Register your stethoscope at www.littmann.com
GB English ................................................................................................................pp. 1-22
FR Français ............................................................................................................pp. 23-44
DE Deutsch .............................................................................................................pp. 45-66
IT Italiano ..............................................................................................................pp. 67-88
ES Español ...........................................................................................................pp. 89-110
NL Nederlands ....................................................................................................pp. 111-133
SE Svenska ........................................................................................................pp. 134-155
DK Dansk ............................................................................................................pp. 156-176
FI Suomenkielinen .............................................................................................pp. 177-197
NO Norsk ............................................................................................................pp. 198-219
PT Portugês ........................................................................................................pp. 220-243
GR Eλληνικά. .........................................................................................................pp. 244-265
3M™ Littmann® Electronic Stethoscope
Model 3200
With Ambient Noise Reduction
Introduction
Congratulations and thank you for choosing the 3M™ Littmann® Electronic Stethoscope Model 3200.
The Model 3200 brings you the very latest in advanced auscultation and wireless electronics technology in a highly
ergonometric and easy-to-use format.
The Model 3200’s combination of Ambient Noise Reduction technology, frictional noise dampening materials, electronic
amplifi cation (conventional bell / diaphragm modes plus an extended range mode), Bluetooth
user interface takes you to the next level of performance and ease of use.
Whether you are auscultating infant, pediatric or adult patients, in quiet or noisy environments, or picking up diffi cult-to-hear
heart and body sounds, you’ll appreciate the technology that’s been built into this latest electronic stethoscope bearing the
Littmann® brand.
Don’t miss the sounds you need to hear!
SAFETY INFORMATION
Please read, understand, and follow all safety information contained in these instructions prior to using this electronic
stethoscope. Retain these instructions for future reference.
U.S.A. ONLY
Caution: Federal law restricts this device to sale by or on the order of a physician.
Explanation of Safety Related Labels and Symbols
Indicates Type B Equipment: The equipment provides protection against electrical shock and electrical
current leakage. Applied parts are considered to be the complete chestpiece with diaphragm and binaural.
Consult instructions for use.
IPX4
Protected against splashing liquid (chestpiece only).
This product contains electrical and electronic components and must not be disposed of using standard
refuse collection. Please consult local directives for disposal of electrical and electronic equipment.
This product and packaging does not contain natural rubber latex.
® data transfer, and an all-new
GB English
AP
Indicates Category AP Equipment. Tested for use with fl ammable anesthetic mixture with air.
1
Explanation of Signal Word Consequences
CAUTION: Indicates a hazardous situation, which, if not avoided, could result in minor injury and/or property
NOTICE: Indicates a hazardous situation, which, if not avoided, may result in property damage.
GB English
• To reduce the risks associated with infection follow all cleaning and disinfecting instructions included in this
manual. Establish and follow a cleaning and disinfecting schedule.
• To reduce the risks associated with very strong electromagnetic fi elds avoid using the stethoscope near
strong radio frequency signals or portable and/or mobile RF devices. If you hear sudden or unexpected sounds,
move away from any radio transmitting antennas.
• To reduce the risks associated with sharp edges make sure that the soft sealing eartips are snapped fi rmly
into position as shown in this manual. Use only Littmann replaceable eartips.
• To reduce the risks associated with an incorrect result store and operate this stethoscope only as instructed
in this manual. As there is no acoustic (non-amplifi ed) mode available with this stethoscope, replace the battery
within two hours of the battery life icon beginning to fl ash in the LCD display. Replace battery with only type AA.
Also, do not immerse the stethoscope in a liquid or subject it to any sterilization processes.
• To reduce the risk associated with an electrical shock do not use the stethoscope on patients without the
stethoscope’s diaphragm cover in place.
• The Model E3200 Electronic Stethoscope contains a Bluetooth Class 2 wireless data link. This radio
frequency data link operates at a frequency of 2.4 GHz using GFSK modulation and with a maximum transmit
power of 2.5 mW (0.00250 watts). The maximum radio frequency fi eld strength generated by the stethoscope
is below three volts per meter, a level that is considered safe to use with other medical devices. However, if
electromagnetic interference is encountered due to the Bluetooth wireless data link, immediately move the
stethoscope away from that device and/or turn the Bluetooth feature OFF.
damage.
CAUTION
NOTICE
• To reduce the risks associated with environmental contamination follow applicable regulations when
disposing of this stethoscope. Properly dispose of, or recycle, spent batteries.
• No modifi cation of this equipment is allowed. Use only authorized 3M service personnel to repair this
stethoscope. Read, understand, and follow all the safety information on the battery package.
EMC Compliance
FCC Intentional Radiator Certifi cation
3M Littmann Electronic Stethoscope Model 3200
FCC ID: DGFIPD3200
This equipment contains an intentional radiator approved by the FCC under the FCC ID numbers shown above. This device
complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesirable operation.
NO MODIFICATION: Modifi cations to this device shall not be made without the written consent of the 3M Company.
Unauthorized modifi cations may void the authority granted under Federal Communications Commission rules permitting the
operation of this device.
Industry Canada radio frequency rules and regulations
IC: 458A-IPD3200
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
EMC compliance Europe
This equipment complies with the EMC requirements of the IEC 60601-1-2.
Intended Use
The 3M™ Littmann® Electronic Stethoscope Model 3200 is intended for medical diagnostic purposes only. It may be used
for the detection and amplifi cation of sounds from the heart, lungs, arteries, veins, and other internal organs with the use of
selective frequency ranges. It can be used on any person undergoing a physical assessment.
Operator Profi le
The 3M™ Littmann® Electronic Stethoscope Model 3200 is designed to be used by anyone who wishes to listen to sounds
as described in the Intended Use section above. This manual provides complete information on how to operate the Model
3200 so that no additional operating training is required.
Functional Description
The 3M™ Littmann® Electronic Stethoscope Model 3200 picks up sounds, such as heart and lung sounds, from a patient’s
body. After amplifi cation and fi ltering, the sounds are sent to the user through a binaural headset. The stethoscope chestpiece
is designed for use with adult, pediatric, and infant patients.
The user interface for the stethoscope includes a 5-button keypad and an LCD display. Sound processing is carried out
with the aid of a digital signal processor. Stethoscope power is provided by a single AA battery in the chestpiece. A power
management system is included to prolong battery life. Using its Bluetooth wireless link, the stethoscope can exchange audio
data with an external device such as a personal computer (PC).
GB English
2
3