Models 200 / 210 / 220 / 240 / 250 / 270 / 280

This product is for use only in Great Britain and Ireland (GB, IE)

These instructions are to be left with the customer, should be read carefully and kept in a safe place.

They will be necessary when servicing the appliance.

IMPORTANT

Before installation of this product please read these instructions fully.

The installer should complete the commissioning sheet at the start of the User Instructions.

PM173 Issue 2 (August 2006)

Contents

Welcome to Yeoman

Commissioning Data

Technical Specification

3

4

5

SITE REQUIREMENTS

Stove Dimensions

6

Hearth Dimensions

7

Walls adjacent to Hearths

7

PRE-INSTALLATION CHECKS

Flue or Chimney

Additional Ventilation

8

9

INSTALLATION INSTRUCTIONS

Installing the Stove

Commissioning

10

11

OPERATING INSTRUCTIONS

General

12

Using the stove for the first time

12

Burning Wood

12

Burning Solid Fuel

13

Ash Removal

13

Recommended Fuels

14

MAINTENANCE AND SERVICING

 

General Cleaning

15

Cleaning Glass

15

Chimney Sweeping

15

Annual Service

15

2

Welcome to Yeoman

Your new Elegance multi-fuel stove is perhaps the most advanced design of modern stoves. Owning such a stove shows appreciation for exceptional quality.

Please read your manual thoroughly, its purpose is to familiarise you with your stove, and give guidelines for its installation, operation and maintenance. If after reading this manual you need further information, please do not hesitate to contact your Yeoman dealer.

IMPORTANT NOTICE

If your stove is installed correctly, it will give you many years of excellent service for which it was designed. This appliance must be installed by a HETAS registered installer (GB only).

WARNING

All types of heating appliance can be potentially dangerous. Correct installation and operating procedures must be observed when fitting this stove. Some parts of your stove are protected on their surface with heat proof paint. When the stove is first used it is normal for it to emit some light smoke, with an unpleasant smell. Though unpleasant, this is non toxic and is produced only whilst the stove paint fully cures. We recommend that you ventilate the room until this disappears.

3

FOR YOUR RECORDS

To assist us in any Guarantee claim please complete the following information:-

YEOMAN DEALER APPLIANCE WAS PURCHASED FROM

Name: ..................................................................................................................................................................................................

Address:...............................................................................................................................................................................................

.............................................................................................................................................................................................................

Telephone number:....................................................................................................................................................

ESSENTIAL INFORMATION - MUST BE COMPLETED

Date installed:......................................................................................................................................................................................

Model Description:..............................................................................................................................................................................

Serial number: ..........................................................................................................................................................

INSTALLATION ENGINEER

Company name:...................................................................................................................................................................................

Address:...............................................................................................................................................................................................

.............................................................................................................................................................................................................

Telephone number: ....................................................................................................................................................................

COMMISSIONING CHECKS (TO BE COMPLETED AND SIGNED)

Is flue system correct for the appliance

YES

NO

Flue swept and soundness test complete

YES

NO

Smoke test completed on installed appliance

YES

NO

Spillage test completed

YES

NO

Use of appliance and operation of controls explained

YES

NO

Instruction books handed to customer

YES

NO

Signature: ........................................................................................................

 

Print name:......................................................

4

TECHNICAL SPECIFICATION

Model

 

 

 

 

 

 

 

 

 

 

 

Elegance 200

YM-EL200

200

 

210

220

240

250

270

 

280

Elegance 210

YM-EL210

 

 

 

 

 

 

 

 

 

 

 

Elegance 220

YM-EL220

Elegance

 

Elegance

Elegance

Elegance

Elegance

Elegance

 

Elegance

Elegance 270

YM-EL270

 

 

Elegance 240

YM-EL240

 

 

 

 

 

 

 

 

 

Elegance 250

YM-EL250

 

 

 

 

 

 

 

 

 

Elegance 280

YM-EL280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Heat Output

 

kW

4.9

 

4.9

7

4.9

6

6

 

8

 

 

 

 

 

 

 

 

 

 

 

Flue Draught at Nominal Heat

mm Wg

1.5

 

1.5

1.5

1.5

1.5

1.5

 

1.5

Output

 

Inch Wg

0.06

 

0.06

0.06

0.06

0.06

0.06

 

0.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Gas Mass Flow

 

g/s

6.3

 

6.3

6.3

6.8

6.8

6.8

 

7.4

 

 

 

 

 

 

 

 

 

 

 

 

Flue Gas Temperature at

°C

290

 

290

290

290

290

290

 

270

 

 

 

 

 

 

 

 

 

 

Spigot/Socket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Outlet Size

 

mm

150

 

150

150

150

150

150

 

150

 

inch

6

 

6

6

6

6

6

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Position

 

 

Top

 

Top

Top

Top

Top

Top

 

Top

 

 

Only

 

Only

Only

Only

Only

Only

 

Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

kg

76

 

81

85

75

90

103

 

155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

Seasoned wood (less than 20% moisture content).

 

Recommended Fuels

 

 

Briquette smokeless fuel suitable for closed appliances.

 

Solid Fuel

 

(Ancit - Phurnacite - Taybrite - Homefire Ovals).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Yeoman 280, 210, 200, 220, 270 User Manual

SITE REQUIREMENTS

Before installation of this product please read these instructions fully.

It is very important to also understand the requirements of the UK Building Regulations (England and Wales - Document J / Scotland - Part F), along with any local regulations and working practices that may apply. Should any conflict occur between these instructions and these regulations then the regulations shall apply.

All electrical connections should meet the requirements of UK Building Regulations (England and Wales - Document P / Scotland - Part N).

Your local Building Control Office would be happy to advise, should questions arise regarding the requirements of the regulations.

The Elegance Stove should be fitted by a HETAS (GB only) registered installer, or approved by your local building control officer. Your Yeoman dealer should be able to arrange this service for you.

Your building insurance company may also require you to inform them that you have installed a new heating appliance, so check with your insurers that your cover is still valid after installing the Elegance Stove.

When completing the installation and building works you should comply with your responsibilities under the Health and Safety at Work Acts, and any new regulations, which may be introduced during the lifetime of these instructions.

A faulty installation could cause danger to the inhabitants and structure of the building.

ELEGANCE STOVE DIMENSIONS

Elegance 200

Elegance 220

 

 

Elegance 210

Elegance 240

6

SITE REQUIREMENTS

Elegance 250

Elegance 280

 

 

 

 

Elegance 270

7

SITE REQUIREMENTS

Additional information covering the installation of the Elegance stove may be found in the British Standard: BS8303.

HEARTH DIMENSIONS

The appliance must stand on a constructional hearth with the minimum dimensions as shown in diagram below.

 

 

 

 

 

Solid, non combustable

 

Yeoman Elegance

material e.g concrete or

 

 

 

 

 

 

 

masonry

 

 

 

 

 

 

 

 

 

A

150mm

 

minimum

C

 

C

150mm

 

 

 

 

 

 

 

 

 

 

 

minimum

 

Wall Thickness W

If you are fitting the appliance into an existing hearth setting, check that it complies with the current construction regulations and is at least the minimum sizes shown.

If you have no existing fireplace or chimney, it is possible to construct a suitable non-combustible housing and hearth setting. However this should be constructed to comply with the requirements of both current national and local regulations with the design approved by your local building control officer. Masonry chimney systems built with clay or concrete liners or pre-fabricated block systems should be constructed in accordance with BS 6461 : Part 1. Factory made insulated systems should comply with BS 4543 : Part 2 and be installed to BS 7566 : Parts 1 to 4.

Remember that any new chimney added to your property may also require planning permission.

WALLS ADJACENT TO HEARTHS

150mm minimum

150mm minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

225mm

 

150mm

 

 

 

minimum

 

minimum

 

 

Constructional

 

 

 

Constructional

hearth 840mm

 

Change in level to

 

 

hearth 840mm

minimum

 

 

 

minimum

 

mark safe perimeter

 

 

 

 

 

 

 

 

 

 

 

Location of hearth

Solid, non-combustible material

or Elegance Stove

Thickness (W)

Height (A)

 

 

 

Where the hearth

 

At least 300mm

abuts a wall and the

 

 

above the

Elegance Stove is

 

200mm

Elegance Stove

not more than

 

and 1200mm

50mm from the

 

 

above the hearth

wall

 

 

 

 

 

 

Where the hearth

 

At least 300mm

abuts a wall and the

 

 

above the

Elegance Stove is

75mm

Elegance Stove

more than 50mm

 

 

and 1200mm

but not more than

 

 

above the hearth

300mm from the

 

 

 

wall

 

 

 

 

 

Where the hearth

 

 

does not abut a wall

75mm

At least 300mm

and is no more

above the hearth

 

than 150mm from

 

 

the wall

 

 

Note: there is no requirement for protection of the wall where C is more than 150mm

8