Yamato Scientific HF200 Heating Block User Manual

Loading...

Heating Block

Type HF100/200

First Edition

Yamato Scientific Co., Ltd.

Contents

1.Name and Function of Components .....................................................

1

Main body ...........................................................................

1

Operation panel ......................................................................

2

Description of characters displayed in the temperature controller ............................

3

2.Operation Method.....................................................................

4

Preparation ..........................................................................

4

List of operation modes and functions ...................................................

5

Fixed-value operation continuous operation mode ......................................

6

Quick auto-stop operation..............................................................

8

Auto-stop operation ..................................................................

11

Auto-start operation ..................................................................

15

Other functions ......................................................................

19

3. In Case of Trouble ...................................................................

23

Error display ........................................................................

23

Troubleshooting guide................................................................

23

4. Specifications .......................................................................

24

5. Wiring Diagram .....................................................................

25

1.Name and Function of Components

Main body

Hand grip for aluminum block

Aluminum block mounting portion (Aluminum block available separately)

Operation panel

Power cord

Serial No. plate

Leg

Temperature controller

Power switch (circuit breaker)

Heating Block

HF100

1

1. Name and Function of Components

 

 

 

Operation panel

 

 

 

 

 

 

Measured Temp.

POWER

 

Fixed Temp.

 

 

Auto Stop

 

 

 

 

Auto Start

 

 

 

 

 

 

 

 

 

Heater

Alarm

Set Temp.

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

Name

Function

 

 

 

 

 

 

 

 

 

Measured temperature display

Displays the bath measured temperature, set mode

 

 

character, alarm temperature.

 

Set temperature display

Displays the set temperature, timer set time, remaining

 

 

timer-operation time, character to set the sub-menu.

 

Start/stop key

Used to start/stop operation.

 

 

Keep pressing for one second.

 

key

Used to increment the set value.

 

 

 

 

 

 

 

 

 

key

Used to decrement the set value.

 

 

 

 

 

 

 

 

 

Timer key

Used to set the timer and sub-menu.

 

Sub-menu selector key

Keep pressing the key for four seconds, and such

 

 

functions as key lock, calibration offset temperature

 

 

setting, and power failure compensation selection can be

 

 

set.

 

Alarm lamp

Flashes in case of alarm

 

 

 

 

 

 

 

 

 

Heater lamp

ON when the heater output is ON

 

 

 

 

 

 

 

 

 

Fixed-value operation lamp

ON during the fixed-value operation

 

 

 

 

 

 

 

 

 

Auto start operation lamp

ON during auto-start operation with the

 

 

 

key

 

TIMER

 

 

 

 

 

 

 

 

 

Auto stop operation lamp

ON during auto-stop operation with the

 

 

 

key

 

 

TIMER

 

 

 

 

 

Power switch

ON to turn ON system power supply and OFF to turn OFF

 

 

system power supply. Circuit breaker to turn OFF power

 

 

supply at over-current

2

1. Names and functions of parts

Description of characters displayed in the temperature controller

The controller uses a display of 7-segment LED. Characters to display operation functions are indicated in the “Measured Temp.” screen.

Character displays and corresponding meanings are described below.

Auto-stop or Auto-start operation can be selected with the TIMER key.

Character

Identifier

 

Name

 

Meaning

 

 

Timer menu mode

 

Means that the auto-stop operation

 

AStP

Timer

setting

mode

 

 

display

 

 

has been selected.

 

 

 

 

 

 

End

Time-up

 

 

Means that the auto-stop operation

 

 

 

has ended.

 

 

 

 

 

 

 

 

 

 

 

 

Timer menu mode

 

Means that the auto-start operation

 

AStr

Timer

setting

mode

 

 

display

 

 

has been selected.

 

 

 

 

 

Function settings as follows can be made from the sub-menu.

Keep pressing the TIMER key for four seconds, and the mode changes to the sub-menu mode. To return to the original screen, keep pressing the TIMER key.

 

LocK

Sub-menu mode

 

Function to lock so as to prevent

 

Locked at fixed value

changing of the set contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub-menu mode

 

Temperature compensation function

 

cAL

 

to

allow

the

aluminum

block

 

Calibration offset

temperature to agree with the

 

 

 

 

 

 

control temperature (see page 23)

 

 

Sub-menu mode

 

Function to select whether the

 

Pon

Power

failure

recovery from power failure is to be

 

 

compensation selection

made automatically or manually.

 

 

 

 

Sub-menu mode

 

Select

ON

with

the

key

to

 

on

Locking the setting

activate lock to prevent change of

 

Power

failure

the setting and when the recovery

 

 

compensation

selection

from power failure is to be made

 

 

auto reset

 

automatically.

 

 

 

 

 

 

 

 

Sub-menu mode

 

Select

OFF

with

the

key

to

 

 

Canceling locking of the

 

off

setting

 

cancel

locking

to

enable

free

 

 

change of the setting and when the

 

Power

failure

 

 

compensation

selection

recovery from power failure is to be

 

 

manual reset

 

made manually.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two characters to indicate that operation is not possible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection of the mode that is

 

nG

Operation impossible

inoperable during operation causes

 

display of nG in the set temperature

 

 

 

 

display, rejecting any attempt of

 

 

 

 

change.

 

 

 

 

 

 

 

 

 

 

 

Attempt to change the mode while

 

Loc

Sub-menu mode

 

the

LocK function

is

ON

causes

 

 

display

of

Loc

in

the

 

set

 

Locking the set contents

 

 

 

temperature

display, rejecting

any

 

 

 

 

 

 

 

 

attempt of change.

 

 

 

 

 

3

2.Operation Method

Preparation

From mounting of the aluminum block to operation start

1.Mounting the aluminum block

Hand grip for aluminum block

2.Connecting the power cord

3.Installing the sample

4.Turning ON power supply

5.Starting operation

Use the dedicated aluminum block available separately.

The use of an attached dedicated hand grip will prove convenient for mounting/removal of the aluminum block.

Caution Possible hazard of burn. Use the hand grip when the aluminum block is sufficiently cooled.

Do not raise the temperature while keeping the hand grip left attached.

If necessary, a bar thermometer may be inserted into a thermometer hole (used also for attaching the hand grip) of the aluminum block.

(Use the thermometer of maximum 200 or more. Since the bar thermometer is not attached, obtain it separately.)

Bar thermometer

Connect the power cord to an appropriate receptacle firmly. The receptacle to be connected must be of a 100V 15A type.

To maintain the temperature accuracy, use a sample container appropriate in size to the sample installation hole of the aluminum block.

Turn ON the POWER switch of the main body and set the desired temperature using▲▼ keys of the operation panel.

Press the START/STOP key of the operation panel for one second, and the operation begins.

Aluminum block, which is available separately

The following types of aluminum blocks are available for HF100/HF200. Be sure to use the aluminum block dedicated to the product concerned.

Specify the product code No. when purchasing.

Product code

Name/size

No. of blocks that

 

 

 

 

 

can be set

 

 

 

213173

For 0.5m micro tube

48

Can

be

used

213174

For 1.5m micro tube

36

commonly

for

213181

For 12 test tube

36

HF21/41/61

 

213182

For 15 test tube

25

 

 

 

213183

For 16.5 test tube

25

 

 

 

213184

For 18 test tube

20

 

 

 

213175

For 21 test tube

12

 

 

 

213176

For 24 test tube

12

 

 

 

213185

For 25 test tube

12

 

 

 

213177

For 30 test tube

8

 

 

 

4

2. How to operate the unit

List of operation modes and functions

The operation functions of the product are as follows.

Nomenclature

 

Description

Page

1

Fixed-value operation

Continuous operation mode

P.6

 

 

 

 

Press the

START/STOP

key for one second after temperature

 

 

 

 

 

setting, and the continuous operation begins. Pressing the

 

 

 

 

 

START/STOP

key again for one second causes stop of

 

 

 

 

 

operation.

 

2

Quick

auto-stop

 

Causes activation of the timer halfway of fixed-value

P.8

 

operation

 

 

operation, then automatic operation stop after the set period.

 

 

 

 

 

This function is used “to set the automatic stop after the set

 

 

 

 

 

time”, “to set, in the course of operation, the automatic stop in

 

 

 

 

 

several hours.”

 

3

Auto-stop operation

Used “to set the automatic stop at the specified time” before

P.11

 

 

 

 

starting the operation. In the auto-stop mode, the timer starts

 

 

 

 

 

counting when the set temperature is reached.

 

4

Auto-start operation

Used to start the automatic operation in several hours, that is,

P.15

 

 

 

 

“to set the automatic start at the specified time.”

 

The temperature and timer’s set time can be changed during operation.

Cautions for the auto-stop operation

The timer does not start counting till the bath temperature reaches the set level.

When the set temperature is below the bath temperature, the timer does not start counting till the bath temperature drops below the set temperature.

The operation functions of sub-menu of the product are as follows.

 

 

Keep pressing the

 

key for four seconds. The mode changes to the sub-menu mode.

TIMER

 

 

 

 

 

 

 

 

 

 

1

Calibration

offset

 

The calibration offset function is to compensate for

any

P.21

 

function

 

 

 

difference occurring between the target bath temperature and

 

 

 

 

 

 

controller control temperature (sensor temperature).

 

 

 

 

 

 

 

Compensation can be made either to the positive or negative

 

 

 

 

 

 

side over the entire temperature range of the system.

 

 

2

Power

failure

 

This is a function to select automatic or manual return to the

 

 

compensation selection

 

operation state after power failure.

 

 

 

function

 

 

 

Automatic return with

 

ON and manual return

with

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The operation function of this device is as follows.

Nomenclature

Description

Page

1

Over-temperature

The automatic over-temperature preventive function is

P.19

 

preventive function

incorporated.

 

 

 

When the bath temperature rises excessively along with the

 

 

 

set temperature of the device, this is set to activate

 

 

 

automatically at +12 .

 

 

 

Stop operation when this function is activated. The Alarm

 

 

 

lamp flashes. To cancel, turn ON the power switch newly

 

 

 

again (manual reset).

 

5