XD010-24S |
PRELIMINARY |
10W, 1930-1990MHz |
QuikPAC Module Data |
CDMA Driver Amplifier |
General description:
The XD010-24S QuikPAC™ 10W power module is a 2-stage Class A/AB amplifier module for use in the driver stages of CDMA RF power amplifiers for cellular base stations. The power transistors are fabricated using Xemod’s latest, high performance LDMOS process. This unit operates from a single voltage and has internal temperature compensation of the bias voltage to ensure stable performance over the full temperature range.
Features:
Single Voltage Operation High Gain
High Efficiency
Advanced, XeMOS II LDMOS FETS Stable Performance
50 Ω RF impedance QuikPAC System Compatible
Standard Operating Conditions
Parameter |
Symbol |
Min |
Nom |
Max |
Units |
Frequency Range |
F |
1930 |
|
1990 |
MHz |
Supply (Drain) Voltage |
VD |
|
28 |
|
VDC |
Input and Output Impedance |
Ω |
|
50 |
|
Ohms |
Load Impedance for Stable Operation (All Phases) |
VSWR |
|
|
10:1 |
|
Baseplate Temperature |
TOP |
-20 |
|
+90 |
ºC |
Maximum Ratings
Parameter |
|
|
Symbol |
|
|
Value |
|
Units |
||
Supply (Drain) Voltage |
|
|
VDD |
|
|
35 |
|
VDC |
||
Input RF Power |
|
|
PIN |
|
|
+20 |
|
dBm |
||
Load Impedance for continuous operation without damage |
|
|
VSWR |
|
|
5/1 |
|
|
||
Output Device Channel Temperature |
|
|
|
|
|
|
200 |
|
ºC |
|
Lead Temperature during reflow soldering |
|
|
|
|
|
|
+210 |
|
ºC |
|
Storage Temperature |
|
|
TSTG |
|
-40 to +100 |
|
ºC |
|||
Performance at 25ºC |
|
|
|
|
|
|
|
|
|
|
Parameter |
Symbol |
|
Min |
|
Nom |
|
Max |
|
Units |
|
Supply Voltage |
VD1,2 |
|
27.8 |
|
28.0 |
|
28.2 |
|
VDC |
|
Power Output at 1 dB Compression (single tone) |
P-1 |
|
8.0 |
|
10.0 |
|
|
|
W |
|
Gain at 1W Output (CW) |
G |
|
27.5 |
|
29.0 |
|
|
|
dB |
|
Gain Flatness over frequency at 1W Output (CW) |
∆ G |
|
|
|
0.15 |
|
0.5 |
|
dB |
|
Input Return Loss at 1W Output (CW) (50 Ω Ref) |
iRL |
|
10 |
|
14 |
|
|
|
dB |
|
Quiescent Current (total) |
IDQ |
|
|
|
380 |
|
|
|
mA |
|
Drain Efficiency at 10W CW output |
η D |
|
|
|
26.0 |
|
|
|
% |
|
Drain Efficiency at 1W CDMA output (Single Carrier IS-95B) |
η D |
|
|
|
6.5 |
|
|
|
% |
|
ACPR at 1W CDMA Power Output (Single Carrier IS-95B) |
|
|
|
|
-58 |
|
|
|
dB |
|
3rd order IMD at 10W PEP (twotone; 1MHz ∆ F) |
|
|
|
|
-32 |
|
-27 |
|
dBc |
|
Electrical Delay |
|
|
|
|
2.9 |
|
|
|
ns |
|
|
|
|
|
|
|
|
|
|
|
|
Transmission Phase Flatness |
|
|
|
|
0.5 |
|
|
|
deg. |
XEMOD RESERVES THE RIGHT TO MAKE CHANGES TO THIS SPECIFICATION WITHOUT FURTHER NOTICE. BEFORE THE PRODUCT DESCRIBED HERE IS WRITTEN INTO SPECIFICATIONS OR USED IN CRITICAL APPLICATIONS, THE PERFORMANCE CHARACTERISTICS SHOULD BE VERIFIED BY CONTACTING XEMOD.
Xemod QuikPAC Data |
www.xemod.com |
Rev. A (8-30-02) Page 1 of 2 |
XD010-24S |
|
|