Xantrex Technology 15, 20, 30, 10, 25 User Manual

4 (2)

Freedom Marine 10 15 20 25 30

Owner's Manual

Xantrex

Freedom Marine Series

Inverter/Charger

Thank you for purchasing a Xantrex Freedom Marine Series Inverter/Charger. Xantrex takes pride in manufacturing quality products specifically

designed to meet your power requirements.

Freedom Marine Inverter/Chargers provide silent, efficient and reliable AC power for a variety of applications. They feature “hands-free” operation, automatic three-stage battery charging and automatic AC transfer switching. For your convenience, service is available world-wide from qualified service centers.

If you have any questions about your Freedom Marine Inverter/Charger, please contact

Xantrex toll free: 1-800-670-0707.

For technical support and additional information about Xantrex products, visit our Web site at www.xantrex.com or e-mail us at CustomerService@xantrex.com

SAFETY SUMMARY

Safety information for installation and operation is contained throughout this manual where it applies and is not included in this summary.

Definitions:

Warning statements identify conditions or practices which could result in personal injury, loss of life, damage to equipment or other property.

Notice of Copyright

Fuse Replacement For continued protection against the possibility of fire, replace the fuse only with a fuse of the specified voltage, current and type ratings.

Power Source To avoid damage, operate the equipment only within the specified AC (line) and DC (battery) voltages.

Servicing To reduce the risk of electric shock do not open this unit. There are no user serviceable parts inside. Refer all service to qualified personnel.

Xantrex Freedom Marine Series Inverter/Charger © December 2002 Xantrex International. All rights reserved. Xantrex is a registered trademark of Xantrex International.

Disclaimer

UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”)

(a)MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.

(b)ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.

Date and Revision December 2002, Revision 2

Part Number 445-0194-01-01

Contact Information Web: www.xantrex.com

 

Email: CustomerService@xantrex.com

Phone: 1-800-670-0707 (toll free), 1-604-422-2777 (direct)

Fax: 1-604-420-2145

2

TABLE OF CONTENTS

Introduction. . . . . . . . . . . . . . . . . . . . . . . .

. 4

Installation Options . . . . . . . . . . . . . . . . .

.29

Things You Should Know

6

Shorepower Configurations

 

Inverter/Charger Configurations

 

Circuit Breaker Protection

 

 

 

Dual In/Dual Out Configuration

 

Thermostat Controlled Cooling

 

 

 

Installation Option 1

 

Inverter Idle Circuit

 

 

 

Installation Option 2

 

Low and High Battery Shutdown

 

 

 

Installation Option 3

 

Power Sharing

 

 

 

Installation Option 4

 

Temperature Sensitive Charging

 

 

 

 

 

Operation . . . . . . . . . . . . . . . . . . . . . . . . .

8

Installation Checks . . . . . . . . . . . . . . . . . .

.37

echo-charge . . . . . . . . . . . . . . . . . . . . . . . . .

10

Troubleshooting . . . . . . . . . . . . . . . . . . . . .

39

Optional Remote Control Panels

11

LED Fault Status

 

Things to Check

 

Batteries

12

 

Glossary

41

Battery Types

 

Battery Interconnection

 

Specifications . . . . . . . . . . . . . . . . . . . . . . . . .

43

Battery Bank Ratings and Sizing

 

Warranty

44

Battery Charging. . . . . . . . . . . . . . . . . . . .

16

Freedom Battery Chargers

 

 

 

Battery Charger Voltage Settings. . . . . . .

20

 

 

Installation Precautions . . . . . . . . . . . . . .

21

 

 

Installation . . . . . . . . . . . . . . . . . . . . . . . . .

22

 

 

Key Installation Points

 

 

 

Grounding

 

 

 

Neutral Bonding

 

 

 

AC Wiring

 

 

 

AC Input

AC Output

Ground Fault Circuit Interrupters

Remote Control Wiring

TSC Temperature Sensor

DC Wiring

Battery Cable Fusing

Hardware Stack-up Options

Specially designed for use in marine environment

3

INTRODUCTION

This owner’s manual describes the Freedom Marine Series Inverter/Chargers from Xantrex. These units perform four distinct functions:

1.DC to AC power inverting.

2.Automatic transfer switching between inverter power and incoming AC power.

3.Automatic three-stage battery charging plus manual battery equalizing.

4.Multiple battery bank charging.

• The inverter provides regulated 120 volt AC power at a crystal controlled frequency from a deep cycle battery bank and is rated at:

Freedom 10

1000 watts

Freedom 15

1500 watts

Freedom 20

2000 watts

Freedom 25

2500 watts

Freedom 30

3000 watts

The output is a modified sine wave and is compatible with most appliances, tools and other 120 VAC equipment. (Note: Certain laser printers, breadmakers, digital clocks and small battery chargers may not operate on modfied sine wave.) The idle mode reduces battery power consumption when AC loads are

removed from the inverter output. High efficiency ensures the longest possible battery life between charges. All models are designed to deliver surge current for starting loads larger than the continuous rating of the inverter.

• The internal transfer switch allows the Freedom Inverter/Charger to be connected to an external AC source and transfer the source power through the unit directly to the loads. When the external AC power source is disconnected, the transfer switch allows automatic switching of the loads back to the inverter.

The Freedom Inverter/Charger operates as a self-contained backup power system— just add batteries.

• Freedom battery chargers with temperature sensitive charging (TSC) are electronically controlled. The primary charge output current is rated at 12 volts:

Freedom 10

50

amps DC

Freedom 15

75

amps DC

Freedom 20

100 amps DC

Freedom 25

130 amps DC

Freedom 30

140 amps DC

They are designed to rapidly and optimally charge wet cell, gel cell, or Absorbed Glass Mat (AGM)** deep-cycle batteries. Battery charging is automatically accomplished in three stages: Bulk Charge, Acceptance Charge and Float Charge. In most cases, no attention or maintenance is required.

When using a Freedom or LINK remote control panel, a manually engaged Equalize Charge cycle is possible.

**Battery type selection is set on the front of the unit or with an optional remote (Remote Control Panel or Link Instrument).

4

INTRODUCTION

Multiple Battery Bank Charging

Multiple battery bank charging is provided through additional output from the built-in echocharge. The echo-charge is used to charge start or auxiliary batteries. This Digital echocharge is current limited to 15 amps and follows the three-stage charge curve of the inverter/charger and battery setting of the house battery bank. The number of active echo-charge outputs depends of the model of the inverter/charger.

Model

Multi-bank outputs

Freedom 10

1

Freedom 15

1

Freedom 20

1

Freedom 25

2

Freedom 30

2

 

 

echo-charge 1

echo-charge 2

Freedom Marine Inverter/Charger

5

THINGS YOU SHOULD KNOW

Circuit Breaker Protection

The Freedom Inverter/Charger is supplemental circuit breaker protected. The INVERT/CHARGE breaker on the front of the unit protects against sustained inverter/ charger over-current conditions.

This supplemental circuit breaker protects the output of the unit when operating in “Invert Mode” and protects the internal battery charger circuits when operating in “Charge Mode.” When an over-current condition occurs, the circuit breaker is reset by pushing the button back in after the fault is removed. This circuit breaker is not suitable for branch circuit protection. To comply with NEC, additional branch circuit rated breakers may be required between the output of the unit and the load.

Freedom 25 and 30 have two outputs. Both outputs are protected by the supplemental circuit breaker when operating in “Invert Mode.” During transfer/charge operation, the outputs are protected by the circuit breakers feeding the two inputs to the unit.

Thermostat Controlled Cooling

Freedom Inverter/Chargers are equipped with a thermostatically controlled fan that cools the unit so it can operate continually at its rated output.

KNOCKOUT

KNOCKOUT

 

AC OUTPUT

AC INPUT COMPRESSION TERMINAL

BLOCK installed

Inverter Idle Circuit

The idle circuit reduces battery power consumption when no AC load is present. Response from idle is instantaneous. When using a Freedom or Link remote control panel the idle threshold is adjustable. The unit does not produce 120 volts when in idle. An idle pulse is sent out approximately twice a second to see if a load is present. To bring the unit out of the idle condition, apply a load larger than the idle set point.

Low and High Battery Shutdown

When in inverter mode, if the battery voltage drops to 10.0 volts, the inverter will automatically shut off. Charge the batteries to 13.5 volts to automatically resume operation.

Voltage shutdown also occurs for a high battery condition at 15.5 volts. Operation will resume automatically when the battery voltage drops below 15.5 volts. Check all DC sources on the system for the reason for the excessive voltage.

Power Sharing

When connected to an external AC source the battery charger and transfer functions are engaged. A unique Power Sharing feature automatically reduces the AC power consumption of the battery charger when the loads threaten to trip the incoming circuit breaker.

Freedom 25 and 30 have two AC inputs. The battery charger is supplied AC from AC input #1. These models will reduce the current available to the charger when the demand for current to the load on AC output #1 reaches the factory default setting. AC input #2 is a direct transfer to AC output #2 and has no power sharing control.

6

THINGS YOU SHOULD KNOW

The Power Sharing set point of each unit has a factory default setting. This can be changed when using the Freedom or Link remote control panel. Refer to the Freedom Remote Control Panel or Link manual for information on Power Sharing setting and adjustment.

Temperature Sensitive Charging (TSC)

When the supplied battery temperature sensor is connected to the unit and the batteries, the charge voltage is controlled based on battery temperature. The charger adjusts the charge voltage to the best level insuring safe charging for selected battery type. Charge voltage regulation optimizes the battery life cycle.

Electronic Protection

Fast-acting electronic circuits protect the inverter from overloads and short circuits. Other protection includes a low and high battery voltage cutoff and automatic shutdown if an over temperature condition occurs. When the fault condition is corrected, the unit will automatically reset. For example: remove overload, charge batteries or allow to cool.

TSC Sensor

Battery

7

OPERATION

The Freedom Inverter/Charger provides 120 volt AC power from auxiliary DC batteries, automatic battery charging and automatic AC transfer switching between an external AC source and inverter mode AC output.

The Freedom Inverter/Charger may be operated with or without a remote control panel or Link instrument.

When operating the inverter/charger without a Freedom or Link remote control panel:

Front Panel Controls and Indicators

INVERT MODE

The INVERT push-button switch is located on the front of the unit.

• To turn the inverter ON, press and hold the INVERT switch until the INVERT LED is solid green. The unit is now inverting. Press the INVERT switch again to turn the inverter OFF. Note: The charge LED will be blinking slowly indicating Charger ready status but external AC power is not connected.

CHARGE MODE

The CHARGE push-button switch is located on the front of the unit.

When external AC is applied to the AC input of the unit, the charger automatically turns ON. The CHARGE LED will be solid green. The unit is now charging. Press the CHARGE switch again to turn the charger OFF. The charger defaults to ON when operating without a remote or with the Freedom Remote Control Panel. Refer to the Link manual when using a Link remote control panel.

INVERT

CHARGE

STATUS LEDs

Each Status LED performs two functions, providing operation status and battery type selection.

 

Status LEDs

 

Front Panel

INVERT CHARGE

REMOTE TSC

INVERT/WET

OVERTEMP

 

OVERLOAD / AGM

CHARGE / GEL1

LOW BATTERY / GEL 2

Operation Status

INVERT - Green LED

When the LED is solid green, the unit is in invert mode. This occurs by pressing the INVERT switch.

When the LED is blinking slowly (1 time per second), the inverter is in standby with AC power applied and the transfer switch engaged

When the LED is OFF, the inverter is

OFF.

CHARGE - Green LED

When the LED is solid green, the unit is in the charge mode and external AC power is being supplied.

When the LED is blinking slowly, (1 time per second) the charger is ready, but external AC power is not available.

When the LED is OFF, the charger has been manually turned OFF. This can only be accomplished while AC power is being supplied since the charger will automatically restart each time AC power is applied.

8

Freedom Marine 20

OPERATION

NOTE: When AC power is available, the default setting for the charger is ON. If the unit was manually turned OFF and AC power is interrupted and becomes available again, the charger will return to ON.

LOW BATTERY - Red LED

When the LED is OFF the battery voltage is normal, between 10.5 and 15.0 volts DC.

When the LED is solid red, it indicates a battery warning condition, the battery voltage is below 10.5 volts DC or above 15.0 volts DC.

When the LED is blinking slowly, (once per second), a battery shutdown has occurred. The voltage is either below 10.0 volts DC or above 15.5 volts DC.

When the LED is blinking rapidly (five times per second), a potential problem in the DC system has been detected. Check your batteries, battery cables and DC loads.

OVER-TEMP/OVERLOAD - Red LED

When the LED is Off operation is normal.

When the LED is red, there is an overtemp or overload condition. Check for excessive loads or short circuit on the output of the inverter. Correct the condition and restart by pushing the INVERT switch.

When the LED is blinking slowly (once per second), an over-current condition or a short circuit has occurred. The system has shut OFF and will not automatically restart. Correct the fault condition and manually restart the system by pushing the INVERT switch.

LOW BATTERY & OVER-TEMP/OVERLOAD

- Red LEDs

When both LEDs are blinking, an AC backfeed was detected. A backfeed occurs

when AC power from an external source is connected to the output of the inverter. Inspect wiring for a possible input/output wiring error. This condition must be corrected before further operation. A backfeed will damage the unit and void the warranty.

Battery Type Selection

• Battery type setup. To enter the battery type select mode, press and hold the INVERT switch for five seconds. The status LEDs will change from indicating status information to OFF. Press the CHARGE switch once. One of the four LEDs will blink rapidly, indicating the existing battery type selection.

Press the CHARGE switch again to change the battery type. Continue to press until the desired battery type is selected. If the CHARGE switch is not pressed for five seconds, the unit will return to normal operation and the battery type selection will have been made. Refer to page 20 for additional information on battery type settings.

WET GEL 1

GEL 2 AGM

Status LEDs

 

INVERT CHARGE

REMOTE TSC

INVERT/WET

OVERTEMP

 

OVERLOAD / AGM

CHARGE / GEL1

LOW BATTERY / GEL 2

Front Panel

When the 12 volt input to the unit is disconnected, the battery type setting is stored in non-volatile memory. When the unit is reconnected, the battery type selection conveniently returns to the previous setting.

If installed with the Freedom or Link remote control panel, the unit will be set up and controlled from the remote. Refer to the remote manual for more information.

9

OPERATION

When a Freedom or Link remote control panel is connected to the unit, the switch on the unit or on the remote may be used to turn the unit ON/OFF. If the unit is turned ON using the front panel switch and then turned OFF using a Remote or Link, the unit will not be completely OFF. If the unit will not be used for an extended period of time, turn the unit completely OFF. The unit is completely OFF when the LED display on the unit is OFF.

TSC (Temperature Sensitive Charging)

This provides for the connection of a sensor to measure battery temperature for compensated charging. If no sensor is connected the charge voltage levels are set to defaults based on battery type.

echo-charge

The echo-charge feature is incorporated in the Freedom Marine Inverter/Charger to enable multiple battery bank charging of the start or auxiliary battery. Freedom 10, 15, 20 have one active echo-charge output. Freedom 25, 30 have two active outputs.

The echo-charge automatically switches On/Off, charging an auxiliary or start battery without affecting the main house battery bank. The maximum charge current is 15 amps at

14.4volts.

The echo-charge is a voltage follower, fol-

lowing the three-stage charge modes of the Freedom Marine Charger. The echo-charge senses if the start battery needs charging and diverts a portion of the charging current (up to 15 amps) to the start battery. This method pro-

tects the auxiliary battery from overcharging and ensures a long life for the battery.

 

Over-temp

Low

Remote TSC

Battery

echo-charge

Freedom Marine 20

NOTE: The charger will always follow the house battery setting, even if you mix the type of batteries in your house and start battery bank. If the house battery bank is either GEL or AGM and the start or auxiliary battery is wet/ flooded, the charger will follow the GEL or AGM voltage setting.

The echo-charge will turn ON any time the house battery is above 13 volts, regardless of the charging source.

OPTIONAL REMOTES

If using one of the remotes, refer to the installation instructions included with the remote.

10

Xantrex Technology 15, 20, 30, 10, 25 User Manual

OPTIONAL REMOTE CONTROL PANELS

Remote Control Panel

An optional remote control panel is available. The LED bar graphs on the remote control panel show battery voltage and DC current in both inverter and charger modes.

Easy-to-see red, yellow and green LEDs show the battery state-of-charge. Power Sharing, charger ON/OFF, and inverter ON/ OFF controls are provided. SET UP features include selection of Idle Threshold, Battery Type and Battery Capacity.

LINK 2000

The Link 2000 has the same features as the Link 1000, providing inverter/charger control and complete battery state-of-charge information. It monitors two battery banks.

LINK 2000

Remote Control Panel

Advanced Remote Control Panels Link Instruments

Advanced remote control panels are also available: the Link 1000, 2000 and 2000-R.

LINK 1000

Link 1000 controls the Freedom Inverter/ Charger and provides complete battery state-of-charge information including DC voltage, current, amp hours consumed, Time Remaining and historical data for a single battery bank.

LINK 2000-R

The Link 2000-R adds the ability to regulate an engine-driven alternator. The precision regulator in the Link 2000-R allows the alternator to be controlled as a three-stage battery charging system.

If a Link Instrument is used to control the inverter/charger, refer to the Link Owner’s Manual for installation, setup and control information.

LINK 1000

11

BATTERIES

BATTERY TYPES

Use only deep-cycle batteries with your Freedom Inverter/Charger. These fall into three broad categories: wet cell, gel cell and Advanced AGM (Absorbed Glass Mat) batteries.

Wet Cell Batteries

True deep-cycle wet cell batteries are characterized by relatively thick internal plates that are alloyed with antimony.

Common 12 volt marine/RV deep-cycle batteries are acceptable. Golf cart batteries perform well and may have a longer life. These 6 volt batteries must be used in series connected pairs. High quality deep-cycle batteries offer good performance and are available in a wide variety of sizes.

Wet cell batteries will give off gas as a natural result of charging and will experience some water loss. It is very important that the electrolyte level be checked frequently and topped off with distilled water when necessary. Follow the battery manufacturer’s recommendations for maintenance.

Never allow the top of the battery plates to be exposed to air, as contamination of the cell will result. Keep the tops of batteries clean.

Always provide adequate ventilation for the battery storage compartment.

Do not use ordinary car batteries or engine starting batteries with your inverter/ charger. Beware of any battery that is rated only in Cold Cranking Amps (CCA). This is a rating which applies only to engine starting batteries. In general, most wet cell batteries that are described as hybrid type batteries, suitable for either engine starting or deep-cycle applications, are a compromise and will have limited life if deeply discharged.

12

BATTERIES

Beware of so-called maintenance-free wet cell batteries. These batteries have calcium alloyed with the lead liquid. They are sealed and water cannot be added. Do not confuse them with true gel cell or AGM batteries—they will not hold up well to deep discharging and repeated cycling.

Gel Cell Batteries

Gel cell batteries are lead-acid batteries similar in many ways to the common wet cell battery, but differences in the chemistry and construction provide some unique features.

No Maintenance

Low Self-Discharge Rate

Low Internal Resistance

Even though gel cells are sealed batteries, the battery compartment should still be ventilated.

Advanced AGM (Absorbed Glass Mat) Batteries

This battery is lead acid but maintenance free. They hold the liquid electrolyte in a sponge-like material. The performance is similar to gel cell batteries. The charge parameters are similar to wet cell batteries.

Battery Selection

The most important feature to consider in making your battery selection is to select true deep cycle batteries rated in amp hours (Ah) and sized to match your power requirements.

BATTERY INTERCONNECTION

In most cases, you will be using a bank of two or more batteries with your inverter/charger. You may connect batteries together in two configurations—series and parallel— depending on their voltage.

Series Configuration

Connecting two batteries in series will double the voltage of the battery bank. For instance, two 6 volt batteries connected in series will produce 12 volts. The amp-hour capacity of the battery bank will be the same as each individual battery. Example, two 6 volt 220 amp-hour batteries in series will produce one 12 volt 220 amp-hour battery bank.

++

Series

Series Increase Voltage

+

+

+

6V

6V

12V INVERTER

_

_

_

 

 

EACH BATTERY

 

TOTAL BATTERY

CAPACITY:

 

BANK CAPACITY:

220

 

220

AMP HOURS

 

AMP HOURS

@ 6 VDC

 

@ 12 VDC

13

BATTERIES

Parallel Configuration

Connecting two batteries in parallel will double the amp-hour rating of the battery bank, while the voltage will be the same as each individual battery. Example, two 12 volt 105 amp-hour batteries in parallel will produce one 12 volt 210 amp-hour battery bank.

+

+

Parallel

Parallel Increase Amp-hour Capacity

+

+

+

12V

12V

12VINVERTER

_

_

_

 

 

EACH BATTERY

 

TOTAL BATTERY

CAPACITY:

 

BANK CAPACITY:

105

 

210

AMP HOURS

 

AMP HOURS

@ 12 VDC

 

@ 12 VDC

Only similar batteries should be connected together in one bank. Do not connect old and new batteries together or wet and gel cell batteries together. In the above drawing, the load is connected to the positive terminal of the first battery and the negative terminal of the last battery. This practice helps to balance the battery bank and is called cross-connecting the battery bank.

Note: It is not advisable to connect batteries of different case sizes or amp-hour ratings in the same battery bank.

Always use properly sized wire and terminals for your interconnecting battery cables. For size information refer to NEC requirements or contact your local electrician.

BATTERY BANK RATINGS AND SIZING

Deep-cycle batteries are usually rated in amp hours. The amp-hour rating is based on a 20-hour discharge rate, therefore, a 100 amp-hour battery can deliver 5 amps for 20 hours. If the discharge rate is greater than 5 amps, the available amp hours are decreased. For example, if the load is increased to 100 amps, only about 45 amp hours will be available at this rate of discharge.

Deep-cycle batteries can be discharged about 80% of capacity before damage occurs. Shallow cycling will result in much longer battery life. Calculating a battery bank size based on 50% discharge cycling is generally considered to be a good compromise between long battery life and size.

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To achieve 50% cycling you should

 

 

 

 

AMP-HOUR CONSUMPTION FORMULAS

calculate your amp-hour consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(AC amps x 10) x 1.1 x hours of

 

between charging cycles and use a battery

 

 

 

 

bank with twice that capacity**. Each AC

 

 

 

 

 

operation = DC amp hours

 

appliance or tool has a rating plate on it and will

 

 

 

(watts/ DC voltage) x 1.1 x hours of

 

be rated in either AC amps or watts or AC VA

 

 

 

 

 

 

 

operation = DC amp hours

 

(volt-amps) apparent power. To calculate amp-

 

 

 

 

 

 

 

(AC VA/ DC voltage) x 1.1 x hours of

 

hour consumption, use one of the formulas to

 

 

 

 

the right to calculate the DC amp-hour draw for

 

 

 

operation = DC amp hours

 

a 12 volt system.

 

 

 

 

 

 

 

 

 

 

 

DC voltage is 12, 24 or 32 depending on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculate the amp hours for every AC

 

 

 

 

 

 

 

 

your system.

 

appliance or tool that will be operated on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

inverter. This will provide the total number of

 

 

In all formulas, 1.1 is the correction factor for

amp hours used between recharges. Size the

 

 

 

 

 

 

inverter efficiency.

battery bank using this number as a guideline.

 

Typical Power Consumptlon

A good rule to follow is to size the battery bank

 

a minimum of two times larger than the

 

 

 

 

 

The chart identifies typical power

total amp-hour load requirement. Plan on

 

 

 

consumption for common AC loads. Use it as

recharging when 50% discharged.

 

 

 

 

 

a guide when identifying your power

**Batteries are typically charged to 85% of full

 

requirements.

 

 

 

 

 

 

 

 

Many electric motors have

charge when charging with alternators without 3-stage

 

 

 

 

 

 

regulators.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

momentary starting requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

well above their operational rating.

 

Typical Power Consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start up watts are listed where

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance

Typical

 

 

Appliance Run Times / Amp Hours

 

 

 

 

appropriate. Individual styles and

Wattage

 

 

 

 

 

 

 

 

 

 

 

 

 

brands of appliances may vary.

 

5 Min.

15 Min.

30 Min.

 

1 Hr.

 

2 Hr.

 

3 Hr.

 

8 Hr.

24 Hr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If using the same battery

13" Color TV

50

.33

1

2

 

4

 

8

 

12

 

 

32

96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bank for the inverter and other

19" Color TV

100

.66

2

4

 

8

 

16

 

24

 

 

64

192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC loads, be sure to consider

VCR

50

.33

1

2

 

4

 

8

 

12

 

 

32

96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the power consumption of the

Lamp

100

.66

2

4

 

8

 

16

 

24

 

 

64

192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC loads when sizing the

Blender

300

2

6

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

battery bank.

Laptop Computer

50

.33

1

2

 

4

 

8

 

 

 

 

 

 

 

Curling Iron

50

.33

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8 Power Drill

500

3.3

10

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Icemaker*

200

 

 

2.6

 

5.2

 

10.4

 

15.6

 

41.6

83.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coffee Maker

1000

6.6

20

40

 

80

 

160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 cu' Refrigerator*

150

 

 

2

 

4

 

8

 

12

 

 

32

96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 cu' Refrigerator*

750

 

 

21

 

42

 

84

 

126

 

336

672

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compact Microwave

750

5

15

30

 

60

 

120

 

180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full Size Microwave

1500

10

30

60

 

120

 

240

 

360

 

 

 

 

NOTE Certain laser printers, breadmakers,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum

1100

7.3

22

44

 

88

 

176

 

264

 

 

 

 

digital clocks and appliance/tool chargers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number in each box represents the total Amp hours used (@ 12 volt DC) based on various continuous run times. *Note refrigeration is typically calculated using a 1/3-duty cyle.

may not operate on modified sine wave.

15

Loading...