QPP-010

 

60W, 925-960MHz

QuikPAC Module Data

Class AB Power Stage

General description:

The QPP-010 QuikPAC™ RF power module is a Class AB amplifier stage designed for use in the driver or output stage of linear RF power amplifiers for cellular base stations. The power transistors are fabricated using Xemod’s advanced design LDMOS process. This unit has a factory set, regulated and temperature compensated gate bias, eliminating the need for the user to provide adjustable gate bias voltage circuits and make individual bias adjustments during stage alignment.

Features:

Single Polarity Operation Matched for 50 Ω RF interfaces XeMOS FET Technology Stable Performance

QuikPAC System Compatible QuikClip or Flange Mounting

Standard Operating Conditions

Parameter

Symbol

Min

Nom

Max

Units

Frequency Range

F

925

 

960

MHz

Supply (Drain) Voltage

VD

26.0

28.0

32.0

VDC

Bias (Gate) Voltage

VG

11.0

12.0

13.0

VDC

Bias (Gate) Current, Average

IG

 

 

40

mA

RF Source & Load Impedance

Ω

 

50

 

Ohms

Load Impedance for Stable Operation (All Phases)

VSWR

 

 

10:1

 

 

 

 

 

 

 

Operating Baseplate Temperature

TOP

-20

 

+90

ºC

Output Device Thermal Resistance, Channel to Baseplate

Θjc

 

1.1

 

ºC/W

Maximum Ratings

Parameter

Symbol

Value

Units

Supply (Drain) Voltage

VDD

35

VDC

Control (Gate) Voltage, VDD = 0 VDC

VG

15

VDC

Input RF Power

PIN

5

W

Load Impedance for continuous operation without damage

VSWR

3:1

 

Output Device Channel Temperature

 

200

ºC

 

 

 

 

Lead temperature during reflow soldering

 

+210

ºC

Storage Temperature

TSTG

-40 to +100

ºC

Performance at 28VDC & 25ºC

Parameter

Symbol

Min

Nom

Max

Units

Supply (Drain) Voltage

VD1,2

27.8

28.0

28.2

VDC

Quiescent Current (total)

IDQ

540

600

660

mA

Power Output at 1 dB Compression (single tone)

P-1

60

70

 

W

Gain at 60W Power output (single tone)

G

15.0

16.5

 

dB

Gain Variation over frequency at 60W PEP (two tone)

G

 

0.4

0.5

dB

Input Return Loss (50 Ω Ref) AT 60W PEP (two tone)

IRL

11.0

17.5

 

dB

Drain Efficiency at 60W Pout (single tone)

η

40

45

 

%

Drain Efficiency at 60W PEP (two tone)

η

30

32

 

%

3rd Order IMD Product (2 tone at 60W PEP;1 MHz spacing)

 

 

-31

-27

dBc