3M 16 IR DATA SHEET

3M 316 IR
the connection by driving the cap down flush with the
Application:
Use 3M Brand 316 IR to electrically connect two or three wire ends, insulate the connection and provide a moisture resistant seal. Recommended for use with low energy underground circuit wires, Sprinkler System, Landscape Lighting or other moisture resistance wires for applications of less than 30 volts.
Wire Range:
22-16 AWG solid or stranded copper conductors with a maximum insulation of .160 inches.
Construction:
U-Contact Tin plated brass .02 inches (0.5 mm) thick Insulator Flame retardant nylon Black cap - White body
Temperature 105°C
Sealant Mineral oil base EG -3 grease
For Material Safety Data Sheet contact Elecuical Product Division/3M 3M Austin center, A145-4N-02 Austin, Tx. 78726-9000 (612)733 1110 Operator#55
Weight:
.0077 lb. (3.49 gm)
Recommended Installation Tool:
3M No. E-9BM Crimping tool or 8" Slip Joint Pliers
Installation Instructions:
CAUTION - Turn power off before installing connector. All
electrical work should be done according to appropriate electrical codes. Use with circuits less than 30 volts. Use with insulated copper conductors.
Do not strip insulation from conductors.
1. Insert 2 or 3 unstripped conductors completely into
connector and check their position by looking through the translucent body. Hold tool perpendicular to the conductors and make
2.
top edge of the connector body.
Engineering Specification:
A self-stripping electrical connector for connecting two or three conductors in the range of 22 thru 16 AWG solid or stranded copper conductors with a maximum insulation diameter of .160. This connector will he manufactured by 3M and provide a low voltage connection (less than 30 volts) that will be made in a pigtail application while providing a moisture resistant seal.
IMPORTANT NOTICE TO
of the Seller which are not contained
implied warranties of merchantability
PURCHASER: All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its inteded use. The user assumes all risks and liability whatsoever in connection with such use.
3M Electrical Products Division
6801 River Place Blvd. Austin, Texas 78726 - 9000
All statements or recommendations in the Seller's current publications
shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties expressed or implied, including but not limited to the
and fitness for a particular purpose which warranties are hereby
expressly disclaimed.
3M 1993
10/5/93
SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECTOR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS.
3M
Loading...