3M Shielded/Jacketed, Flat Cable
.050″ 28 AWG Stranded, PVC/PVC 3517 Series
S Meets external wiring requirements of
National Electrical Code, Article 725 (CL2)
S UL listed for USA and Canadian markets
S 28 AWG stranded wire on .050 inch centers
permits mass termination to broad line of IDC
connectors
S 360 degree expanded copper shielding provides
20 db average shielding effectiveness
S Primary cable is zippable for branching or
discrete terminations
Date Modified:May 30, 2003
TS-0069-18
Sheet 1of 2
Physical
Jacket
Material: Polyvinyl Chloride (PVC)
Color: Black
Primary Material: PVC
Color: Gray
Marking
Standard:
Conductors: 28 AWG 7 × 36 [ 7× 0.127 ] Tinned Stranded Copper
Shielding Material: Expanded Copper
(UL) CL2 75C 28 AWG OR AWM 20879 3M NU
EU <50V
C
AWM IIA/B 80C 300VFT1
Electrical
Voltage Rating: USA: N.E.C. 725, CL2 or AWM 300V Canada: 300V EU: <50V
10
Insulation Resistance: (Primary Cable) >1 × 10
Unbalanced Balanced
Characteristic Impedance: 70 Ω 119 Ω
Capacitance: 21.5 pF/ft (70.5 pF/m) 12.7 pF/ft (41.7 pF/m)
Inductance: .11 µH/ft (0.36 µH/m) .19 µΗ/ft (0.62 µΗ/m)
Propagation Delay: 1.51 ns/ft (4.95 ns/m) 1.51 ns/ft (4.95 ns/m)
Velocity of Propagation: 67% 67%
Note: Unbalanced is measured between ground-signal-ground conductors,with shield grounded. Balanced is measured between signal conductors
within a pair,with theshield floating.
Ω/10 ft. [ 3m ]
Environmental
Temperature Rating: USA: CL2; 75°CorAWM: --20°Cto+80°C Canada: 80°C
Flammability Rating: USA: N.E.C. 725, CL2 Canada: FT1
UL File No.: E118773, Power Limited Circuit Cable: CL2 (orAWM Style 20879)
3
Interconnect Solutions
http://www.3M.com/interconnects/
For technical, sales or ordering information call
3M is a trademark of 3M Company.
800-225-5373
3M Shielded/Jacketed, Flat Cable
.050″ 28 AWG Stranded, PVC/PVC 3517 Series
Number of
Conductors
3M Part
Number
Dimension A ± .04 Dimension B
09 3517/09 .58[14.7] 0.400 ± .007 [ 10.16 ]
10 3517/10 .63[16.0] 0.450 ± .007 [ 11.43 ]
14 3517/14 .83[21.1] 0.650 ± .007 [ 16.51 ]
15 3517/15 .88[22.4] 0.700 ± .007 [ 17.78 ]
16 3517/16 .93[23.6] 0.750 ± .011 [19.05 ]
20 3517/20 1.13 [ 28.7 ] 0.950 ± .011 [ 24.13 ]
24 3517/24 1.33 [ 33.8 ] 1.150 ± .011 [ 29.21 ]
25 3517/25 1.38 [ 35.0 ] 1.200 ± .011 [ 30.48 ]
26 3517/26 1.43 [ 36.3 ] 1.250 ± .011 [ 31.75 ]
30 3517/30 1.63 [ 41.4 ] 1.450 ± .015 [ 36.83 ]
34 3517/34 1.83 [ 46.5 ] 1.650 ± .015 [ 41.91 ]
36 3517/36 1.93 [ 49.0 ] 1.750 ± .015 [ 44.45 ]
37 3517/37 1.98 [ 50.3 ] 1.800 ± .015 [ 45.72 ]
R
40 3517/40 2.13 [ 54.1 ] 1.950 ± .015 [ 49.53 ]
50 3517/50 2.63 [ 66.8 ] 2.450 ± .015 [ 62.23 ]
60 3517/60 3.13 [ 79.5 ] 2.950 ± .015 [ 74.93 ]
64 3517/64 3.38 [ 85.9 ] 3.150 ± .015 [ 80.01 ]
A
B
.050 ± .002 Typ
[1.27]
.11± .03
[2.8]
Paper
(Mfgr. Option)
.005 [ 0.13 ] Ref
Expanded Copper
Note: Red marking on edge of primary cable designates wire #1.
Ordering Information
Note: Standard length is 100 ft/roll.
PVC Primary
Insulation
28 AWG 7 X 36 [ 7 X 0.127 ]
Tinned Stranded Copper Conductors
3517/XX
Number of Conductors
(See Table)
.026 Min (0.66)
PVC Jacket
Inch
[mm]
Tolerance Unless Noted
.0 .00 .000
Inch
[ ] Dimensions for
Reference only
TS-0069-18
Sheet 2 of 2
±.010±.1 ±.05
3
Interconnect Solutions
http://www.3M.com/interconnects/
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373