TECHNICAL GUIDE

SPLIT-SYSTEM

AIR CONDITIONERS

14.5 SEER – R-410A

MODELS: TCGF24 THRU 60

(2 THRU 5 NOMINAL TONS, 1 PHASE)

 

ISO 9001

LISTED

Certified Quality

Management System

Due to continuous product improvement, specifications are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at www.ahridirectory.org

413432-YTG-A-0608

DESCRIPTION

The 14.5 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus- tom-matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces and air handlers.

WARRANTY

Single Phase Units:

5-year limited parts warranty.

10-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS - The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for increased efficiency and corrosion protection.

PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature and externally by a factory installed high pressure switch. This protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.

DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.

LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.

TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.

LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolated compressor mounts minimize compressor operating sounds.

LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing.

EASY SERVICE ACCESS - Fully exposed refrigerant connections, and a single panel covering the electrical controls make for easy servicing of the unit.

SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.

U.L. and C.U.L. listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

413432-YTG-A-0608

Physical and Electrical Data

MODEL

 

TCGF24S41S1

TCGF30S41S1

TCGF36S41S1

TCGF42S41S1

TCGF48S41S1

TCGF60S41S1

Unit Supply Voltage

 

 

208-230V,

1φ, 60Hz

 

 

Normal Voltage Range 1

 

 

187 to 252

 

 

Minimum Circuit Ampacity

16.8

18.4

19.09

23.9

27.9

35.9

Max. Overcurrent Device Amps 2

25

30

30

40

45

60

Min. Overcurrent Device Amps 3

20

20

20

25

30

40

Compressor Type

 

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Compressor

Rated Load

12.8

14.1

14.1

17.9

21.1

27.5

Amps

Locked Rotor

58

73

77

112

115

135

Crankcase Heater

 

No

No

No

No

No

No

Fan Motor Amps

Rated Load

.8

.8

1.5

1.5

1.5

1.5

Fan Diameter Inches

22

22

22

24

24

24

 

Rated HP

1/8

1/8

1/4

1/4

1/4

1/4

Fan Motor

Nominal RPM

1075

1075

850

850

850

850

 

Nominal CFM

2750

2800

3200

3600

3600

3700

 

Face Area Sq. Ft.

13.07

17.44

17.44

20.03

21.37

24.04

Coil

Rows Deep

1

1

1

1

1

1

 

Fin / Inches

23

23

23

23

23

23

Liquid Line Set OD

(Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

3/4

3/4

7/8

7/8

1 1/8

Unit Charge (Lbs. - Oz.) 4

3 - 2

3 -

3 - 10

4 - 4

4 - 9

5 - 9

Charge Per Foot, Oz.

0.62

0.62

0.62

0.67

0.67

0.75

Operating Weight Lbs.

TBD

130

145

172

180

199

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.

4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

 

 

All dimensions are in inches. They are subject to change

 

 

without notice. Certified dimensions will be provided upon

C

 

request.

 

 

 

 

 

 

 

Unit

 

Dimensions

 

Refrigerant Connection

 

 

 

(Inches)

 

Service Valve Size

 

 

Model

A1

B

C

Liquid

Vapor

 

 

 

 

 

24

28

29

29

 

 

A

 

30

36

29

29

 

3/4”

 

36

36

29

29

 

 

 

 

3/8”

 

 

 

42

34

33.6

33.6

 

 

 

 

7/8”

 

 

48

36

33.6

33.6

 

 

 

 

 

 

 

60

40

33.6

33.6

 

7/8”2

 

B

1.

Including Fan Guard.

 

 

 

 

2. Adapter fitting required for 1-1/8” line set.

 

 

 

 

2

Johnson Controls Unitary Products

413432-YTG-A-0608

Additional R-410A Charge / Orifice Size for Various Matched Systems

Outdoor Unit

TCGF24S41S1

TCGF30S41S1

TCGF36S41S1

TCGF42S41S1

TCGF48S41S1

TCGF60S41S1

Required Orifice or TXV 1

1TVM902

1TVM903

1TVM903

1TVM903

1TVM905

1TVM906

Factory Charge, lbs-oz

3 - 2

3 - 7

3 - 10

4 - 4

4 - 9

5 - 9

 

 

 

 

 

 

 

Indoor Coil2,3,4

 

 

Additional Charge, Oz

 

 

FC/MC/PC24A3X

5

FC/MC/PC24B3X

5

FC/MC/PC30A3X

12

2

FC/MC/PC30B3X

12

2

FC/MC/PC32A3X

16

10

FC/MC/PC35B3X

16

10

8

FC/MC/PC35C3X

16

10

8

FC/MC/PC36A3X

8

4

1

FC/MC/PC36B3X

8

4

1

FC/MC/PC36C3X

8

4

1

FC/MC/PC37A3X

24

19

15

FC/MC/PC43B3X

24

19

15

5

FC/MC/PC43C3X

24

19

15

5

FC/MC/PC48C3X

40

32

15

17

16

FC/MC/PC48D3X

40

32

27

17

16

FC/MC/PC60D3X

17

16

0

FC/MC62D3X

25

26

18

UC24A3X

8

UC24B3X

8

UC30A3X

8

4

UC30B3X

8

4

UC36A3X

UC36B3X

UC36C3X

UC42B3X

UC42C3X

UC48C3X

UC48D3X

UC60C3X

12

UC60D3X

12

HC18A3X

HC30A3X

10

HC36B3X

16

11

8

HC42C3X

25

19

15

6

HC60D3X

0

0

0

HD24*3X

16

HD36*3X

18

HD48*3X

51

42

36

24

25

HD60*3X

24

AHP18B3X

AHP24B3X

3

AHP30B3X

16

 

AHP36C3X

19

15

AHP42C3X

AHP/SHP60D3X

1

AV24B3X

3

AV36C3X

25

19

15

AV/SV48D3X

9

0

1

AV/SV60D3X

0

1

0

For notes see Page 4.

 

 

 

 

 

 

Johnson Controls Unitary Products

3

413432-YTG-A-0608

Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued)

Outdoor Unit

 

 

TCGF24S41S1

TCGF30S41S1

TCGF36S41S1

TCGF42S41S1

TCGF48S41S1

TCGF60S41S1

Required Orifice or TXV 1

1TVM902

1TVM903

1TVM903

1TVM903

1TVM905

1TVM906

Factory Charge, lbs-oz

3 - 2

3 - 7

3 - 10

4 - 4

4 - 9

5 - 9

 

 

 

 

 

 

 

 

Indoor Coil2,3,4

 

 

Additional Charge, Oz

 

 

F4FP024

 

 

 

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FP030

 

 

 

3

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FP036

 

 

 

8

5

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FP040

 

 

 

12

8

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FP042

 

 

 

8

0

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FP045

 

 

 

9

2

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F5FP048

 

 

 

20

10

11

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F5FP060

 

 

 

20

10

11

 

See Caution below

 

 

 

 

 

 

 

 

 

 

F4FV060

 

 

 

9

10

1

 

See Caution below

FOOTNOTES:

1.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

2.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

3.A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV

4.Refer to Technical Guide for actual system performance for specified matches.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing.

2.Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.

3.Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.

4.For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.

5.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

If the F*FP Air Handler used has a with a factory installed R-22 TXV it MUST BE CHANGED OUT to a R-410A TXV or a orifice for proper operation. If the TXV is not changed out system damage will occur.

4

Johnson Controls Unitary Products

413432-YTG-A-0608

COOLING CAPACITY - With Air Handler Coils

UNIT

AIR HANDLER

 

COIL

 

 

COOLING

 

 

 

 

 

RATED

NET MBH

 

 

MODEL

MODEL

 

W

MODEL1

SEER

EER

 

CFM

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

14.5 SEER AC WITH MA

 

 

 

 

 

MA08B

 

17

FC/MC24B

800

24.8

17.3

14.35

12.15

 

MA08B

 

17

FC/MC30B

800

24.8

17.3

14.35

12.15

TCGF24S41S1

MA08B

 

17

FC/MC35B

800

25.0

17.6

14.50

12.25

 

MA08B

 

17

FC/MC36B

800

25.0

17.6

14.40

12.25

 

MA08B

 

17

FC/MC43B

800

25.2

18.0

14.60

12.35

 

MA12B

 

17

FC/MC30B

1000

28.8

20.6

14.00

12.00

TCGF30S41S1

MA12B

 

17

FC/MC35B

1000

29.0

21.0

14.05

12.00

MA12B

 

17

FC/MC36B

1000

29.0

21.0

14.00

12.00

 

 

 

MA12B

 

17

FC/MC43B

1000

29.6

21.6

14.45

12.00

 

MA12B

 

17

FC/MC35B

1200

34.4

25.4

14.20

12.10

TCGF36S41S1

MA12B

 

17

FC/MC36B

1200

34.2

25.0

14.00

12.00

MA12B

 

17

FC/MC43B

1200

35.2

26.0

14.50

12.30

 

 

 

MA14D

 

24

FC/MC48D

1200

35.6

26.4

14.65

12.35

 

MA16C

 

21

FC/MC43C

1400

40.5

30.4

14.10

12.10

 

MA14D

 

24

FC/MC48D

1400

41.0

30.8

14.40

12.30

TCGF42S41S1

MA16C

 

21

FC/MC48C

1400

41.0

30.8

14.40

12.30

MA14D

 

24

FC/MC60D

1400

41.0

30.8

14.35

12.10

 

 

 

MA16C

 

21

FC/MC60C

1400

41.0

30.8

14.35

12.10

 

MA14D

 

24

FC/MC62D

1400

41.0

31.0

14.45

12.05

 

MA16C

 

21

FC/MC48C

1600

46.5

32.8

14.50

12.00

 

MA20D

 

24

FC/MC48D

1600

46.5

32.8

14.50

12.00

TCGF48S41S1

MA16C

 

21

FC/MC60C

1600

46.5

32.6

14.50

12.00

 

MA20D

 

24

FC/MC60D

1600

46.5

32.6

14.50

12.00

 

MA20D

 

24

FC/MC62D

1600

47.0

32.8

14.50

12.00

TCGF60S41S1

MA20D

 

24

FC/MC62D

1800

57.0

39.0

14.00

12.10

 

 

 

14.5 SEER AC WITH MV - VARIABLE SPEED

 

 

 

 

MV12B

17

FC/MC24B

800

25.4

17.7

16.00

13.20

 

MV12B

17

FC/MC30B

800

25.4

17.7

16.00

13.20

 

MV12B

17

FC/MC35B

800

25.6

18.0

16.00

13.50

 

MV16C

21

FC/MC35C

800

25.6

18.0

16.00

13.50

TCGF24S41S1

MV12B

17

FC/MC36B

800

25.6

18.0

16.00

13.50

 

MV16C

21

FC/MC36C

800

25.6

18.0

16.00

13.50

 

MV12B

17

FC/MC43B

800

25.8

18.4

16.10

13.75

 

MV16C

21

FC/MC43C

800

25.8

18.4

16.10

13.75

 

MV16C

21

FC/MC48C

800

26.2

18.7

16.50

14.00

 

MV12B

17

FC/MC30B

1000

29.4

21.0

15.00

12.85

 

MV12B

17

FC/MC35B

1000

29.6

21.4

15.25

13.00

 

MV16C

21

FC/MC35C

1000

29.6

21.4

15.50

13.25

 

MV12B

17

FC/MC36B

1000

29.6

21.4

15.30

13.15

TCGF30S41S1

MV16C

21

FC/MC36C

1000

29.6

21.4

15.50

13.15

 

MV12B

17

FC/MC43B

1000

30.2

22.0

15.75

13.25

 

MV16C

21

FC/MC43C

1000

30.2

22.0

16.00

13.50

 

MV16C

21

FC/MC48C

1000

30.6

22.2

16.00

13.50

 

MV20D

24

FC/MC48D

1000

30.6

22.2

16.00

13.50

 

MV12B

17

FC/MC35B

1200

35.0

25.8

15.00

12.50

 

MV16C

21

FC/MC35C

1200

35.2

26.0

15.75

13.00

 

MV12B

17

FC/MC36B

1200

34.8

25.4

15.00

12.75

 

MV16C

21

FC/MC36C

1200

35.0

25.6

15.50

13.00

TCGF36S41S1

MV12B

17

FC/MC43B

1200

35.8

26.4

15.50

13.00

 

MV16C

21

FC/MC43C

1200

36.0

26.6

16.00

13.25

 

MV12D

24

FC/MC48D

1150

36.0

26.4

16.00

13.50

 

MV16C

21

FC/MC48C

1200

36.2

27.0

16.25

14.00

 

MV20D

24

FC/MC48D

1200

36.2

27.0

16.25

14.00

For notes see Page 6.

Johnson Controls Unitary Products

5

413432-YTG-A-0608

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

COIL

 

 

 

COOLING

 

 

 

 

 

RATED

 

NET MBH

 

 

MODEL

MODEL

 

W

MODEL1

 

SEER

EER

 

CFM

 

 

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

14.5 SEER AC WITH MV - VARIABLE SPEED (Contimued)

 

 

 

 

MV16C

 

21

FC/MC43C

1400

 

41.0

30.8

15.00

12.75

 

MV16C

 

21

FC/MC48C

1400

 

41.5

31.2

15.50

13.00

TCGF42S41S1

MV20D

 

24

FC/MC48D

1400

 

42.0

31.4

15.50

13.00

 

MV20D

 

24

FC/MC60D

1400

 

41.5

31.4

15.50

13.00

 

MV20D

 

24

FC/MC62D

1400

 

42.0

31.4

15.75

13.00

 

MV16C

 

21

FC/MC48C

1600

 

47.0

33.0

15.25

12.75

TCGF48S41S1

MV20D

 

24

FC/MC48D

1600

 

47.0

33.0

15.25

12.75

MV20D

 

24

FC/MC60D

1600

 

47.0

33.0

15.25

12.75

 

 

 

 

MV20D

 

24

FC/MC62D

1600

 

47.5

33.2

15.25

12.75

TCGF60S41S1

MV20D

 

24

FC/MC60D

1800

 

55.0

39.0

14.00

11.95

MV20D

 

24

FC/MC62D

1800

 

57.0

39.5

14.50

12.25

 

 

 

 

 

14.5 SEER AC WITH AV / SV / F*FV - VARIABLE SPEED

 

 

 

TCGF24S41S1

AV24

 

17

-

750

 

25.0

17.5

15.75

13.25

AV36

 

21

-

750

 

25.8

18.2

16.50

13.75

 

 

 

TCGF30S41S1

AV36

 

21

-

1000

 

30.4

22.4

16.25

13.50

 

AV36

 

21

-

1250

 

36.2

27.4

15.75

13.25

TCGF36S41S1

AV/SV48

 

24

-

1200

 

34.4

25.4

15.25

13.00

 

F4FV060

 

24

-

1200

 

34.6

25.6

15.50

13.25

 

AV/SV48

 

24

-

1400

 

40.0

29.4

14.75

12.50

TCGF42S41S1

AV/SV60

 

24

-

1400

 

40.0

29.4

14.75

12.50

 

F4FV060

 

24

-

1350

 

40.0

29.6

15.00

12.50

 

AV/SV48

 

24

-

1600

 

44.5

30.8

14.25

12.00

TCGF48S41S1

AV/SV60

 

24

-

1650

 

44.0

30.6

14.25

12.00

 

F4FV060

 

24

-

1600

 

44.5

30.6

14.25

12.00

TCGF60S41S1

AV/SV60

 

24

-

1750

 

55.0

39.0

14.00

12.00

 

 

 

14.5

SEER AC WITH AHP / SHP / F*FP

 

 

 

 

TCGF24S41S1

AHP24

 

17

-

850

 

24.8

17.4

14.30

12.20

F4FP030

 

17

-

800

 

24.8

17.2

14.30

12.20

 

 

 

TCGF30S41S1

AHP36

 

21

-

1000

 

29.6

21.4

14.30

12.20

 

AHP36

 

21

-

1200

 

35.4

26.2

15.00

12.50

 

F4FP036

 

21

-

1200

 

34.2

25.2

14.00

12.00

TCGF36S41S1

F4FP040

 

21

-

1200

 

34.4

25.0

14.00

12.00

F4FP042

 

21

-

1200

 

34.4

25.0

14.00

12.00

 

 

 

 

F5FP048

 

24

-

1250

 

36.4

27.4

16.25

13.50

 

F5FP060

 

24

-

1250

 

34.8

26.0

15.25

13.00

TCGF42S41S1

F5FP048

 

24

-

1450

 

42.0

32.0

15.50

13.00

F5FP060

 

24

-

1500

 

40.0

29.8

14.75

12.50

 

 

 

 

AHP/SHP60

 

24

-

1600

 

44.0

30.6

14.20

12.00

TCGF48S41S1

F5FP048

 

24

-

1700

 

47.5

34.0

15.00

12.75

 

F5FP060

 

24

-

1700

 

44.5

31.2

14.00

12.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

6

Johnson Controls Unitary Products

413432-YTG-A-0608

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

 

FURNACE**

COIL

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

 

RATED

NET MBH

SEER1

 

W

MODEL

EER

 

(Min.-max.)

CFM

 

 

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600 - 1000

14,17

FC/MC/PC24

800

24.8

17.3

14.00

12.00

 

600 - 1000

14,17

FC/MC/PC30

800

24.8

17.3

14.00

12.00

 

600 - 1000

14

FC/MC/PC32

800

25

17.6

14.50

12.35

 

600 - 1000

17,21

FC/MC/PC35

800

25

17.6

14.50

12.35

 

600 - 1000

14,17,21

FC/MC/PC36

800

25

17.6

14.00

12.00

 

600 - 1000

14

FC/MC/PC37

800

25.4

17.9

14.50

12.35

 

600 - 1000

17,21

FC/MC/PC43

800

25.2

18

14.70

12.50

 

600 - 1000

21

FC/MC/PC48

800

25.6

18.3

14.80

12.65

TCGF24S41S1

600 - 1000

14

HC18

800

24.2

16.7

14.00

12.00

 

600 - 1000

14

HC30

800

24.8

17.4

14.00

12.00

 

600 - 1000

17

HC36

800

25

17.6

14.00

12.00

 

600 - 1000

21

HC42

800

25.4

18

14.50

12.35

 

600 - 1000

14,17

HD24

800

25.4

17.7

14.50

12.35

 

600 - 1000

14,17,21

HD36

800

24.8

17

14.00

12.00

 

600 - 1000

21

HD48

800

25.6

17.9

14.50

12.35

 

600 - 1000

14,17

UC24

800

25

17.5

14.00

12.00

 

600 - 1000

14,17

UC30

800

25

17.5

14.00

12.00

 

800 - 1200

14,17

FC/MC/PC30

1000

28.8

20.6

14.00

12.00

 

800 - 1200

14,17

FC/MC/PC32

1000

29

21

14.00

12.00

 

800 - 1200

17,21

FC/MC/PC35

1000

29

21

14.00

12.00

 

800 - 1200

14,17,21

FC/MC/PC36

1000

29

21

14.00

12.00

 

800 - 1200

14

FC/MC/PC37

1000

29.6

21.6

14.50

12.35

TCGF30S41S1

800 - 1200

17,21

FC/MC/PC43

1000

29.6

21.6

14.50

12.35

800 - 1200

21,24

FC/MC/PC48

1000

30

21.8

14.50

12.35

 

 

800 - 1200

17

HC36

1000

29

21

14.00

12.00

 

800 - 1200

21

HC42

1000

29.6

21.6

14.25

12.10

 

800 - 1200

14,17,21

HD36

1000

28.8

20.2

14.00

12.00

 

800 - 1200

21,24

HD48

1000

29.8

21.4

14.50

12.35

 

800 - 1200

14,17

UC30

1000

29

20.8

14.00

12.00

 

1000 - 1400

17,21

FC/MC/PC35

1200

33.6

24.6

14.00

11.90

 

1000 - 1400

14,17,21

FC/MC/PC36

1200

33.4

24.2

14.00

11.85

 

1000 - 1400

14

FC/MC/PC37

1200

34.4

25.2

14.50

12.20

 

1000 - 1400

17,21

FC/MC/PC43

1200

34.4

25.2

14.50

12.20

TCGF36S41S1

1000 - 1400

21,24

FC/MC/PC48

1200

34.6

25.4

14.50

12.25

 

1000 - 1400

17

HC36

1200

33.6

24.6

14.00

11.90

 

1000 - 1400

21

HC42

1200

34.4

25.2

14.50

12.20

 

1000 - 1400

14,17,21,24

HD48

1200

34.6

25

14.50

12.20

 

1000 - 1400

21,24

UC60

1200

33.2

23.8

14.00

11.75

 

1200 - 1600

17,21

FC/MC/PC43

1400.00

40.50

30.40

14.00

12.00

 

1200 - 1600

21,24

FC/MC/PC48

1400.00

41.00

30.80

14.50

12.30

 

1200 - 1600

21,24

FC/MC/PC60

1400.00

41.00

30.80

14.50

12.30

TCGF42S41S1

1200 - 1600

21

HC42

1400.00

40.50

30.40

14.00

12.00

 

1200 - 1600

14,17,21,24

HD48

1400.00

41.00

30.40

14.25

12.10

 

1200 - 1600

21,24

HD60

1400.00

41.50

31.20

14.50

12.30

 

1200 - 1600

21,24

FC/MC62

1400.00

41.00

31.00

14.50

12.30

 

1400 - 1800

21,24

FC/MC/PC48

1600.00

46.50

32.80

14.25

12.10

 

1400 - 1800

21,24

FC/MC/PC60

1600.00

46.50

32.60

14.50

12.35

TCGF48S41S1

1400 - 1800

14,17,21,24

HD48

1600.00

46.50

32.60

14.50

12.35

 

1400 - 1800

14,17,21,24

HD60

1600.00

47.50

33.20

14.50

12.35

 

1400 - 1800

21,24

FC/MC62

1600.00

47.00

32.80

14.50

12.35

 

1600 - 2000

21,24

FC/MC/PC60

1800.00

54.50

38.50

13.80

11.90

TCGF60S41S1

1600 - 2000

24

HC60

1800.00

54.50

38.50

13.50

11.65

 

1600 - 2000

21,24

FC/MC62

1800.00

57.00

39.00

14.00

12.10

1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.

Johnson Controls Unitary Products

7