Introduction
Introduction
Preface
Thank you for purchasing the IDEAL LIFE Communication Enabler™. This device allows you to use a third
party gluclose meter with the IDEAL LIFE Health Management System™. Using your third party glucose
meter in conjunction with the IDEAL LIFE Communication Enabler™, you’ll be able to measure your blood
glucose and manage information automatically so that you can work with your healthcare provider to
control your blood glucose.
Intended Use
The IDEAL LIFE Communication Enabler™ is intended to allow the use of a third party glucose meter in
obtaining a quantitative measurement of glucose in fresh capillary whole blood samples drawn from the
ngertip or alternative sites (palm, forearm, upper arm, calf, and thigh) and transmit them over the IDEAL
LIFE Health Management System™.
The IDEAL LIFE Communication Enabler™ and accompanying devices are intended for self-testing outside
the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of
diabetes control. The system is not to be used for the diagnosis of or screening for diabetes or for neonatal
use. Alternative site testing should only be done during steady state times when blood glucose is not
changing rapidly.
The IDEAL LIFE Communication Enabler™ can wirelessly communicate with a communication gateway or
an access point such as the IDEAL LIFE Pod ™or the IDEAL LIFE Gateway™ application.
Precautions
The IDEAL LIFE Communication Enabler™ should only be used with supported devices. Do not use the
IDEAL LIFE Communication Enabler™ with any other devices.
3Instruction Manual v7.0 Apr 2014
Package Contents
Package Contents
Communication Enabler™
IDEAL LIFE
INSTRUCTION MANUAL
GLUCOSE METER
CABLE
*May vary from image
shown
NOTE: Check your system to be sure that it is in working order and that it contains all parts listed above.
If either of these conditions is not met, please return your system to the place of purchase.
POWER
ADAPTER
4IDEAL LIFE Communication Enabler™ ICE0001
Before You Start
Before You Start
Your IDEAL LIFE Communication Enabler
Battery
Indicator Light
Power
Indicator Light
TM
Communication
Indicator Light
AAA Batteries
Power Button
Battery Cover
USB Port
Data Cable Port
Power Adapter Port
5Instruction Manual v7.0 Apr 2014
Using Your IDEAL LIFE Communication Enabler
™
™
Using Your IDEAL LIFE Communication Enabler
INSTALLING BATTERIES
The IDEAL LIFE Communication Enabler™ can be operated using 4 AAA batteries or a power adapter.
The Battery Indicator Light will light up when batteries need to be replaced.
• Remove the battery compartment door on your IDEAL LIFE Communication Enabler™ by lifting the
battery door using the notch.
• Place the batteries as instructed on the device.
• Replace the battery compartment door and click into place.
NOTE: Replacing the battery does not affect previous test results stored in memory of the device.
Use only new batteries of the required size and the recommended installation type. Alkaline batteries are
recommended for the best performance and battery life.
Do not mix different type, date or brand name batteries together. Be sure to follow the instructions when
installing the batteries. Batteries can leak chemicals that damage electronic parts. Leaving batteries inside
the device for long periods of time could cause damage to the device.
Please remove the batteries if you are not going to use the device for an extended period of time(i.e., 3
months or more). The batteries should be kept away from small children as they pose a choking hazard. If
swallowed, promptly see a doctor for help.
SENDING A MEASUREMENT
1. Connect one end of the Glucose Meter Cable to your third party blood glucose meter.
2. Connect the Power Adapter to the Power Adapter Port on the IDEAL LIFE Communication Enabler™.
3. Press the Power Button on the IDEAL LIFE Communication Enabler™ to turn the device on. The
Power Indicator Light should turn on. Do not push the Power Button repeatedly or hold it down for
long periods of time.
4. Plug your glucose meter’s cable into the Data Cable Port or USB Cable Port on the back of the IDEAL
LIFE Communication Enabler™. If your glucose meter’s cable does not t into either of these ports,
you will have to use one of the provided adapter cables.
Abbott Freestyle Freedom Lite Plug the Glucose Meter Cable into the Data Cable Port on the IDEAL LIFE Communication
Enabler™
Nipro TRUEresult Attach the USB Adapter to the other end of the Nipro cable. Then plug the cable into the USB port
on the IDEAL LIFE Communication Enabler™
6IDEAL LIFE Communication Enabler™ ICE0001
5. The Battery Indicator Light will blink green to let you know that your glucose meter has successfully
been connected to the IDEAL LIFE Communication Enabler™. The Communication Indicator Light will
blink blue to let you know that data is ready to be transferred.
6. Take your readings like you normally would using your glucose meter.
CLEARING DEVICE MEMORY
• To clear device memory, hold the Power Button for 5 seconds. The Battery Indicator Light will begin to
blink.
• Release the Power Button and hold it again for 5 seconds. The Battery Indicator Light and Power
Indicator Light will both begin to blink. The device’s memory is now cleared.
7Instruction Manual v7.0 Apr 2014
Specications
Specications
IDEAL LIFE Communication Enabler™ICE0001
Model: IDEAL LIFE Communication Enabler™ ICE0001
Display: LEDs
Power Source: AC/DC 6V 2W adapter
4 x 1.5 V “AAA” alkaline batteries
Operating Temperature/Humidity: 50°F to 104°F (10°C to 40°C)/Below 85% relative humidity
Storage Temperature/Humidity: 23°F to 122°F (-5°C to 50°C)/Below 90% relative humidity
Console Weight: Approx. 2oz
Outer Dimensions: Approx. 90mm Width x 85mm Depth x 22mm Height
Note: These specications are subject to change without notice.
CAUTION!
Do not attempt to open the device or to remove any components. Servicing should be done by qualied
technicians only.
Care And Maintenance
The IDEAL LIFE Communication Enabler™ requires care to keep the device clean and dry. Wipe the
outside with a cloth dampened with water and mild detergent or glass cleaner. Handle with care.
8IDEAL LIFE Communication Enabler™ ICE0001
FCC Statement
FCC Statement
Interference Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV technician for help.
FCC CAUTION:
To assure continued compliance, any changes or modications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment. (Example - use only
shielded interface cables when connecting to computer or peripheral devices).
IMPORTANT NOTE:
To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must
be installed to provide a separation distance of at least 20cm from all persons and must not be colocated
or operating in conjunction with any other antenna or transmitter.” This device complies with part 15
of the FCC rules. Operation is subject to the following two conditions (1) This device may not cause
harmful interference and (2) This device must accept any interference received, including interference
that may cause undesired operation.
WARNING:
Changes or modications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
9Instruction Manual v7.0 Apr 2014
Service Requirements
Service Requirements
In the event of equipment malfunction, all repairs should be performed by our Company or an
authorized agent. It is the responsibility of the User to report the need for service to our Company or
authorized agent. Please refer to the original location of purchase for service details.
10IDEAL LIFE Communication Enabler™ ICE0001
IDEAL LIFE US INC.
Customer Support Hours: Between 9:00 am and 8:00 pm (EST)
Tel 1-866-IDEAL-41 1-866-433-2541 www.IDEALLIFEonline.com
At all other times, you should contact your healthcare professional for assistance.