York YUHC 07-18, YUHC 18-60 User Manual

0 (0)
York YUHC 07-18, YUHC 18-60 User Manual

Installation & Owner’s Manual

MINISPLIT AIR BLOWER

MODELS

YUHC 18-60 YUKC 07-18

 

EN 035M00065-000

J368-EN.indd 1

2/1/07 9:40:52 AM

Please read this installation manual carefully before starting the installation. It will tell you necessary information.

Quality POLICY

We will continuously strive to satisfy our customers with consistent reliability in product, service and support through superior quality, service culture and distinctive technology.

CONTENTS

 

Safety Precautions...................................................

3

Part Names................................................................

4

Technical Specifications..........................................

5

Outdoor Unit Dimensions........................................

9

Preparation Before Installation.............................

10

Installation...............................................................

10

Condensate Drainage ............................................

14

Refrigerant Piping Connects.................................

15

Fan Speeds .............................................................

16

Wiring Diagrams.....................................................

17

Defrosting Operation..............................................

20

Service and Maintenance ......................................

20

Operation Tips ........................................................

21

Trouble Shooting Guide.........................................

22

Declaration of Conformity .....................................

23

Refrigerant

DC INVERTER R-410A

Model

18-24

36-48

60

Set

YUHCxxDUBAAR-K

YUHCxxDUBACR-K

YUHCxxDSBACR-K

Outdoor

YUJCxxDU-BAR

YUJCxxDU-BCR

YUJCxxDS-BCR

Indoor

YUKCxxDU-BAR-K

YUKCxxDU-BCR-K

YUKCxxDS-BCR-K

 

Multi Inverter R-410A

 

50Hz/1Ph

Outdoor

RRJCxxAA-AAA

 

 

Indoor

YUKCxxAA-AAR

Standard

Refrigerant

 

R-410A

Model

18-24

 

30-60

Set

YUHCxxFUAAAR

 

YUHCxxFUAACR

Outdoor

YUJCxxFU-AAR

 

YUJCxxFU-ACR

Indoor

YUKCxxFU-AAR

 

YUKCxxFU-ACR

With Low Ambient Kit

Refrigerant

 

R-410A

Model

18-24

 

30-60

Set

YUHCxxFUBAAR

 

YUHCxxFUBACR

Outdoor

YUJCxxFU-AAR

 

YUJCxxFU-ACR

 

 

 

 

Indoor

YUKCxxFU-AAR

 

YUKCxxFU-ACR

J368-EN.indd 2

 

 

2/1/07 9:40:52 AM

 

 

 

 

 

 

REQUIRED TOOLS

 

 

EXTENDED PARTS

1.

Screw driver

9.

Manifold gauge

1.

Refrigerant Pipe : See Technical Specification

2.

Hexagonal wrench

10.

Gas leak detector

2.

Pipe insulation material (Polyethylene foam 9 mm thick)

3.

Torque wrench

11.

Vacuum pump

3.

Vinyl tape

4.

Spanner

12.

Pipe clamp

4.

Putty

5.

Reamer

13.

Pipe cutter

 

 

6.

Hole core drill

14.

Flare tool set

 

 

7.

Tape measure

15.

Electrical circuit tester

 

 

8.

Thermometer

 

 

 

 

SAFETY PRECAUTIONS

Please read this installation manual carefully before starting installation of the unit.

This air conditioning system contains refrigerant under pressure, rotating parts and electrical connection which may be dangerous and can cause injury. Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel.

After unpacking, please check the unit carefully for possible damage.

Before undertaking any work on the unit, make sure that the power supply has been disconnected.

WARNING & CAUTIONS

Danger

No

CAUTION

Do not attempt to install this unit by yourself. This unit requires installation by qualified persons.

DANGER

Do not attempt to service the unit yourself. This unit has no user serviceable components. Opening or removing the cover will expose you to dangerous voltage. Turning off the power supply will not prevent potential electric shock.

DANGER

Never put hands or objects into the Air Outlet of indoor or outdoor units. These units are installed with a fan running at high speed. To touch the moving fan will cause serious injury.

DANGER

To avoid the risk of serious electrical shock, never sprinkle or spill water or liquids on unit.

WARNING

Ventilate the room regularly while the air conditioner is in use, especially if there is also a gas appliance in use in this room. Failure to follow these directions may result in a loss of oxygen in the room.

WARNING

Thinner

To prevent electric shock, turn off the power or disconnect the power supply plug before beginning any cleaning or other routine maintenance. Follow the directions for cleaning in this manual.

WARNING

Do not use liquid cleaners or aerosol cleaners, use a soft and dry cloth for cleaning the unit. To avoid electric shock, never attempt to clean the unit by sprinkling water.

WARNING

Do not use caustic household drain cleaners in the unit. Drain cleaners can quickly destroy the unit components (drain pan and heat exchanger coil, etc.)

WARNING

For proper performance, operate the unit in temperature and humidity ranges indicated in this manual. If the unit is operated beyond these conditions, it may cause abnormal functions of the unit or dew dripping from the unit.

ENGLISH 3

J368-EN.indd 3

 

 

2/1/07 9:40:54 AM

 

 

 

 

 

 

PART NAMES

INDOOR UNIT

I J

A

E K L M N

Display Panel

B

F

D

G H

OUTDOOR UNIT

E

C

■ INDOOR & OUTDOOR UNIT

■ DISPLAY PANEL

A. Indoor unit

I. Infrared signal receiver

B. Outdoor unit

J. Emergency button

C. Remote controller

K. Running indicator

D. Air-in

L. Timer indicator

E. Air-out

M. Frost indicator (cooling and heating type)

F. Air inlet

or fan indicator (cooling only type)

G. Connecting pipe

N. Pump indicator

H. Drain hose

 

 

NOTE

 

All the pictures in this manual are for explanation

 

purpose only. They may be sightly different from the

 

air conditioner you purchased. The actual shape shall

 

prevail.

4ENGLISH

J368-EN.indd 4

 

 

2/1/07 9:40:55 AM

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS

Technical Specifications : Duct Type YUHC “R-410A” -50Hz

 

 

 

 

Indoor

 

 

YUKC

 

 

Models

 

 

Unit

18

24

30

36

48

60

 

 

Outdoor

 

 

YUJC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

18

24

30

36

48

60

Power Supply

 

V/Ph/Hz

220-240/1/50

 

380/3/50

 

 

Ph

1

1

3

3

3

3

 

 

 

 

Power Consumption

 

W

1,900/1,900

2,560/2,500

3,250/3,250

3,700/3,350

4,700/4,900

6,000/6,000

Running Current

 

A

8.8/8.8

12.2/11

5.5/5.5

6.5/5.8

8.2/8.6

9.8/9.8

Refrigerant Type

 

 

 

 

R-410A

 

 

Refrigerant Charge

 

gr

2,050

2,600

3,100

3,100

4,000

4,200

Noise level

Indoor

dB(A)

38

38

44

44

46

47

Outdoor

48

55

57

57

58

58

 

 

 

 

 

Power Supply

 

V/Ph/Hz

 

 

220-240/1/50

 

 

 

 

Ph

1

1

1

1

1

1

 

 

 

 

 

Fan

Air flow

 

m3/h

1,160

1,460

2,070

2,070

2,400

2,800

Unit

Input Power

 

W

117

170

118

118

118

227

 

 

 

Indoor

 

Running Current

A

0.53

0.77

0.54

0.54

0.54

1.03

 

 

Height

mm

300

300

300

300

300

320

 

 

 

 

Dimension

Width

mm

1,000

1,000

1,350

1,350

1,350

1,350

 

 

 

Depth

mm

800

800

800

800

800

800

 

Weight

 

kg

36

38

48

48

50

70

 

System Operation Control

 

 

 

Wireless Control with LCD Display

 

 

 

Power Supply

 

V/Ph/Hz

220-240/1/50

 

380/3/50

 

 

 

Ph

1

1

3

3

3

3

 

 

 

 

 

Compressor

Qty

 

1

1

1

1

1

1

Unit

Compressor Type

Rotary

 

Scroll

 

 

 

 

 

 

 

Height

mm

695

860

960

960

1,245

1,245

Outdoor

 

 

 

 

 

 

 

 

 

 

Dimension

Width

mm

845

895

990

990

940

940

 

 

 

 

Depth

mm

335

330

360

360

360

360

 

Weight

 

kg

55

79

101

101

110

110

 

Piping

Type

 

 

 

 

Flare + Nuts

 

 

 

Pipe Size

Suction

inch

1/2

5/8

3/4

3/4

3/4

3/4

 

 

 

 

 

 

Liquid

inch

1/4

3/8

1/2

1/2

1/2

1/2

ENGLISH 5

J368-EN.indd 5

 

 

2/1/07 9:40:56 AM

 

 

 

 

 

 

Technical Specification: Ducted Dc Inverter “YUHC” R-410A, 50Hz.

Model

 

Set

YUHC18DUBAAR-K

YUHC24DUBAAR-K

YUHC36DUBACR-K

 

YUHC48DUBACR-K

YUHC60DSBACR-K

 

Indoor

YUKC18DU-BAR-K

YUKC24DU-BAR-K

YUKC36DU-BCR-K

 

YUKC48DU-BCR-K

YUKC60DS-BCR-K

 

 

Outdoor

YUJC18DU-BAR

YUJC24DU-BAR

YUJC36DU-BCR

 

YUJC48DU-BCR

YUJC60DS-BCR

Power supply

 

V-Ph-Hz

220~240-1-50

220~240-1-50

380V~3~50Hz

 

380V~3~50Hz

380V~3~50Hz

Cooling

Capacity

Btu/h

18,000

24,000

36,000

 

48,000

60,000

Input

W

1,570

2,130

3,260

 

4,250

4,840

 

Rated current

A

7

10

9

 

11

11

Heating

Capacity

Btu/h

21,000

28,000

40,000

 

53,000

62,000

Input

W

1,630

2,190

3,120

 

4,140

4,800

 

Rated current

A

7

10

8

 

11

11

Max. input consumption

W

2,600

2,800

3,560

 

4,750

5,950

Max. current

 

A

10

11

10

 

13

16

Starting current

 

A

1

1

1

 

1

1

 

Type

 

DC Inverter Rotary

 

 

DC Inverter Scroll

 

 

Input

W

1,650

1,650

3,665

 

3,665

3,665

 

Rated current (RLA)

A

8

8

8

 

8

8

Compressor

Locked rotor

A

28

28

28

 

28

28

Amp (LRA)

 

 

 

 

 

 

 

 

 

 

Protector

 

 

 

Thermal

 

 

 

Capacitor

µF

50

50

50

 

50

50

 

Refrigerant oil

ml

480

480

500

 

500

500

 

Type

 

 

 

AC Motor

 

 

Indoor fan motor

Input

W

117

170

118

 

324

160

Capacitor

µF

3

7

3

 

10

10

 

 

 

Speed (Hi/Me/Lo)

r/min

900/800/690

1,100/1,020/900

820/695/620

 

870/770/700

870/770/700

 

Number of rows

 

3

3

3

 

3

3

 

Fin spacing

mm

2

2

2

 

2

2

Indoor coil

Fin type

 

 

 

Hydrophilic aluminium

 

 

Tube outside dia.

mm

 

 

Ø9.52

 

 

 

 

Material Type

 

 

 

Innergroove tube

 

 

 

Coil length x

mm

800×254×66

800×254×66

1,150×254×66

 

1,150×254×66

1,150×305×66

 

height x width

 

 

 

 

 

 

 

 

 

Indoor air flow (Hi/Me/Lo)

m3/h

1,020/870/700

1,275/1,170/1,030

2,070/1,950/1,860

 

2,400/2,300/2,200

2,800/2,700/2,600

Indoor external static pressure (Hi)

Pa

40

40

70

 

70

96

Indoor noise level (Hi/Me/Lo)

dB(A)

50/-/-

53/-/-

49/47/44

 

51/47/44

52/48/46

 

Dimension

mm

1,095×805×290

1,095×805×290

1,350×298×800

 

1,350×320×800

1,350×320×800

 

(WxHxD)

 

Indoor unit

 

 

 

 

 

 

 

Packing

mm

1,205×940×370

1,205×940×370

1,555×940×370

 

1,555×440×940

1,555×440×940

 

(WxHxD)

 

 

 

 

 

 

 

 

 

 

Net/Gross weight

kg

38/45

38/45

48/57

 

70/80

70/80

Outdoor fan

Input

W

129

150

307

 

150×2

150×2

Capacitor

µF

3

3

10

 

3.5×2

3.5×2

motor

 

Speed

r/min

770

800

740

 

800

800

 

 

 

Number of rows

 

2

2

1

 

1

1

 

Fin spacing

mm

2

2

2

 

2

2

Outdoor coil

Fin type

 

 

 

Hydrophilic aluminium

 

 

Tube outside dia.

mm

 

 

Ø9.52

 

 

 

 

Tube Material

 

 

 

Innergroove tube

 

 

 

Coil length x

mm

630×660×44

620×813×44

955×915×22

 

715×610×22

1150×305×66

 

height x width

 

 

 

 

 

 

 

 

 

Outdoor air flow

 

m3/h

2,400

3,000

5,000

 

6,000

6,000

Outdoor noise level

 

dB(A)

56

55

57

 

58

58

 

Dimension

mm

840×677×310

894×860×302

990×960×340

 

940×1,245×340

940×1245×340

 

(WxHxD)

 

Outdoor unit

 

 

 

 

 

 

 

Packing

mm

965×770×395

1,043×915×395

1,120×1015×435

 

1,058×1300×435

1,058×1,300×435

 

(WxHxD)

 

 

 

 

 

 

 

 

 

 

Net/Gross weight

kg

62.5/66.5

72/76.5

106/111

 

117/126

112/127

Refrigerant R-410A

 

g

1,650

2,200

2,600

 

3,550

4,200

Throttle type

 

 

 

 

EXV&Capillary

 

 

Refrigerant piping

Liquid side/

mm

6.35/12.7

9.53/16

9.53/16

 

9.53/16

9.53/16

Gas side

 

6ENGLISH

J368-EN.indd 6

 

 

2/1/07 9:40:56 AM

 

 

 

 

 

 

TECHNICAL SPECIFICATION: EVEREST MULTI INVERTER “YUKC-RRJC” 50Hz

Indoor Unit Duct Type YUKC 07-18

Model

 

 

YUKC 07AA-AAR

YUKC 09AA-AAR

YUKC 12AA-AAR

YUKC 18AA-AAR

Power supply

 

Ph-V-Hz

1Ph, 220-240V~, 50Hz

1Ph, 220-240V~, 50Hz

1Ph, 220-240V~, 50Hz

1Ph, 220-240V~, 50Hz

 

Cooling Capacity

BTU/h

7,000

9,000

12,000

18,000

Capacity

Heating Capacity

BTU/h

8,000

11,000

14,000

21,000

 

Power input

w

40

40

40

65

Indoor fan

Input

W

38

38

38

63

Capacitor

µF

1.0µF/450V

1.0µF/450V

1.0µF/450V

2.5µF/450V

motor

Speed (Hi/Mi/Lo)

r/min

735/650/560

735/650/560

735/650/560

930/830/660

 

 

Number of rows

 

2

2

2

2

 

Fin spacing

mm

1.5

1.5

1.5

1.7

 

Fin type

 

 

Hydrophilic aluminium

 

Indoor coil

Tube outside dia.

mm

Ø7

Ø7

Ø7

Ø9.53

Tube Material

 

 

Innergroove tube

 

 

 

 

 

 

Coil length x height

mm

700x26x350

700x26x350

700x26x350

800x254x44

 

x width

 

 

 

 

 

 

 

Number of circuits

 

4

4

4

3

Indoor air flow (Hi/Mi/Lo)

m3/h

480/410/360

480/410/360

580/480/400

660/550/480

Indoor noise level (Hi/Mi/Lo)

dB(A)

35/32/30

36/33/30

38/35/33

40/38/35

Pipe size

Liquid side/ Gas side

mm

Ø6.35/Ø9.53

Ø6.35/Ø9.53

Ø6.35/Ø12.7

Ø6.35/Ø12.7

 

Dimension (W*H*D)

mm

955×210×385

955×210×385

955×210×385

1,301X210X385

Indoor unit

Packing (W*H*D)

mm

1,114x277x469

1,114x277x469

1,114x277x469

1,114x277x469

 

Net/Gross weight

Kg

15/19

15/19

15/19

18/22

ENGLISH 7

J368-EN.indd 7

 

 

2/1/07 9:40:56 AM

 

 

 

 

 

 

Loading...
+ 16 hidden pages