Xantrex SWCA Owner's Manual

Page 1
Owner’s Manual
SW Communications Adapter (SWCA)
Page 2
ii
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Xantrex Technology Inc., is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to 1 MW utility­scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power.
Trademarks
Trace and Xantrex are registered trademarks of Xantrex International.
Notice of Copyright
SW Communications Adapter (SWCA) Owner’s Manual © April 2002 Xantrex Technology Inc. All rights reserved.
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents of this guide, Xantrex International assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.
Since the use of this manual and the conditions or methods of installation, operation, use and maintenance of the unit are beyond the control of Xantrex Technology Inc., the company does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of or any way connected with such installation, operation, use, or maintenance.
Due to continual improvement through product updates, photographs and/or illustrations used in this manual may not
exactly
match your unit. Xantrex Technology Inc., reserves the right to update this product without notice or releasing an updated manual when
fit, form or function
are not affected.
Date and Revision
April 2002, Revision A
Part Number
973-0022-01-01
Contact Information
Web: www.xantrex.com
Email: dpm@xantrex.com
Phone: 360.435.8826
Fax: 360.435.2229
Page 3
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
iii
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions that should be followed
during the installation and maintenance of this product.
To reduce the risk of electrical shock, and to ensure the safe installation and operation of this product, the following safety symbols have been placed throughout this manual to indicate dangerous conditions and important safety instructions.
WARNING
- A DANGEROUS VOLTAGE OR CONDITION EXISTS IN THIS AREA. USE EXTREME CAUTION WHEN PERFORMING THESE TASKS.
AVERTISSEMENT
- UNE TENSION OU CONDITION DANGEREUSE EXISTE DANS CETTE ZONE. FAIRE PREUVE D’EXTRÊME PRUDENCE LORS DE LA RÉALISATION DE CES TÂCHES.
CAUTION
- This procedure is critical to the safe installation or operation of the unit. Follow these instructions closely.
ATTENTION
- Cette procédure est essentielle à l’installation ou l’utilisation de l’unité en toute sécurité. Suivre ces instructions de près.
NOTE
- This statement is important. Follow instructions
closely.
NOTE
- Cette déclaration est importante. Suivre les
instructions de près.
• All electrical work must be done in accordance with local, national, and/or international electrical codes.
• Before installing or using this device, read all instructions and cautionary markings located in the manual, and on the inverter, the batteries, and the PV array.
• Do not expose this unit to rain, snow or liquids of any type. This product is designed only for indoor usage.
• This product contains no user-serviceable parts. Do not attempt to repair this unit.
Page 4
iv
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Table of Contents
IMPORTANT SAFETY INSTRUCTIONS ........................................................... iii
1.0 INTRODUCTION ............................................................... 1
2.0 INSTALLATION .................................................................. 3
To install the SWCA ........................................................................................... 3
Connecting the SWCA to a Computer using a Modem ............................ 4
Requirements ............................................................................................. 4
Additional Possible Requirements .......................................................... 4
Connecting Multiple SWCAs to a Single Computer .................................. 4
Advanced Monitoring Software .................................................................... 5
Installation Concerns ......................................................................................... 5
Multiple SWCAs ............................................................................................. 5
Positive Ground or PV Ground Fault Protection Installations .................. 5
Installing the SWCPS DOS Program ................................................................ 8
3.0 OPERA TION ....................................................................... 9
Using the SWCPS DOS Program ..................................................................... 9
SWCA DOS Display Emulation Software .................................................... 9
Virtual Control Panel ................................................................................. 9
Function Keys and Other Displays .............................................................. 10
The SWCA Programming Menu ............................................................ 10
The SWCA Programming Menu Function Keys .................................... 11
LED Control Indicators ........................................................................... 12
Keyboard Commands .............................................................................. 13
Starting the Program ................................................................................... 14
ID Numbers .................................................................................................. 14
Changing the PC’s COM Port Number ..................................................... 14
Accessing HELP Information from the SWCPS Program ........................ 15
Accessing the SETUP MENU from the SWCPS Program ....................... 15
Switching Between Multiple SWCA Adapters/inverters .......................... 15
Exiting the SWCPS Program ....................................................................... 15
Use of the SWCA with Terminal Emulation Programs ................................. 16
Making a New Connection .......................................................................... 16
Telephone Number ...................................................................................... 17
COM Port Values .......................................................................................... 18
Testing the SWCA ............................................................................................. 19
4.0 TROUBLESHOOTING ...................................................... 21
Page 5
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
v
APPENDIX A PRODUCT AND SYSTEM INFORMA TION......A-1
Warranty ............................................................................................................ A-1
Return Material Authorization Policy ............................................................A-2
Return Material Procedure .............................................................................. A-2
Service Information ......................................................................................... A-3
Table of Contents
(continued)
Page 6
vi
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
List of Figures
Figure 1-1 SW Communications Adapter (SWCA) .................................1
Figure 2-1 SW Inverter/Charger Remote Port Location .......................... 3
Figure 2-2 SWCAs in Multiple-Inverter Installations ............................. 6
Figure 2-2a Enlargement of Pin Assignments and Color Coding
on Custom-made Serial Port Adapter ............................... 7
Figure 2-2b Enlargement of Pin Assignments and Color Coding
for 25-foot (4-conductor, telephone standard) Cable ..... 7
Figure 2-2c Enlargement of Pin Assignments and Color Coding
on SWCA Adapter ............................................................... 7
Figure 3-1 Virtual Display using DOS Emulation Program ................... 9
Figure 3-2 SWCA Programming Menu Display.................................... 10
Figure 3-3 Making a New Connection ................................................... 16
Figure 3-4 Telephone Number Dialog Box ............................................ 17
Figure 3-5 Com 1 Properties ................................................................... 18
Page 7
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
vii
List of Tables
Table 3-1 The SWCA Programming Menu ...........................................11
Table 3-2 LED Control Indicator Definitions ....................................... 12
Table 3-3 Keyboard Commands for using Terminal
Emulation Programs ......................................................... 14
Table 4-1 Troubleshooting the SWCA .................................................. 21
Page 8
viii
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Page 9
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
1
1.0 INTRODUCTION
The Sine Wave Communications Adapter (SWCA) allows any SW series inverter/charger to be connected to a computer serial port or directly to a modem to be controlled and monitored over long distances.
The SWCA package includes the following items:
• SWCA adapter (gray plastic housing with green LED, phone jack and a 25-pin connector)
• Custom-made Serial Port Adapter (black plastic housing with phone jack and 9-pin connector)
• 25-foot, 4-conductor phone cable (with RJ11 jack tabs on the same side of the cable)
• 3.5" floppy disk with DOS program SWCPS.EXE (simulates the inverters control panel)
• SWCA Owner’s Manual
Please be sure all of these parts are included before trying to use the SWCA.
Figure 1-1
SW Communications Adapter (SWCA)
Phone Cable
Custom-Made
Serial Port Adapter
SWCA
Adapter
Page 10
2
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Page 11
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
3
2.0 INSTALLATION
The SWCA converts the REMOTE port on the SW series inverter/charger into a
standard RS232 type communications port interface.
See Figure 2-1 for the location of the REMOTE PORT on the SW inverter/ charger.
TO INSTALL THE SWCA
1. Connect the SWCA adapter to the SW series inverter/charger
remote
port
located on the left end of the inverter, near the AC wiring compartment.
NOTE: There are two ports located on the inverter – one
is used for the stacking cable and the other is for the remote control port. Make sure you connect the SWCA to the correct port. If a SW series remote control is being used, it will have to be disconnected while the SWCA is in use.
2. Connect the phone cable to the phone jack on the gray SWCA housing and to the black serial port adapter.
3. Plug the serial port adapter into the computer serial port.
NOTE: On some computers, a DB9-to-DB25 adapter may be needed to allow connection.
Figure 2-1
SW Inverter/Charger Remote Port Location
NOTE: The location of the REMOTE PORT may vary slightly depending upon the model of SW inverter/charger being used. All models should be labeled, however, to simplify the identification and location of the port.
Remote
Port
Page 12
2.0 INSTALLATION
4
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Connecting the SWCA to a Computer using a Modem
The SWCA can be connected directly to a modem for use in remote sites
where a computer may not be available.
Requirements
To use a modem, the following is required:
• a terminal emulation program,
See
SECTION 3.0 OPERATION, Use of the SWCA with Terminal
Emulation Programs
.
• a modem capable of auto answer and supporting a 9600 baud connection,
• an adapter for the DB9 connection from the phone cable to serial port adapter,
•a
NULL MODEM
adapter will be required for most applications. Contact the
modem provider and modem documentation for more information.
Additional Possible Requirements
The modem at the inverter location might need to be DC powered if it is necessary to connect to the inverter during a fault condition where the inverter has shut off its AC output.
Connecting Multiple SWCAs to a Single Computer
Up to eight SWCAs can be used with a single computer serial port. The phone cable four conductors are simply run in parallel using standard phone cable line “splitters”. The splitters must connect the wires of the same color together – do not switch the colors around.
Before connecting multiple adapters to a serial port, connect each adapter individually to ensure it operates properly. The adapter ID number must be changed by using the DOS program provided on the disk before they are connected to the same computer serial port. The ID number can only be changed with a single adapter connected to the computer’s serial port.
Page 13
2.0 INSTALLATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
5
Advanced Monitoring Software
The SWCA was developed to change the SW inverter raw data output to an RS232 protocol output. The SWCA code only manipulates the inverter’s display or remote (SWRC) keypad strokes. The included DOS software emulates these keystrokes.
There are companies that have used these keystroke’s bits of information (coming out of the SWCA) to develop advanced monitoring software. This software can provide monitoring and data logging capability. Additional information on these programs can be found at www.righthandeng.com or www.mauisolarsoftware.com.
NOTE: Xantrex Technology Inc. assumes no responsibility for the use or function of these advanced monitoring software programs.
INSTALLATION CONCERNS
Multiple SWCAs
If using multiple SWCAs and multiple inverters, the green wire must be isolated from each other as shown in Figure 2-2 on page 6.
NOTE: This could be a red wire - depending on the cable installation from the SWCA).
Positive Ground or PV Ground Fault Protection Installations
When using the SWCA in inverter installations that have DC ground fault protection (PVGFP) or where the inverter is connected in a “positive ground” configuration, it is recommended that an opto-isolator be connected somewhere between the SWCA and the computer com port. Opto-isolators can be obtained through www.blackbox.com (part SP400A-R3 and PS576 - 9Vdc power supply).
Page 14
2.0 INSTALLATION
6
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Installation Concerns (continued)
Figure 2-2
SWCAs in Multiple-Inverter Installations
Page 15
2.0 INSTALLATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
7
Figure 2-2a
Enlargement of Pin Assignments and Color Coding
on Custom-made Serial Port Adapter
5 4 3 2 1
6
BLACK (YELLOW*) RED (GREEN*) GREEN (RED*) YELLOW (BLACK*)
*Depending on the Cable Installation
Figure 2-2b Enlargement of Pin Assignments and Color Coding for 25-foot (4-conductor, telephone standard) Cable
%/$&.<(//2:
5('*5((1
*5((15('
<(//2:%/$&.
'HSHQGLQJRQ W KH&DEOH ,QVWDOODW LRQ
%/$&.<(//2:
5('*5((1
*5((15('
<(//2:%/$&.
'HSHQGLQJRQWKH&DEOH,QVWDOODWLRQ
Figure 2-2c
Enlargement of Pin Assignments and Color Coding on SWCA Adapter
Page 16
2.0 INSTALLATION
8
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
INSTALLING THE SWCPS DOS PROGRAM
A control panel simulation software program included on the floppy disk allows an IBM-compatible personal computer to operate as a virtual control panel for up to eight SW series inverter/chargers.
For other computer platforms, See
SECTION 3.0 OPERATION, Use of the
SWCA with Terminal Emulation Programs
, on page 9.
To install the software, insert the floppy disk into your computer floppy drive and copy the file
swcps.exe
from the floppy disk provided to the hard disk on the computer. Remember the location of this file on the hard disk for later reference. Alternately, the program can be run directly from the floppy disk.
Page 17
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
9
3.0 OPERATION
USING THE SWCPS DOS PROGRAM
This section describes the operation of the SWCPS DOS program.
SWCA DOS Display Emulation Software
Virtual Control Panel
6HW,QYHUWHU 2))65&+21&+*
$&*22'
)/2$7
$'$37(5
&203257
0(18,7(0
))
7UDFH6:6HULHV)URQW3DQHO6LPXODWRU'269HUVLRQ
6(732,176
))
0(18+($',1*6
))
*(1
)
212))
)
F 75$&((1*, 1( (5 ,1 *,1&$UOL QJ WR Q : $86$
Figure 3-1
Virtual Display using DOS emulation program
The DOS software program allows an IBM compatible personal computer to operate as a virtual control panel for up to eight SW series inverter/chargers. As shown in Figure 3-1, the function keys on the computer are the key to operating the inverter using the software. They act as the up and down arrow keys for each different function of the inverter just as the up and down arrow keys do on the inverter. The screen graphically displays which keys perform which functions.
Since the display mimics the inverter, operation is very easy for anyone already familiar with the SW series controls.
NOTE: If the adapter is plugged into the inverter after the inverter is already on, the computer “LCD” display may be blank until a key is pressed on the computer or the inverter itself. The textual LED indicators on the computer will work normally. If you are new to the SW series inverters, reading the owner’s manual in full will ensure getting the most from the system.
To the right of the “LCD” display is a representation of the inverter’s LED (lighted) status indicators. All status functions shown by the inverter’s LED’s are displayed on the screen. The only difference is that the computerized display does not show the status lights – it shows words that represent each function. When an LED status light on each unit is flashing, the word or words on the computer version will flash also.
Page 18
3.0 OPERATION
10
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Function Keys and Other Displays
On the virtual control panel simulation, the buttons of the real control panel have been replaced with labels shown as F1 through F10. These refer to the function keys of the computer keyboard which are located either above or next to the main keyboard area. Each function key is associated with a specific inverter operation. Pressing the appropriate function key causes the display on both the inverter and the PC screen to change accordingly.
The virtual control panel also shows the LCD display window on the inverter’s control panel. This will show the same information that is available at the inverter. When no adapter is available, the text “ADAPTER OFFLINE” appears. When an SWCA has been successfully connected, the LCD display window of the control panel simulator shows what is displayed on the inverter LCD display (e.g., adapter 3).
To the right of the LCD display area on the control panel simulator is an area where the status of the inverter’s LED indicators are displayed. Any active LEDs are displayed by the label description of the LEDs function being shown. If the LED is flashing on the inverter, then the label description of the LED will also flash on the control panel simulator.
Since the same menu system is used with the control panel simulator as with the inverter itself, the operation of the SWCA will be familiar to anyone who has programmed a SW series inverter/charger system. The only difference is the use of the function keys instead of the buttons.
The SWCA Programming Menu
The SWCA Programming Menu provides the means to change the SWCA ID number or for changing the adapter’s configuration code. It also provides the means for applying a textual identification labels.
Below the “LCD” display on the computer version, the word “ADAPTER” appears. This shows which inverter is being accesssed. To access the different inverters, simply enter the ID number of the inverter (1-8) that you want to control by using the computer’s numeric keys.
$GDSWHU,'1XPEHU
&RQILJXUDWLRQ$ &RQILJXUDWLRQ% 6HULDO1XPEHU 6RIWZDUH,'6:&$9HU  &XVWRPHU,'
6LQH:DYH&RPPXQLFDWLRQV0HPRU\$GDSWHU352*5$00,1*0(18
3UHVV(6&!WRUHWXUQWR6:)URQW3DQHO6LPXODWLRQ
)! 1HZ$GDSWHU,'
)! 1HZ&RQILJXUDWLRQ )! 1HZ&XVWRPHU,'
67$7862.
Figure 3-2
SWCA Programming Menu Display
Page 19
3.0 OPERATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
11
NOTE: If the program does not find an adapter it indicates a
TIMEOUT ERROR
. Check the adapter and
cable for proper connection and retry the program.
The SWCA Programming Menu Function Keys
Programming features are accessed by pressing
ALT+P
and by using the
function keys as described in Table 3-1.
Table 3-1
The SWCA Programming Menu
yeK esopruP
1F
1fotluafedehtmorfrebmunDIACWSsegnahC
.8otpurebmunynaot
sretpadaehtetirw,rebmunDIehtgnignahcretfA s'retpadaehtfoedistuoehtnorebmunDIwen ehtfonoitacifitnediretalekamotgnisuohyarg
.reisaeretpada
2F
sihT.edocnoitarugifnocs'retpadaehtsegnahC
.retpadaehtfonoitarepoehtsretla
tluafedehtmorfedocsihtegnahctonoD
."60"foeulav
3F
retalwollaotgnirtstxetynanignipytroF
.retpadaehtfonoitacifitnedi
.>retnE<sserpdnanoitamrofniderisedniepyT
SCE
.unemgnimmargorpehtsevaeL
Page 20
3.0 OPERATION
12
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
LED Control Indicators
The codes indicate the status of the inverter’s LEDs. The two letter codes are
as follows:
noitaiverbbA noitinifeD
NIgnitrevnI
TLeiTeniL
1ANI1CA
2ANI2CA
KBkluB
LFtaolF
RErorrE
COtnerruCrevO
Table 3-2
LED Control Indicator Definitions
If no codes display, it is because there are no LEDs on or the adapter is not
responding.
NOTE: If an LED is flashing, it may not appear each time you pressed “1” because it was not illuminated when the SWCA sent the data to the computer. A flashing o LED should be indicated by the LED two letter code being repeated on the display.
Page 21
3.0 OPERATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
13
Keyboard Commands
The following keystrokes enable navigation through the menus and provide
the means to change available settings.
ekortsyeK noitcnuF
8-1
:retrevnitceleS
.tluafedehtsi1.rebmunDIs'retrevniehtsi8hguorht1
L–sgnidaeHuneM
R+sgnidaeHuneM
U)potsdrawot(emtIuneM
D)mottobsdrawot(+emtIuneM
_ro-)eulavrewol(tnioPteS
=ro+)eulavrehgih(+tnioPteS
I
uneMFFO/nOretrevnI
)lenaplortnocretrevniehtnonottubDERehtsaemas(
G
uneMFFO/nOrotareneG
lortnocretrevniehtnonottubNEERGehtsaemas(
)lenap
>S<>lrtC<
uneMputeS
ehttauneMFFO/nOdnarotareneGgnihsupsaemas(
)emitemas
/ro?sutatSDEL
VACWSforebmunnoisreV
T
edomlanimretteS
gniyrt,yalpsidsretcarahcegnartsfostoleesuoyfI
.edomlanimretrof"T"gnisserp
Table 3-3
Keyboard Commands for using Terminal Emulation Programs
Page 22
3.0 OPERATION
14
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Starting the Program
From Windows:
1. Open
MY COMPUTER
or
WINDOWS EXPLORER
.
2. Locate the file
swcps.exe
and double-click it.
or
1. Click
START
.
2. Select
RUN
.
3. Type
swcps
and press <
Enter
>.
From DOS (or a DOS prompt within Windows):
1. Locate the file
swcps.exe
.
2. Type
swcps
and press <
Enter
>.
When the program starts, a line drawing of the SW series control panel will appear on the computer screen. You can resize the MSDOS window for better viewing of the control panel if the labeling is not clear.
ID Numbers
Once the program has started, it looks for an SWCA programmed with an ID number of “1”. This is the default ID number of all adapters. If two adapters are connected to a PC with the same ID number, you will not be able to communicate with either until the adapters have different ID numbers.
Refer to Table 3-1 on page 11 for information on accessing the SWCA Programming Menu to reprogram the adapters with a different ID number.
The program also assumes that the SWCA is connected to a serial port with a COM number of 1. If you are using a COM port other than one, refer to the paragraph in this section titled
Changing the PC’s COM Port Number
.
Changing the PC’s COM Port Number
To change the COM port number that the control panel simulator DOS program uses to find the adapter, add the COM port ID number (1-4) after the DOS command used to start the SWCPS program as follows:
C:> SWCPS 2
This command causes the program to look at the COM 2 port on the PC for the SWCA adapters.
Page 23
3.0 OPERATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
15
Accessing HELP Information from the SWCPS Program
Help is available while using the SWCPS program by pressing F10 on the
computer keyboard.
To leave the help screen, press the
ESC
key to return to control panel
simulation program.
Accessing the SETUP MENU from the SWCPS Program
To access the inverter
SETUP MENU
, press ALT-F8 together. This feature is
available for inverters with Rev 4.01 and higher software versions.
To leave the
SETUP MENU
, press F7 which returns you to the
SET INVERTER
main menu display.
Switching Between Multiple SWCA Adapters/inverters
To select another inverter, simply press the number key for the SWCA adapter that was programmed in and written on the outside of the adapter as previously discussed. Use numbers from 1 to 8.
Exiting the SWCPS Program
To exit the SWCPS program, press ALT-X. You can also use the ESC key to quit as well.
Page 24
3.0 OPERATION
16
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
USE OF THE SWCA WITH TERMINAL EMULATION PROGRAMS
Modem connection requires the use of a terminal emulation program as described in the following sections. A modem is required at both the inverters and at the computer, with a phone line available to make the connection.
The SW Communications Adapter (SWCA) supports use with “terminal emulation” programs. Any computer that has available serial communications port and terminal emulation software can communicate with the SW series inverter using a cable and modem connection.
Making a New Connection
1. Start the terminal emulation software of your choice.
2. Enter “SWCA” in the Name location.
3. Select the desired icon.
4. Click “OK”.
Figure 3-3
Making a New Connection
Page 25
3.0 OPERATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
17
Establishing the Connection
1. Enter Country code: (e.g., United States of America (1))
2. Enter Area code: (e.g., 360)
3. Enter Phone Number: (e.g., 435-8826)
4. For connections to the SWCA with a cable, select “Direct to COM1”. (If you are using a port other than COM1, choose the com port you are using.)
5. For connections to the SWCA with a modem, select “xxx Bps Data Fax Modem” (where “xxx” is the transmission speed of the modem being used.
6. Click OK.
Figure 3-4
Telephone Number Dialog Box
Use of the SWCA with Terminal Emulation Programs (continued)
Page 26
3.0 OPERATION
18
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
COM Port Values
You need to enter the following values for the COM port as shown in
Figure 3-5.
Bits per second: 9600 BAUD
Data bits: 8
Parity: No or None
Stop Bits: 1
Flow control: Either setting
NOTE: These are the only acceptable values
Figure 3-5
COM1 Properties
Click OK and a blank window opens.
Page 27
3.0 OPERATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
19
TESTING THE SWCA
In order to test the SWCA, it must be plugged it into an inverter that is powered up on batteries or a suitable power supply. Press the number “1”. If everything is correct, the inverter should reply with a “UNIT1” and possibly some two character codes.
Page 28
3.0 OPERATION
20
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Page 29
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
21
4.0 TROUBLESHOOTING
motpmyS noitadnemmoceR
:sdaeryalpsiD
ENILFFORETPADA
nehwdeyalpsidsisihT
yalpsidSODehtgninnur
nehwmargorpnoitalume
retpadaonsiereht
.esnopser
otgniyrterauoyretpadaehtforebmunDIehtkcehC.1
erehtnehwyalpsidlliwsihT.tcerrocsitierusnE.ssecca
.gniretneerauoyrebmunDIehthtiwretpadaonsi
etomerehtotretpadaehtmorfnoitcennocehtkcehC.2
.trop
ehtottroPMOCehtmorfnoitcennocehtkcehC.3
.tropetomer
.retpadAACWSehtnoDELehtkcehC.4
s'retrevniehtotdetcennocnehwsetanimullitifI.a
.dezingocersiretpadaehtneht,tropetomer
ehtotdetcennocnehwetanimullitonseodtifI.b
siretpadaehtneht,tropetomers'retrevni
.decalperebotsdeendnagninoitcnuflam
tonsi)medomaiv(ataD
.elbazingocer
pu-laidehtdnamedomehtrofetarDUABehterusnE
.0069tadexifsimargorp
gnitcennoctonsimedoM
ehtfienimretedotmargorpnoitalumeSODehtnuR
retpadaehtotsnoitcennoclladnagninoitcnufsiretpada
.tcerrocera
Table 4-1
Troubleshooting the SWCA
Page 30
4.0 TROUBLESHOOTING
22
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Page 31
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
A-1
APPENDIX A – PRODUCT AND SYSTEM INFORMATION
WARRANTY
Xantrex Technology Inc., warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase, established by proof of purchase or formal warranty registration, and extends this warranty to all purchasers or owners of the product during the warranty period. Xantrex does not warrant its products from any and all defects:
• arising out of material or workmanship not provided by Xantrex or its Authorized Service Centers;
when the product is installed or exposed to an unsuitable environment as
evidenced by generalized corrosion or biological infestation;
resulting from abnormal use of the product, alteration, or use in violation of
the instructions;
• in components, parts, or products expressly warranted by another manufac­turer.
Xantrex Technology Inc., agrees to supply all parts and labor to repair or replace defects covered by this warranty with parts or products of original or improved design, at the company's option. Xantrex Technology Inc., also reserves the right to improve the design of its products without obligation to modify or upgrade those previously manufactured. Defective products must be returned to Xantrex Technology Inc., or its Authorized Service Center in the original packaging or equivalent. The cost of transportation and insurance on items returned for service is the responsibility of the customer. Return transportation (UPS Ground or equivalent) as well as insurance on all repaired items is paid by Xantrex Technology Inc.
All remedies and the measure of damages are limited to the above. Xantrex Technology Inc., shall in no event be liable for consequential, incidental, contingent, or special damages, even if Xantrex Technology Inc., has been advised of the possibility of such damages. Any and all other warranties, expressed or implied, arising by law, course of dealing, course of performance, usage of trade or otherwise, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose, are limited in duration for a period of two (2) years from the original date of purchase.
Some states or countries do not allow limitations on the term of an implied warranty, or the exclusion or limitation of incidental or consequential damage, which means the limitations and exclusions of this warranty may not apply to you. Even though this warranty gives you specific legal rights, you may also have other rights which vary from state to state.
Page 32
APPENDIX A – PRODUCT & SYSTEM INFORMATION
A-2
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
RETURN MATERIAL AUTHORIZATION POLICY
You must obtain a Return Material Authorization (RMA) number from Xantrex before returning a product directly to Xantrex. Products returned without an RMA number or shipped collect will be refused. When you contact Xantrex to obtain servcie, be prepared to supply the serial number of your product and its date of purchase as well as information about the installation and use of the unit. Record this information in “Information About Your System” on page A-3 of this guide.
RETURN MATERIAL PROCEDURE
If you are returning a product, follow this procedure:
1. Obtain an RMA number and a shipping address from Xantrex.
2. Package the unit safely, preferably using the original box and packing materials. Include the following:
• The RMA number
• A copy of your dated proof of purchase
• A return address where the repaired unit can be shipped
• A contact telephone number
• A brief description of the problem
3. Ship the unit freight prepaid to the address provided in step 1.
Page 33
APPENDIX A – PRODUCT & SYSTEM INFORMATION
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
A-3
SERVICE INFORMATION
Xantrex Technology Inc. takes great pride in its products and makes every effort
to ensure your unit fully meets your independent powering needs.
If your product needs repair, contact our Customer Service department at: (360) 435-8826 to obtain an RMA# and shipping information; or, fax this page with the following information to: (360) 474-0616.
Please provide:
Part Number: _______________________________________
Purchase Date: _____________________________________
Problem: ___________________________________________
Include a telephone number where you can be reached during business hours and a complete return shipping address (P.O. Box numbers are not acceptable).
Name: _______________________________________________
Address: _____________________________________________
City: ________________________________________________
State / Province: _______________________________________
Zip / Postal Code: _____________________________________
Country: _____________________________________________
Phone: (____) _________________________________________
FAX: (____) __________________________________________
E-mail Address: _______________________________________
Page 34
APPENDIX A – PRODUCT & SYSTEM INFORMATION
A-4
©2002 Xantrex Technology Inc.
P/N 973-0022-01-01 Rev A 04/2002
Notes:
Page 35
Page 36
t
1 360 435 8826
f
1 360 435 2229 dpm@xantrex.com www.xantrex.com
P/N 973-0022-01-01 Rev A Printed in USA