Zephyr DVSE36ASSX, DLAM90ASSX, DLAE42ASSX, DVSE30ASSX Installation instructions

0 (0)

www.zephyronline.com

LAYERS WALL

DLA-E42ASSX

DLA-M90ASSX

VISTA WALL

DVS-E30ASSX

DVS-E36ASSX

RANGE HOOD - Installation instructions

ENGLISH..........................

3

FRANÇAIS.......................

28

Table of Contents

SAFETY INSTRUCTIONS..................................................................................................

pag. 4

LIST OF MATERIALS...........................................................................................................

pag. 8

DUCTING CALCULATION SHEETS............................................................................

pag. 10

HOOD SPECIFICATION..................................................................................................

pag. 11

INSTALLATION

 

- INTERNAL BLOWER.....................................................................................

pag. 13

- EXTERNAL & IN-LINE BLOWER PREPARATION...............................

pag. 15

- DUCTING OPTIONS.....................................................................................

pag. 17

- MOUNTING THE RANGE HOOD.............................................................

pag. 18

- POWER SUPPLY CONNECTION..............................................................

pag. 19

- MOUNTING THE DUCT COVER..............................................................

pag. 20

TOUCH CONTROL............................................................................................................

pag. 21

OPTIONAL REMOTE CONTROL..................................................................................

pag. 22

MAINTENANCE ................................................................................................................

pag. 23

WIRING DIAGRAMS...............................................................................................................

pag. 24

LIST OF PARTS AND ACCESSORIES ........................................................................

pag. 26

WARRANTY .......................................................................................................................

pag. 27

- 3 -

Safety instructions 1/4

IMPORTANT SAFETY INSTRUCTIONS

FOR RESIDENTIAL USE ONLY

READ AND SAVE THESE INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.

Take care when using cleaning agents or detergents.

Suitable for use in household cooking area.

WARNING - To reduce the risk of fire or electric shock, do not use this fan with any Solid-State Speed Control Device.

CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

CAUTION - For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

CAUTION - Please read specification label on product for further information and requirements.

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.Never leave surface units unattended at high settings. Boilovers cause smok

-4 -

Safety instructions 2/4

ing and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.Always turn hood ON when cooking at high heat or when flambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ).

C.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D.Use proper pan size. Always use cookware appropriate for the size of the surface element.

E.Keep fan, filters and grease laden surface clean.

F.Use high range setting on range only when necessary. Heat oil slowly on low to medium setting.

G.Don’ t leave range unattended when cooking.

H.Always use cookware and utensils appropriate for the type and amount off food being prepared.

WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

A.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

B.NEVER PICK UP A FLAMING PAN – You may be burned.

C.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

D.Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.The fire is small and contained in the area where it started.

3.The fire department is being called.

4.You can fight the fire with your back to an exit.

aBased on “kitchen firesafety tips” published by NFPA

Proper maintenance of the Range Hood will assure proper performance of the unit.

INSTALLATION INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

-5 -

Safety instructions 3/4

B.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D.Ducted fans must always be vented to the outdoors.

E.This unit must be grounded.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS.

A.Do not check filters with hood working.

B.Do not touch the lamps after a prolonged use of the appliance.

C.No food must be cooked flambè underneath the hood.

D.The use of an unprotected flame is dangerous for the filters and could cause fires.

E.Watch constantly the fried food in order to avoid the cooking oil flares up.

F.Before performing any mainteinance operation, disconnect the hood from the electrical service.

The manufacturers will not to accept any responsibility for eventual damages, because of failure to observe the above instructions.

Electrical Requirements

Important:

-Observe all governing codes and ordinances.

-It is the customer’s responsibility to be aware of these below:

-To contact a qualified electrical installer.

-To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1- 94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

-If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

-Do not ground to a gas pipe.

-Check with a qualified electrician if you are not sure the range hood is properly grounded.

-6 -

Safety instructions 4/4

-Do not have a fuse in the neutral or ground circuit.

-This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.

-A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.

* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269

** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

Federal Communication Commission Interface Statement

-This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

-This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

WARNING Prop. 65 Warning for California Residents: This product may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

- 7 -

List of Materials

Models: DLA-E42ASSX / DLA-M90ASSX

Duct Covers

Assembly

Duct Cover Bracket

Box marked

 

 

'120 VAC input'

 

 

 

Remote Blower

 

 

 

 

 

 

Electrical

 

Box

System Box

 

 

 

 

 

 

Control

Filters

Led Light

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Blower

 

 

 

 

 

 

Wiring Harness

 

 

 

 

 

 

Remote Blower

 

 

 

 

 

 

 

 

Remote Blower

 

 

Wiring Extension

Hardware

Collar with Damper

 

 

 

 

 

 

- 8 -

List of Materials

Models: DVS-E30ASSX / DVS-E36ASSX

Duct Covers

Assembly

Box marked '120 VAC input'

Electrical

System Box

Control

Remote Blower

Wiring Harness

Remote Blower Collar with Damper

Duct Cover Bracket

Remote Blower

Box

Led Light

Filters

Panel

Remote Blower

Hardware

Wiring Extension

- 9 -

Ducting Calculation Sheet

Duct pieces

Equivalent number

Total

 

length x used

 

=

3-1/ 4” x 10”

1 Ft.

x (

)

=

Ft.

Rect.,

 

 

 

 

 

straight

 

 

 

 

 

6”, 7”, 8”, 10”

1 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

straight

 

 

 

 

 

3-1/ 4” x 10”

15 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

9 Ft.

x (

)

=

Ft.

Rect.450

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

24 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

flat elbow

 

 

 

 

 

7” to 6” or

25 Ft.

x (

)

=

Ft.

8” to 7” Round

 

 

 

 

 

tapered

 

 

 

 

 

reducer

 

 

 

 

 

6”, 7“, 8”

15 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

in-line

 

 

 

 

 

damper

 

 

 

 

 

6”, 7”, 8”, 10”

15 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

900 elbow

 

 

 

 

 

6”, 7”, 8”, 10”

9 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

450 elbow

 

 

 

 

 

 

Subtotal column 1 =

Ft.

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 150 equivalent feet.

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

3-1/ 4” x 10”

5 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

3-1/ 4” x 10”

20 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

6” round to

1 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

6” round to

16 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

7” round to

8 Ft.

x (

)

=

Ft.

3 1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

7” round to

23 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

3-1/ 4” x 10”

30 Ft.

x (

)

=

Ft.

Rect.

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

6”, 7”, 8”, 10”

30 Ft.

x (

)

=

Ft.

Round, wall

 

 

 

 

 

cap with

 

 

 

 

 

damper

 

 

 

 

 

6”, 7”, 8”, 10”

30 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

roof cap

 

 

 

 

 

Subtotal column 2 =

Ft.

Subtotal column 1 =

 

Ft.

Total ductwork

=

 

Ft.

- 10 -

Hood Specifications

Models: DLA-E42ASSX / DLA-M90ASSX

Front of Hood

Side of Hood

11-1/8”

STANDARD

min. ducted - 27” min. recirc. - 31” max. - 44-1/2”

Z1C-00VS

min. ducted - 43-1/2” min. recirc. - 47-1/2” max. - 80”

27-9/16”

35-3/8”, 41-15/16”

 

 

9-15/16”

 

 

<![if ! IE]>

<![endif]>18-1/8”

<![if ! IE]>

<![endif]>1/16”

 

 

 

 

<![if ! IE]>

<![endif]>14-

 

 

 

 

<![if ! IE]>

<![endif]>9/16”

16-1/2”

<![if ! IE]>

<![endif]>5/8”

<![if ! IE]>

<![endif]>1-3/4”

 

 

 

<![if ! IE]>

<![endif]>3-

22”

 

 

 

 

 

 

Top of Hood

<![if ! IE]>

<![endif]>4-5/16” (Ø 8") Remote Blower

<![if ! IE]>

<![endif]>3-1/2” (Ø 6'') Internal Blower

<![if ! IE]>

<![endif]>16-1/2”

Back of Hood

8”

<![if ! IE]>

<![endif]>3/4”

9-3/16” 15/16”-16

- 11 -

Hood Specifications

Models: DVS-E30ASSX / DVS-E36ASSX

Front of Hood

11-1/4”

STANDARD

min. ducted - 25-1/2” min. recirc. - 29-1/2” max. - 38-1/2”

Z1C-00VS

min. ducted - 42” min. recirc. - 46” max. - 78-1/2”

30” or 36”

Side of Hood

10-1/16”

<![if ! IE]>

<![endif]>17-5/8”

<![if ! IE]>

<![endif]>13-9/16”

 

18-7/8”

 

<![if ! IE]>

<![endif]>2-1/8”

 

 

 

Back of Hood

 

Top of Hood

 

8”

 

 

 

<![if ! IE]>

<![endif]>3/4”

<![if ! IE]>

<![endif]>18-7/8”

<![if ! IE]>

<![endif]>1/4”-4( 8") RemoteBlower

<![if ! IE]>

<![endif]>7/16”-3( 6" InternalBlower

9-1/8”

<![if ! IE]>

<![endif]>7/16”

 

 

<![if ! IE]>

<![endif]>(

 

 

 

 

<![if ! IE]>

<![endif]>16-

- 12 -

Installation - Internal Blower

The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with internal blower models CBI-290A or CBI-600A.

For external and in-line blower preparation please turn to page 15.

1.Remove the 6” round metal knockout plate from the blower plate by using a flat head screwdriver. See.Fig.1

2.Remove the (6) screws securing the blower plate to the blower housing

and remove blower plate. See. Fig.2

3. Install internal blower into blower plate and secure using (4) screws included with the blower. See Fig.3

4. Secure capacitor box connected to the provided cable to the blower plate using (2) screws included with the blower. See.Fig.4

5. Secure Green/Yellow ground wire connected to the cable to the provided capacitor to blower plate.Fig.5

6.Attach the 6 pin male molex connector from blower wire to the 6 pin fe-

male molex connector located inside the blower housing. See Fig.6

- 13 -

7.Install blower and blower plate into blower housing by following the reverse instructions from step 2

then use the screws provided to complete installation. (Tot. 14). See Fig.7

8.Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.8

WARNING! Place electrical wiring inside the motor housing.

The hood is now ready to be installed on the wall.

- 14 -

Installation - External & In-Line Blower Preparation

The following instructions are for preparing the hood for use with an external or in-line blowers models CBE-1000 or PBN-1000A.

CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A.

For internal blower instructions please turn to page 13.

1. Remove the (6) screws securing the blower plate to the blower housing and remove blower plate. See.Fig.1

2. Detach rectangular metal plate from blower plate. See Fig. 2A Flip blower plate 90 degrees and attach rectangular plate to blower plate side with round knock-out.See Fig.2B

3. Re-install blower plate into blower housing by following reverse instructions from step 1 then use the screws provided to complete installation. (Tot.14)

4. Remove top knock-out plate and remote blower knock-out plate by using a flat head screwdriver. See Fig. 3 and Fig. 4

5. Secure 8” round blower collar to top of blower

- 15 -

Zephyr DVSE36ASSX, DLAM90ASSX, DLAE42ASSX, DVSE30ASSX Installation instructions

housing using (4) screws. See Fig. 5

6. Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box included in the hardware packet to top of blower housing using (2) screws. See Fig. 6B

7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7

Note: Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999.

8.Secure cover to junction box using (2) screws.

Note1: A cable lock (not included) may be required by local codes. Please review local codes for more information.

9. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower housing. See Fig. 8

Note2: Check local codes to determine minimum wire gauge.

See manual included with external and inline blower for instructions on installing the blower.

- 16 -

Installation - Ducting Options

WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.

All exhaust must be ducted to the outside, unless using the recirculating option.

Use single wall rigid Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.

Some Ducting Options

- 17 -

Loading...
+ 39 hidden pages