the connection by driving the cap down flush with the
Application:
Use 3M Brand 316 IR to electrically connect two or three
wire ends, insulate the connection and provide a moisture
resistant seal. Recommended for use with low energy
underground circuit wires, Sprinkler System, Landscape
Lighting or other moisture resistance wires for applications
of less than 30 volts.
Wire Range:
22-16 AWG solid or stranded copper conductors with a
maximum insulation of .160 inches.
Construction:
U-Contact Tin plated brass .02 inches (0.5 mm) thick
Insulator Flame retardant nylon Black cap - White body
Temperature 105°C
Sealant Mineral oil base EG -3 grease
For Material Safety Data Sheet contact Elecuical Product
Division/3M
3M Austin center, A145-4N-02 Austin, Tx.
78726-9000 (612)733 1110 Operator#55
Weight:
.0077 lb. (3.49 gm)
Recommended Installation Tool:
3M No. E-9BM Crimping tool or
8" Slip Joint Pliers
Installation Instructions:
CAUTION - Turn power off before installing connector. All
electrical work should be done according to appropriate
electrical codes.
Use with circuits less than 30 volts.
Use with insulated copper conductors.
Do not strip insulation from conductors.
1. Insert 2 or 3 unstripped conductors completely into
connector and check their position by looking
through the translucent body.
Hold tool perpendicular to the conductors and make
2.
top edge of the connector body.
Engineering Specification:
A self-stripping electrical connector for connecting two or
three conductors in the range of 22 thru 16 AWG solid or
stranded copper conductors with a maximum insulation
diameter of .160. This connector will he manufactured by
3M and provide a low voltage connection (less than 30 volts)
that will be made in a pigtail application while providing a
moisture resistant seal.
IMPORTANT NOTICE TO
of the Seller which are not contained
implied warranties of merchantability
PURCHASER:
All statements, technical information
and recommendations related to the
Seller's products are based on
information believed to be reliable,
but the accuracy or completeness
thereof is not guaranteed. Before
utilizing the product, the user should
determine the suitability of the
product for its inteded use. The user
assumes all risks and liability
whatsoever in connection with such
use.
3M Electrical Products
Division
6801 River Place Blvd.
Austin, Texas 78726 - 9000
All statements or recommendations
in the Seller's current publications
shall have no force or effect unless
contained in an agreement signed
by an authorized officer of the
Seller. The statements contained
herein are made in lieu of all
warranties expressed or implied,
including but not limited to the
and fitness for a particular purpose
which warranties are hereby
expressly disclaimed.
3M 1993
10/5/93
SELLER SHALL NOT BE LIABLE TO
THE USER OR ANY OTHER
PERSON UNDER ANY LEGAL
THEORY, INCLUDING BUT NOT
LIMITED TO NEGLIGENCE OR
STRICT LIABILITY, FOR ANY
INJURY OR FOR ANY DIRECTOR
CONSEQUENTIAL DAMAGES
SUSTAINED OR INCURRED BY
REASON OF THE USE OF ANY OF
THE SELLER'S PRODUCTS.
3M