Zephyr ALAE42BWX, ALAM90BWX, ADLM90BSX, ADLE42BSX, ADUM90BSX User Manual

...
0 (0)

Use, Care, and Installation Guide

www.zephyronline.com

External Blower

CBE-1000

Model number: CBE-1000

Serial number:

Date of Purchase:

Sales Dealer:

JUL13.0201 © Zephyr Ventilation

Important s afety Notice

www.zephyronline.com

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO RE DUC E THE R IS K O F FIR E O R E LE C TR IC SHOCK, DO NOT US E THIS FAN W ITH ANY S O LID-S TATE SP E E D C O NTRO L DEV IC E.

WARNING

TO RE DUC E THE R IS K O F FIR E, E LE C TR IC SH O C K, O R INJU RY TO PE R SON S, O B S E RVE THE FO LLOW ING:

a.Use this unit only in the manner intended by the manufacturer, If you have questions, contact the manufacturer.

b.Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominentwarning device, such as tag, to the service panel.

CAUTION

For General VentilatingUse Only. Do not Use to Exhaust Hazardous or Explosive Materials and Vapors.

WARNING

TO RE DUC E THE R IS K O F A RA NG E TO P GR EAS E FIR E:

a. Never leave surface units unattendedat high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or mediumsettings.

b.Always turn hood ON when cooking at high heat or when cooking ambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe)

c.Clean ventilatingfans frequently. Grease should not be allowed to accumulate on fan or lter.

d.Use proper pan size. Always use cookware appropriatefor the size of the surface element.

WARNING

TO RE DUC E THE R IS K O F INJURY TO PER SON S IN THE EV E NT O F A RA NG E TO P G R EAS E FIR E, O B S E RVE THE FO LLOW ING :

a. SMOTHER FLA MES with a closetting lid, cookie sheet, or metal tray, then turn o the burner. B E CARE FUL TO PR EV E NT BUR NS. If the ames do not go out immediately, EVACUATE AND CALL THE FIR E DE PARTMENT.

b. NEV E R PIC K UP A FLAMI NG PAN - You may be burned.

c. DO NOT US E WATE R, includingwet dishcloths or towels - a violentsteam explosion will result.

d.Use an extinguisher ONLY if:

1.You know you have a class AB C extinguisher, and you already know how to operate it.

2.The re is small and contained in the area where it started.

3.The re departmentis being called.

4.You can ght the re with your back to an exit.

5.Based on “Kitchen Fire Sa fety Tips” published by NFPA.

WARNING

TO R E DUC E THE R IS K O F FIR E, E LEC TR IC SHOCK O R INJURY TO PER SON S, O B S E RVE THE FO LLOW ING :

a.Installation Work and Electrical Wiring Must be Done by Quali ed Person (s) In Accordance with all Applicable Codes and Standards, IncludingFire-Rated Construction.

b.Su cient air is needed for proper combustionand exhausting of gases throughthe ue (chimney) of fuel burningequipmentto prevent back drafting. Follow the heating equipmentmanufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air ConditioningEngineers (ASHRAE) and the local code authorities.

c.When cutting or drillinginto wall or ceiling, do not damage electrical wiring and other hidden utilities.

d.Ducted fans must always vent to the outdoors.

WARNING

TO RE DUC E THE R IS K O F FIR E, US E O NLY METAL DUC TW O R K.

CAUTION

To reduce risk of re and to properlyexhaust air, be sure to duct air outside - Do not vent exhaust air into spaces withinwalls or ceilings or into attics, crawl spaces or garages.

CBE-1000 external blower is to be used only with compatible Zephyr hoods. Please refer to hood manual for external blower compatibility.

1

Zephyr ALAE42BWX, ALAM90BWX, ADLM90BSX, ADLE42BSX, ADUM90BSX User Manual

NOTE:

The following instructions explain the mounting procedures for the CBE-1000 external blower. Refer to your hood’s installation manual for instructions on preparing the hood for use with the external blower.

The mounting location of your external blower will impact the noise levels. Plan your installation accordingly.

 

Fig-5

 

 

24"

 

 

 

 

 

 

3"

 

 

8"

4"

 

 

 

 

5 5/8"

10 1/4"

 

 

 

 

30"

 

7 1/2"

 

7 1/8"

 

 

 

2"

 

 

 

8"

1 5/8"

 

 

 

 

 

2 3/4"

Fig-1

TYPICAL INSTALLATION

ROOF MOUNT

OUTSIDE WALL MOUNT

10" Elbow

 

 

10" Duct

Roof

10" Elbow

 

 

Hood

Hood

 

 

 

 

 

Outside Wall

 

 

 

 

 

 

 

 

 

 

 

 

Recommended for use only over conventional domestic gas and electric ranges.

Installation - External Blower Specifications

2