Zip HT2786, HT2785Z4, HT2785Z6, HT4786Z8, HT3786Z7 User Manual

...
0 (0)

ZIP HydroTap® G4

User Guide

Tap Operation...................

 

(Pages 2-9)

LCD Screen & Menu .......

 

(Pages 10-21)

Maintenance....................

 

(Page

21-22)

Menu Icons.......................

 

(Page

23)

Date of Installation............

/

........./

.........

B & BA

Res.

Models

Affix Model Number Label

Here 802258

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00

Page 1 of 24

Tap safety - Boiling Ambient

The safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated.

This function can be activated and deactivated from either the Tap top controls or from the touch screen display (Located on the unit in the cupboard). In order to be able to change the safety lock settings, using the tap top controls, The control panel settings must first be set to YES (allow safety settings change).

To allow the safety setting to be changed using the tap top controls: (Classic, Elite & AIO)

1.

Press [MENU] button for main

 

menu.

 

2.

Press [Setting] button.

3.

Press [Safety] button.

4.

Press button

- YES / NO

 

to allow or disallow the safety

 

setting to be changed on the

 

tap.

 

Note: The Factory setting is set at YES

To activate the safety using the tap top controls

(Classic, Elite & AIO)

After selecting to allow the safety setting from the menu screen. Place a finger on the safety lock, then depress the Classic Blue Ambient lever or touch the Elite Blue/ Ambient Button, while keeping both fingers in position for more than ten seconds.The Classic safety lock indicator light will now be illuminated or the Elite lights will flash, momentarily.

To deactivate the safety using the tap top controls (Classic, Elite & AIO)

First place a finger on the safety lock, then depress the Classic Blue/Ambient lever or touch the Elite Blue/Ambient Button, while keeping both fingers in position for more than ten seconds. The Classic safety lock indicator light will now extinguish or the Elite lights will flash, momentarily.

To control the safety

(From the touch screen):

(see page 20)

For Hot Isolation:

Not for HydroTap Arc/Cube, (see page 20)

Ambient lever

Elite Tap

Page 2 of 24

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00

Tap Safety - Boiling Models

On Boiling Only models the safety lock feature is provided to prevent boiling water flowing if any of the Classic hot levers or Elite buttons are inadvertently operated.

The Safety Lock button on the tap can only be Disabled or Enabled from the LCD touch screen (Located on the unit in the cupboard). When Disabled, no water will be dispensed from the Boiling Hydrotap.

Boiling Models (Classic, Elite & AIO)

To set the safety using the touch screen:

1.Press the [MENU] button for main menu.

2.

Press the [Setting] button.

3.

Press the [Safety] button.

4.

Press button

to Enable /

Disable, the safety lock feature on the tap.

For HydroTap ARC/CUBE:

(Boiling Ambient and Boiling models)

The safety on the tap, can only be Disabled or Enabled from the LCD touch screen (Located on the unit in the cupboard).

Safety Sensor Calibration (lever models)

Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation.

All direct natural sun light must be shaded from the HydroTap, during the calibration. This can be achieved by closing any nearby curtains, blinds, etc. or by shading the tap with a dark cloth.

1.With the unit in Normal operating mode

and with the safety enabled

2.Turn the power OFF

3.Pull both tap levers to the forward position

4.Turn ON the power

Pull both levers forward

Safety sensor

5.The unit will calibrate the safety switch

6.Return the levers to the neutral position.

7.To check the calibration, dispense Boiling water, in normal light conditions with the safety enabled.

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015V2.00

Page 3 of 24

3.Tap functions

Elite Tap:

Boiling Button

Ambient Button

The Elite tap uses touch

sensitive controls, to dispense Safety Lock Boiling, and Ambient water.

When operating the tap, ensure the touch surface is dry as moisture may interfere with the sensor touch control.

The safety lock can be controlled from either the tap or from the touch screen display in the same way as the Classic tap (See page 2)

NOTE:

The safety switch is always active on Boiling Only models

All-In-One Tap:

The top of the All-In-One tap is operated the same as a Classic HydroTap. The two levers are used for

dispensing Boiling and Ambient water. The safety button operating in the same way as on the HydroTap.

The Mixer tap lever is operated as a classic ‘Flick Mixer’. The hot side is marked with a red mark and the cold side with a blue mark, for dispensing cold to warm water.

Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off.

When the handle is moved

towards the blue mark, the temperature is decreased and when moved towards the red mark, the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.

For convenience, the spout may be swivelled, left or right through 120°.

Page 4 of 24

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00

Rotary control
Select Button
Safety Lock

3. Tap functions

HydroTap Arc/Cube:

On powerup, wait 30 secs. for the unit to calibrate itself. Tapping the select button will allow the choice of Boiling (RED) with safety or Ambient (BLUE) water modes. The Arc/Cube control may be

rotated in a forward or reverse direction to dispense Boiling or Ambient water.

The rotary control is spring loaded in the anticlockwise direction and when released, will return to the OFF position. When rotated clockwise the

tap operates in a “Pot fill” mode. Water will flow from between 5 and 15 seconds

(This is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be

manually returned to the “Off” position.

After activating the Boiling mode, all the lights will flash for 2 seconds, during which time you may dispense water. When the rotary control is returned to the Off position the light will continue to flash for an additional 3 seconds, allowing you to dispense more water.

When unattended, the control light will automatically default to the Ambient(- BLUE) mode after 30 seconds.

MixerTap:

Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Raise the handle all the way up to turn the tap off.

When the handle is moved towards the BLUE mark, the temperature is decreased and when moved towards the RED mark, the temperature is increased. The final temperature will depend

on the temperature of the incoming cold water.

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015V2.00

Page 5 of 24

3.Tap operation

To dispense boiling water: HydroTap Classic:

(With the safety OFF) Classic Tap

Depressing the Red lever allows the dispensing of boiling water.

Pulling forward the Red lever allows the tap to operate in a “no-touch” mode.

Water will flow from between 5 and 15 seconds (This is user adjustable).

To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.

Elite Tap:

Touching the boiling button allows the dispensing of boiling water.

HydroTap Arc/Cube:

If not showing RED, tap the select button until the indicator light turns RED.

Rotating the control, when the indicator light is RED, allows the dispensing of boiling water.

To dispense Boiling

water: (With the safety ON)

HydroTap Classic:

Depress the Red lever, while simultaneously covering the safety lock button with a second finger. These two actions need to occur within 2 seconds for the successful dispensing of boiling water.

Elite Tap:

Place a finger on the safety lock, then touch the boiling button, while keeping both fingers in position.

HydroTap Arc/Cube:

First tap the select button until the indicator light turns RED. Then tap the safety button twice until the RED light flashes (This will flash for aprox 1-3 seconds if no water is being dispensed). Boiling water may be dispensed by rotating the control while the RED light is flashing.

Elite Tap

Indicator

light

Safety Lock

Arc/Cube Tap

Page 6 of 24

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00

3. Tap operation

To dispense Ambient water:

Classic Tap

 

HydroTap Classic:

 

Depressing the Blue lever allows the

 

dispensing of Ambient water.

 

Pulling forward the Blue lever allows the

 

tap to operate in a “no-touch” mode.

 

Water will flow from between 5 and 15

 

seconds (This is user adjustable).

 

To reset, return the lever to the “Off”

 

position and repeat the step. The lever

 

has to be manually returned to the “Off”

 

position.

 

Ambient button

Elite Tap:

Touching the Ambient button allows the dispensing of Ambient water.

HydroTap Arc/Cube:

If not showing Blue, tap the select button until the indicator light turns Blue.

Rotating the control, when the indicator light is Blue, allows the dispensing of Ambient water.

Indicator

light

Select button

Arc/Cube Tap

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015V2.00

Page 7 of 24

Zip HT2786, HT2785Z4, HT2785Z6, HT4786Z8, HT3786Z7 User Manual

Filter lights

 

Red Light

Filter Light

Filter light: Classic & Elite

 

 

Filter Change Light Off:

 

 

This indicates the filter is operating within its

 

 

normal specified lifespan.

 

 

Filter Change light flashing slowly:

 

 

The light will flash slowly when the filter is due

 

 

for replacement and the LCD will show “Filter

 

 

Change”. Refer to “Replacing the filter” in

 

 

section ‘C’ of this document.

Elite Tap

Indicator

light

HydroTap Arc/Cube Flashing filter lights:

All three tap lights (Safety; Select and Indicator light) will flash every

10 seconds, indicating a Filter change is required.

Turn filter light OFF: (All models)

Refer to “Filter Reset” in section ‘C’ of this document.

Select light

Safety Light

Classic Tap

Page 8 of 24

802258 - B, BA, BHA, BAHA, - HydroTap User Guide - July 2015 - V2.00

Loading...