XECOM XE1050, XE1040, XE1030, XE1080, XE1070, XE1060 Datasheet

Loading...

XE10X0

2/98

Single In-Line Telephone Line Interfaces for Europe

Description

Xecom's XE10X0 Single In-Line telephone interfaces offer complete, highly compact telephone interfaces for Europe, Japan and North America.

The XE10X0 family includes six models. Each meets the regulatory requirements for connection to the telephone network in one or more countries. A common single in-line package provides maximum flexibility in component placement and permits world-wide connectivity from one, simple circuit board layout.

XE1030 complies with the requirements of several European countries including the United Kingdom. It supplies 3750 volts isolation from the telephone line and has BABT, UL and CSA approval.

XE1040 provides the circuitry to connect to the German telephone network. It includes the 16 Khz Meter Tone Filter and 3750 volts isolation. The XE1040 also has BABT approval.

Features

*Small Size: 1.6" by 0.5" by 0.45";

*EN41003 Compliant;

*Ring Detection;

*Internal hookswitch;

*Single +5V Operation;

*3750 Volts RMS Isolation, 1500 Volts on XE1060;

*V.34.bis compatibility, 33.6 KBPS data transfer;

Models

*XE1030 for the UK;

*XE1040 for Germany;

*XE1050 for France;

*XE1060 for US, Canada, and Japan;

*XE1070 for Italy;

*XE1080 for Spain

XE10X0 Pin Configuration

XE1050 meets French telephone network

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

requirements. It includes BABT approval, over

 

 

 

 

 

 

 

 

 

 

Ring

 

 

1

 

current protection on both tip and ring, and

 

 

 

 

 

 

 

 

 

provides 3750 volt isolation.

 

 

 

 

 

 

 

 

 

XE1060 meets telecom requirements for North

 

Tip

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

America and Japan. It provides 1500 volts

 

 

 

 

 

 

 

 

 

isolation from the telephone network and is FCC

 

 

 

 

 

 

 

 

 

part 68 compliant.

 

OH

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

 

4

 

 

 

 

 

 

 

XE1070 provides a connection to the Italian

 

 

T1

 

5

 

 

 

 

 

 

 

 

 

telephone network. XE1070 includes BABT

 

 

T2

 

6

 

 

 

 

 

 

 

 

 

approval and provides 3750 volt isolation.

 

GND

 

7

 

 

 

 

 

 

 

 

 

 

RI

 

8

 

 

 

 

 

 

 

 

 

 

 

XE1080 connects to the Spanish telephone

 

VCC

 

9

 

 

 

 

 

 

 

network. XE1080 includes BABT approval and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

provides 3750 volt isolation.

 

 

 

 

 

 

 

 

 

XE10X0 Mechanical Specifications

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

Inches

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dim

Min

Max

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

0.420

0.460

10.80

11.56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

B

0.490

0.530

12.45

13.46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

0.120

0.140

3.05

3.56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

0.015

0.035

0.38

0.89

 

Pin 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

J

 

 

Pin 1

E

1.410

1.440

35.81

36.58

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

0.040

0.060

1.02

1.52

 

I

 

 

 

 

 

 

F

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

1.590

1.630

40.39

41.40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

1.070

1.080

27.18

27.43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

0.040

0.060

1.02

1.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

0.100

0.140

2.54

3.56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

0.300

0.340

7.62

8.64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin Size: 0.018" square

All pins tin-plated.

XE10X0 Block Diagram

 

 

 

 

Over-Current

 

 

 

 

Protection

 

 

 

 

(XE1050)

T1

 

Loop Current

 

TIP

 

Isolation

16 KHz

 

Holding

 

T2

Transformer

Circuit

Meter Tone

 

(All)

(All)

Filter

RING

 

(XE1040)

 

 

Low Impedance

 

MUTE

 

 

Pulse Dialing

 

 

(XE1040, XE1050, XE1070)

 

 

 

 

 

 

 

 

Hook-

OH

 

 

 

Switch

 

 

 

 

(All)

 

 

 

 

Ring

RI

 

 

 

Detect

 

 

 

(All)

 

 

 

 

XECOM

 

 

(2)

XE10X0

Pin Descriptions

PIN

NAME

DESCRIPTION

 

 

 

1

Ring

Ring provides one half of the two-wire connection to the telephone line. Ring

 

 

is isolated from all other circuitry. The XE1060 provides a 1500 Volt

 

 

isolation barrier; the remaining XE10X0 models provide a 3750 volt isolation

 

 

barrier. This isolation must be preserved throughout the system. This

 

 

isolation can be maintained by selecting properly rated components and

 

 

maintaining sufficient creepage and clearance distances.

 

 

 

2

Tip

Tip provides one half of the two-wire connection to the telephone line. Tip is

 

 

isolated from all other circuitry. The XE1060 provides a 1500 Volt isolation

 

 

barrier; the remaining XE10X0 models provide a 3750 volt isolation barrier.

 

 

This isolation must be preserved throughout the system. This isolation can

 

 

be maintained by selecting properly rated components and maintaining

 

 

sufficient creepage and clearance distances.

 

 

 

3

/OH

/OH is an active low input to the XE10X0 DAA module. It controls the internal

 

 

hookswitch. A low on OH closes the hookswitch and connects the

 

 

equipment to the telephone line.

 

 

 

4

/MUTE

This active low input provides low impedance pulse dialing in the XE1040,

 

 

XE1050, and XE1070. Presenting a low impedance to the telephone line

 

 

during pulse dialing is required in many European countries including

 

 

Germany, France and Italy.

 

 

 

5

T1

T1 provides half of the differential input/output connection to the secondary

 

 

side of the internal telephone line transformer.

 

 

 

6

T2

T2 provides half of the differential input/output connection to the secondary

 

 

side of the internal telephone line transformer.

 

 

 

7

GND

This pin provides ground reference for the RI, /OH and /Mute control lines.

 

 

There is no connection between ground and the telephone line (primary) side

 

 

of the XE10X0 DAA.

 

 

 

8

RI

Ring Indicate is an active high output from the DAA module. When a valid

 

 

ring signal appears on Tip and Ring, the DAA provides a pulse train at ring

 

 

frequency on RI.

 

 

 

9

VCC

This pin provides 5 volt DC power for the RI, /OH and /Mute control lines.

 

 

There is no connection between VCC and the telephone line (primary) side of

 

 

the XE10X0 DAA.

 

 

 

 

 

 

XECOM

(3)

XE10X0