YCL ADE-1505PM, ADE-1505PLM, ADE-1505PLFI, ADE-1505PLF, ADE-1505PGS Datasheet

...
0 (0)
YCL ADE-1505PM, ADE-1505PLM, ADE-1505PLFI, ADE-1505PLF, ADE-1505PGS Datasheet

15Watts Single Output External Adapter ADE-150X series

Feature:

90 to 264Vac universal input range.

UL/CUL,TUV safety meet(approval).

EMI/RFI meet VDE & FCC limit B.

Low cost & compact size.

15Watts in 105.8×57.5×33.2mm Size.

2 Year Warranty.

Specifications: typical at nominal line, full load at 25°C.

 

Input Specifications:

General Specifications:

Input voltage: 90 to 264Vac

Efficiency: 70% typical at full load

 

 

Input Frequency: 47 Hz to 63Hz

Hold-up time: 10ms @ 115Vac full load

 

 

Input inrush current: 20A at 115Vac

EMI/RFI: VDE & FCC Class B limits

 

40A at 230Vac

 

 

Dielectric Withstand:

 

 

Earth leakage: 0.2mA max @ 115Vac

Input/output: 3000Vac

 

0.4mA max @ 230Vac

Input/Ground: 1500Vac

 

Output Specifications:

Safety Meet(approval):

 

 

UL/CUL UL60950

Output Rating: See selection table

TUV EN60950

 

 

Output Voltage Accuracy : ± 5% max.

 

Line Regulation: ± 1% max.

Switching frequency: 35kHz

Load Regulation: ± 5% max.

Weight: 200g

(Full to half load)

 

Transient Response: ± 1% max.dev.

MTBF: 100,000hours(MIL-HDBK-217F)

(Full to half load) 500uS recovery

 

Environmental Specifications:

Temperature Coefficient: ± 0.04% / °C

Operating temperature: 0 to +40°C

Ripple & Noise: 2% P-P max

Storage temperature: -20 to +85°C

Protections:

Humidity: 5 to 95 % RH non-condensing

 

a. Over voltage protection

 

 

Vibration: 2.4G , 5 to 500Hz

 

b. Over power protection

 

 

 

c. Short circuit protection

Cooling: Free air convection

Note:

 

1.Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.

2.Maximum output power is 15W.

3.At least 20% of load is required to obtain stable regulation.

4.Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap & a

10uF tantalum or electrolytic cap in parallel with a 20MHz bandwidth oscilloscope directly. ¬ Please refer the safety approval status on appendix 1, For latest safety approval status

Please consult YCL or visit" www.ycl.com.tw