AZ732
MINIATURE
POWER RELAY
FEATURES
Dielectric strength 4000 Vrms coil to contact
Isolation spacing greater than 8mm
Double pole – Forms A, B and C available
10A switching
SLIMPACK
TM
version saves board space
Epoxy sealed version for automatic wave soldering and
cleaning
Approvals/Standards include : UL, CSA, VDE, IEC, SEMKO
and CEE
UL File E44211 ; CSA File LR85091 ;
VDE 4120-4940-4002/A1
Lo
istic Desi
n
UK
Limited
Unit 3 Eagle Centre W ay, Sedgwick Road Tel +44 (0)1582 599 600
Luton LU4 9US, United Kingdom Fax +44 (0)1582 599 700
CONTACTS
Arrangement DPDT (2 Form C)
Ratings Resistive load :
Max switched power : 300W, 2770VA
Max switched current : 10A, 51A for 2m s
Max switched voltage : 150*VDC / 400VAC
UL Rating : 10A at 30VDC or 277VAC
0.125HP 120VAC motor load
*Note : If switching voltage is greater than 30VDC, special
precautions must be taken. Please contact the factory.
Material Silver cadmium oxide
Resistance <30 miiliohms initially
(at rated current, voltage drop method)
Power
At Pickup Voltage Standard coil 337mW
(typical) Sensiti ve c oi l 250mW
Max Continuous 1.9W 20°C am bi ent
Dissipation 1.4W 40° C ambient
Temperature Rise Standard 40°C at nominal coi l vol tage
Sensitive 32°C at nominal coil voltage
Max Temperature 110°C
Life Expectancy Minimum operations
Mechanical 30 million
Electrical 1x10
5
at10A 30VDC
1x10
5
at 10A 115VAC
Operate Time (typical) 7ms at nominal c oi l voltage
Release Time (typical) 2ms at nomi nal coil voltage
(with no coil suppression)
Dielectric Strength 4000 Vrms coil to c ont acts
(at sea level for 1 min) 2500 Vrms contact to cont act
1000 Vrms between open contacts
Insulation Resistance 10,000 megohms m i n at 20°C. 500VDC,
50% RH
Dropout Greater than 10% of nominal c oi l vol t age
Ambient Temperature At nominal coil voltage
Operating Standard -55°C to 70°C
Sensitive -55°C to 80°C
Storage Both -55°C to 110°C
Vibration 0.062” DA at 10 – 55 Hz
Shock 20g
Enclosure PBT polyester
Terminals Tinned copper alloy, PC
Weight 20 grammes
GENERAL DATA
NOTES
1. All values at 20°C
2. Relay may pull in with less than ‘Must Operate’ value
3. PCB layout viewed towards terminals
4. Unsealed relays should not be dip cleaned
5. Specifications subject to change without notic e
COIL
www.zettlerrelay.com
sales@zettlerrelay.com
LDZR201000