YCL NAD-1503, NAD-1504, NAD-1502, NAD-1501, NAD-1505 Datasheet

0 (0)
YCL NAD-1503, NAD-1504, NAD-1502, NAD-1501, NAD-1505 Datasheet

15Watts Open Frame Single Output

NAD-150X series

Feature:

90 to 264Vac universal input range.

UL/CUL, TUV, CE safety approval.

EMI/RFI meet VDE & FCC limit B.

Low cost & compact size.

15Watts in 98.3×46×27mm Size.

2 Year Warranty.

Specifications: typical at nominal line, full load at 25°C.

 

Input Specifications:

General Specifications:

Input voltage: 90 to 264Vac

Efficiency: 70% typical at full load

 

 

Input Frequency: 47 Hz to 63Hz

Hold-up time: 15ms @ 115Vac full load

 

 

Input inrush current: 20A at 115Vac

EMI/RFI: VDE & FCC Class B limits

 

 

40A at 230Vac

 

 

 

Dielectric Withstand:

 

 

 

 

 

 

Input/output: 3000Vac

Earth leakage: 0.2mA max @ 115Vac

Input/Ground: 1500Vac

 

0.4mA max @ 230Vac

 

 

 

Output Specifications:

¬Safety Approval: UL/CUL UL60950

Output Rating: See Rating Charts

TUV EN60950

 

 

 

CE EN55022&50082-1

Output Voltage Accuracy: ± 5% max.

 

 

 

Line Regulation: ± 1% max

Switching frequency: 20kHz(reference)

 

 

Load Regulation: ± 1% max.

Weight: 150g(5.3Oz)

(Full to half load)

 

 

Transient Response: ± 1% max.dev.

MTBF: 100,000hours(MIL-HDBK-217F)

(Full to half load)

500uS recovery

 

Environmental Specifications:

Temperature Coefficient: ± 0.04% / °C

Operating temperature: 0 to +50°C

 

 

Ripple & Noise: 2% P-P max

Storage temperature: -20 to +85°C

 

 

 

Protections:

 

Humidity: 5 to 95 % RH non-condensing

 

a. Short

circuit protection

 

 

Vibration: 2.4G , 5 to 500Hz

 

b. Over power protection

 

 

 

c. Over voltage protection

Cooling: Free air convection

Note:

1.Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.

2.Maximum output power is 15W.

3.At least 20% of load is required to obtain stable regulation.

4.Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap

& a 10uF tantalum or electrolytic cap in parallel with a 20MHz bandwidth oscilloscope directly.

¬Please refer the safety approval status on appendix 1, For latest safety approval status Please consult YCL or visit" www.ycl.com.tw"

Date: Sep 19,2003

1