3M 6000 User Manual

Half and Full Facepiece Respirators 6000 Series, Reusable
Unmatched performance and comfort.
3M™ Half and Full Facepiece Respirators 6000 Series, Reusable offer the user comfort and convenience coupled with the cost savings of a reusable respirator.
Features/Benefits
• Used with 3M
Filters and Cartridges, these respirators are among the lightest available
• The swept back design of the cartridges improves balance and visibility
• Remarkably comfortable, soft, lightweight facepiece and easy-to-adjust head straps
• Reusable — just dispose of the cartridges/filters when used to capacity
• The half facepiece design is available with a standard and drop down head harness
• Can be disassembled, cleaned and reused
• NIOSH approved for negative pressure air purifying and positive pressure dual airline applications
• Supplied with reclosable storage bag
• The half and full facepieces are each available in 3 sizes (small, medium, large) to comfortably fit many faces
The 6000 Series respirators can be used in dual airline mode:
• Available with both back­mounted and front-mounted breathing tubes
Systems can be used in combination
with NIOSH
approved 3M
2000 Series Filters or 6000 Series Cartridges and P100 Filter/Cartridges
• Cartridge/filter connections provide negative and positive pressure capability in one respirator assembly
• Can be used on both high and low pressure systems*
• Wearer can disconnect the airline at the air regulating valve and the system is changed to a filters/ cartridges air purifying mode — then back to supplied air system with a simple reconnection of the airline
• Small diameter breathing tubes are simple to work with and easy to clean and decontaminate
4017
page 1 of 4
3
The 3M™ Half and Full Facepiece Respirators 6000 Series, Reusable with replaceable cartridges/filters
3
These respirators help reduce exposure to certain airborne contaminants. Misuse may result in sickness or death. Before use, the wearer must read and understand User Instructions provided as a part of product packaging.Time use limitations may apply. For proper use, see supervisor, packaging or call 3M OH&ESD Technical Service, call 1-800-243-4630. In Canada, call 1-800-267-4414 or 1-800-265-1840, ext. 6137.
WARNING
!
Issue Date 03/24/03
* Employer must provide a minimum of Grade D breathing air in accordance with OSHA requirements.
3
3
3
3
3M™Half and Full Facepiece Respirators 6000 Series, Reusable
4017
page 2 of 4
Half Facepieces
6100/07024 Small 6200/07025 Medium 6300/07026 Large
Half Facepieces Drop Down
6100DD Small 6200DD Medium 6300DD Large
3MTMFilters and Accessories 2000 Series, 7093, 5N11, 5P71
2071
P95
particulate
filter
2076HF
P95 filter with
hydrogen fluoride,
nuisance level
acid gas relief*
2078
P95 filter with
nuisance level
organic vapor and
acid gas relief*
2091/07000
P100
particulate
filter
2096
P100 filter
with nuisance
level acid
gas relief*
2097/07184
P100 filter
with nuisance
level organic
vapor relief*
3
2
0
7
1
3
2
0
7
1
11J6200 NIOSH
P95
3
2
0
9
1
3
2
0
9
1
P100
11J6200
NIOSH
7093
P100
particulate
filter
5N11
N95 filter
(use with the 501
filter retainer)
5P71/07194
P95 filter
(use with the 501
filter retainer)
501
filter retainer
(use with the 5N11
and 5P71 filters)
502
filter adapter
(use with the 2000
Series and 7093 filters)
*Nuisance levels refer to concentrations below the OSHA PEL.
Full Facepieces
6700 Small 6800 Medium 6900 Large
Full Facepieces DIN
6700DIN Small 6800DIN Medium 6900DIN Large
0
7
2
8
3
P95
11J6200
3
NIOSH
8
2
7
0
0
7
2
6
H
F
P95
3
3
HYDROGEN FLUORIDE
F
00J0000
H
NIOSH
6
2
7
0
2
0
9
6
3
P100
J6200
11
3
NIOSH
6
9
0
2
3
PART NO.
1
50
0
2
9
7
3
P100
11J6200
3
NIOSH
7
9
2
0
3
O.
N
RT
PA
502
E
V
O
EM
R
T
O
O N
D
E
G
ID
R
RT
A
C
M
O
R
F
3M™Half and Full Facepiece Respirators 6000 Series, Reusable
4017
page 3 of 4
Accessories
6878 Spectacle Kit 6885 Face Shield Cover 6886 Tinted Lens Cover
Replacement Parts
7883 Neck Strap Assembly 6889 Exhalation Valve 6892 Center Adapter Assembly 6893 Inhalation Valve 6894 Nose Cup Assembly 6895 Inhalation Gasket 6896 Center Adapter Gasket 6897 Head Harness Assembly 6898 Lens Assembly 6899 Lens Frame Kit
Full Facepiece Replacement Parts and Accessories 6000 Series
Product Number NIOSH Approval*
6001 Certain organic vapors (a)(b)
6002 Chlorine, hydrogen chloride, and
sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b)
6003 Certain organic vapors, chlorine,
hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride (a)(b)
6004 Ammonia and methylamine (a)(b)
6005 Formaldehyde and certain organic
vapors (a)(b)(c)
6006 Certain organic vapors, chlorine,
hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde or hydrogen fluoride
(a)(b)(c)
6009 Mercury vapor or chlorine gas (a)(b)
* For respiratory protection against the following contaminants up to 10X PEL with half facepiece respirators or 50X PEL
with full facepiece respirators when quantitatively fit tested.
(a)
All respirators and respirator/filter assemblies can be used up to the NIOSH approval limits, 10X PEL for half facepiece respirators or 50X PEL for full facepiece respirators or the maximum use concentration allowable in applicable OSHA standards, whichever is lower.
(b)
For specific usage, limitations and warning information, see respirator and/or filter packaging, or call 3M OH&ESD Technical Service 1-800-243-4630. In Canada, call 1-800-267-4414.
(c)
OSHA regulations require that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
(d)
As recommended by the California Department of Pesticide Regulation no. 01-099 Methyl Bromide Field Fumigation.
Product Number NIOSH Approval*
60921 P100/Certain organic vapors (a)(b)
60922 P100/Chlorine, hydrogen chloride,
and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b)
60923
P100/Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride (a)(b)
60924 P100/Ammonia and methylamine (a)(b)
60925 P100/Formaldehyde and certain
organic vapors (a)(b)(c)
60926 P100/Certain organic vapors,
chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c)
60928 P100/Organic Vapor/Acid Gas (d)
60929 P100/Mercury vapor or chlorine
gas (a)(b)
Replacement Parts
6281 Respirator Strap Assembly 6889 Exhalation Valve
Half Facepiece Replacement Parts 6000 Series
Half Facepiece 6000 Series
Facepieces Facepieces
per bag per case
124
Full Facepiece 6000 Series
Facepieces Facepieces
per box per case
14
6893 Inhalation Valve 6895 Inhalation Gasket
Note: For more information on 3M™ Dual Airline Supplied Air Systems, please call 3M’s Fax On Demand line at 1-800-646-1655 and order document number 4024.
High Low
Accessories and replacement parts Pressure Pressure
Standard Back-Mounted Adapter Kit. Includes SA-2500 Breathing Tube, GVP-127 SA-2000 SA-2000LP Belt and SA-1009 Air Regulator or SA-1029 Connector (low pressure).
Combination Back-Mounted Adapter Kit. Includes 2600 Breathing Tube, GVP-127 Belt SA-2100 SA-2100LP and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
Standard Front-Mounted Adapter Kit. Includes SA-1500 Breathing Tube, GVP-127 Belt, SA-1000 SA-1000LP and SA-1009 Regulator or SA-1029 Connector (low pressure).
Combination Front-Mounted Adapter Kit. Includes SA-1600 Breathing Tube, GVP-127 Belt, SA-1100 SA-1100LP and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
To complete a 3M™Dual Airline Respirator System, select a facepiece, an adapter kit and an air supply hose.
For example: 6800 + SA-2000 + W-9435-100 = complete system.
3M™Half and Full Facepiece Respirators 6000 Series, Reusable
4017
page 4 of 4
3M Occupational Health and Environmental Safety Division
3M Center, Building 235-2W-70 St. Paul, MN 55144-1000
For more Information:
In the U.S., contact:
Technical Assistance
1-800-243-4630
Sales Assistance/Local Distributor
1-800-328-1667
Fax On Demand
1-800-646-1655
Internet
www.3M.com/occsafety
E-mail
occsafety@mmm.com
For other 3M products
1-800-3M HELPS
In Canada, contact:
3M Canada Company, OH&ESD P.O. Box 5757 London, Ontario N6A 4T1
Technical Assistance (Canada only)
1-800-267-4414
Sales Assistance
1-800-265-1840, ext. 6137
Fax On Demand
1-800-646-1655
Internet
www.3M.com/CA/occsafety
3M Canada E-mail
ohes@ca.mmm.com
Technical Assistance In Mexico
01-800-712-0646 5270-2255, 5270-2119 (Mexico City only)
Technical Assistance In Brazil
0800-132333
Fax On Demand OUS Locations
1-651-732-6530
3M™Fit Test Respirator
3M developed this product specifically for quantitative fit testing. Available in small (6100Q), medium (6200Q) and large (6300Q). A probe has been added for fit testing purposes. Do not use for
respiratory protection.
3
3M™Quantitative Fit Test Adapter 601
For use with all 3M bayonet attachment facepieces.
3M
Fit Test Kits
• FT-10 Qualitative Fit Test Apparatus (sweet solution)
• FT-20 Training and Fit Testing Case (sweet solution)
• FT-30 Qualitative Fit Test Apparatus (bitter solution)
E