Left Comm Bracket
201215-01 201215-04 201215-07 AV-3000 HT Small
201215-02 201215-05 201215-08 AV-3000 HT Medium
201215-03 201215-06 201215-09 AV-3000 HT Large
AV-3000 HT Facepiece (with Kevlar Head Harness, 4-Strap)
Part Numbers Part Numbers Part Numbers Description
No Comm Bracket Right Comm Bracket Left Comm Bracket
201215-21 201215-27 201215-34 AV-3000 HT Small
201215-22 201215-28 201215-35 AV-3000 HT Medium
201215-23 201215-29 201215-36 AV-3000 HT Large
Adapters
Part Number Description
XP-1008-4113-7 AV-632 Bayonet Adapter, 5 per box (compatible with 3M cartridges and lters)
805059-01 40mm Cartridge Adapter (for use with 40mm cartridges and lters)
200423-02 40mm First Responder Adapter (for use with AV-3000 HT and CBRN Cap-1 canister or 40mm cartridges and lters)
*70070406544 3M™ Fit Test Adapter 601 (for t testing with 3M lters using AV-632 Bayonet Adapter)
805628-01 40mm Quantitative Fit Test Adapter (for t testing with 40mm cartridge adapter and 40mm lter)
Other Accessories
Part Number Description
Comm Bracket Kits
201210-01 Comm Bracket Kit, Right (AV-3000 HT only)
201210-02 Comm Bracket Kit, Left (AV-3000 HT only)
Eyeglass Kits
805753-01 AV-3000 Series Standard Eyeglass Kit
200372-52F 52mm Wire Frame Eyeglass Kit
200371-60F 60mm Wire Frame Eyeglass Kit
Storage
805534-01 Fleece Facepiece Bag
*Must be ordered through 3M bCom
3M Scott Fire & Safety
Personal Safety Division Monroe Center, P.O. Box 569 Monroe, NC 28111
This design platform, pioneered by 3M Scott, allows one facepiece to be used in numerous respiratory protection
assemblies, from supplied air to air purication. This one-facepiece concept reduces the cost of inventory, training and t testing multiple facepieces for each employee.
Phone 1-800-247-7257 Email US-3M-ScottMonroeCSR@mmm.com Web 3MScott.com
HS7188 Rev E_EN 10/20 ISO 9001 Registered. Please recycle. Printed in USA © 3M 2020. All rights reserved. 3M and Scott are trademarks of 3M.