Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.03 Page 1 of 16
Zip HydroTap Miniboil
Boiling and Ambient drinking water for kitchens and the home.
®
Installation and Operating Instructions
Affix Model Number Label Here
89585
Miniboil BA tap
HydroTap Classic BA tap
Page 2 of 16 Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.03
This page intentionally left blank
Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.03 Page 3 of 16
Before Installation:
A. Read the instructions.
B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied.
C. The pressure limiting valve must be fitted as part of the kit.
D. Check the water quality to determine if extra filtration will be required.
E. Check the appliance rating plate and ensure correct power is available for the appliance.
F. Check the underbench cupboard supporting the appliance is adequate for
the total weight of the appliance, when full of water.
Before Commissioning:
1. Check the unit has been secured correctly.
2. Flush the supply line before connecting.
3. Check all plumbing fittings have been tightened.
4. Ensure the outlet and vent pipes are positioned to drain correctly.
5. For undersink units ensure there is adequate ventilation.
6. Check all tubes from the undersink unit to the tap, have a constant rise and there are no ‘S’
traps or kinks in the hoses.
7. Check all electrical connections are correct and there are no loose wires.
Commission:
8. Turn on the water and check for leaks.
9. Turn on the power.
10. Flush the filter for 3 - 5 minutes.
11. Allow sufficient time for the unit to heat up, before using.
Check List
Page 4 of 16 Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.03
Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Read These Warnings First. . . . . . . . . . . . . . . . . . . . . . . . . . .6
Models covered by these instructions . . . . . . . . . . . . . . . . . .6
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Step A - Installing the tap . . . . . . . . . . . . . . . . . . . . .7
Step B - Installing the undersink unit . . . . . . . . . . . . 8
See special note page 11, ventilation buffers.
Step C - Installing the filter . . . . . . . . . . . . . . . . . . . . 8
Step D - Connecting the tap, . . . . . . . . . . . . . . . . . . . 9
Step E - Connecting the Water Supply . . . . . . . . . . .9
Step F - Testing and commissioning . . . . . . . . . . . . .10
Operating the touch Tap. . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Operating the lever Tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Font Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
End of life disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
NOTE:
All plumbing must comply with AS3500.4.1 & AS3500.4.2
All electrical must comply with AS3300 wiring rules
All refrigeration must comply with AS3350.2.24
Zip HydroTap Installation and Operating Instructions - 89585 - March 2016 v2.03 Page 5 of 16
Read These Warnings First
Safety
This appliance is not intended for use by persons (Including Children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance
Qualifications
If any power cord or plug is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out by
a suitably qualified trades person. The power cord and general power outlet
must be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure
the tap body is located so the tap outlet safely drains into the sink bowl area.
Lifting
Take care when lifting the Zip HydroTap undersink unit. Some units may exceed
safe lifting limits. Do not lift without assistance. The weights of the units are
given in the table under the heading “Installation Requirements”.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC.
Proper air circulation must be provided. The system will operate satisfactorily
only if the recommended air gaps are provided, these are 65mm min rear
clearance and 50mm side clearance. Included in the installation pack are
adhesive backed silicon buffers. If air vents are not installed in the cupboards
housing the HydroTap, the buffers must be placed on the inside edge of the
cupboard door to create a slight gap ensuring a minimum airflow. Failure to do
this may cause the HydroTap to overheat and operate inefficiently.
The power point must be located within
reach of its cable. The appliance must be
positioned so that the plug is accessible.
Note:
Always ensure the hoses are shortened so that any excess is removed
and their route is the most direct line between the tap assembly and the
HydroTap unit.
Do not allow the hoses to sag or droop so water is trapped within the
hoses.
Positioning of the tap assembly must be within the following parameters:
The height between the base of the Hydrotap unit and the base of the Tap
assembly cannot be greater than 900mm.
The height between the top of the unit and the bottom of the tap must be
greater than 400mm.
Zip Hydrotap undersink assembly.
The appliance must be placed on a horizontal
surface in an upright position, as shown above.
This way up