Wolf ICBIM15G, ICBIM15S Installation Instructions Manual

MULTI-FUNCTION COOKTOP
INSTALLATION INSTRUCTIONS
Model number
ICBIM15G / S
This cooktop is approv e d f o r u s e w i t h
Natura l and Propane gases.
Leav e i n s t r u c t i o n s w i t h t h e o w n e r.
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademark of Wolf Appliance, Inc.
CO N TA CT IN F O R M AT I O N
Imported and distributed by: Multyflex
Website: www.multyflex.com.au
M U LT I - F U N C T I O N C O O K T O P
M o d e l N o : I C B I M 1 5 G / S
R A T I N G P L AT E I N F O R M A T I O N
Model Number
Serial Number
3
I N S TA L L AT I O N RE Q U I R E M E N T S
IMPORTANT NOTE:
Installer:
Please read the entire Installa-
t
ion Instructions prior to installation. Save these instructions for the local inspector’s reference, then leave them w
ith the homeowner.
Homeowner:
Please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
Statutory requirements:
This appliance shall be installed in accor­dance with the manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, and AS5601 the Australian Standard for gas installation. Refer also to AS5601 for gas pipe sizing tables.
W O L F MU LT I - F U N C T I O N C O O K T O P
IMPORTANT NOTE:
Installation to be carried out only by an authorised person.
Do not modify this appliance.
A ventilation hood is recom­mended for use with the Wolf gas multi-function cooktop.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appli­ance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire depart­ment.
If the information in this book is not followed exactly, a fire or explosion may result, causing property damage, personal injury or death.
Rating plate location
Location of rating
plate under cooktop
ICBIM15 G/S
B E F O R E YOU STA RT
Statutory requirements
This appliance shall be installed in accordance with the manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, and AS5601 the Australian Standard for gas installations. Refer also to AS5601 for gas piping sizes.
Proper installation is your responsibil­ity. Have a authorised person install this cooktop. You must also ensure that electrical installation is adequate and in compliance with all local codes and ordinances.
Please check the product rating plate or Use & Care Information for type of gas needed.
Proper gas supply connection must be available; refer to Gas Supply Require­ments on page 8. Electrical ground is required; see Electrical Requirements on page 9.
Make sure you have everything neces­sary for correct installation. It is the responsibility of the installer to comply with the installation clearances speci­fied on the product rating plate. The rating plate can be found on the under­side of the cooktop.
4
This cooktop is intended for indoor use.
W O L F MU LT I - F U N C T I O N C O O K T O P
S A F E T Y C O N S I D E R AT I O N S
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety
Children should be supervised to ensure they do not play with the appli­ance.
Do not spray aerosols in the vicinity of this appliance while it is operation.
Where this appliance is installed in marine craft or caravans, it shall not be used as a space heater.
Never leave the appliance unattended when cooking with fat or oil. If could ignite if overheated.
In case of defect, switch electric power off at the mains.
Never use an appliance that is not working properly.
Do not allow the flame to extend beyond the edge of the cooking utensil. This instruction is based on safety considerations.
Do not forget that the unit becomes hot when in use. Common sense is impor­tant. Just because the flame is out, does not mean parts cannot still be hot.
Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapours and liquids.
5
I N S TA L L AT I O N I N S T R U C T I O N S
O V E R H E A D C A B I N E T D I M E N S I O N S
C)
Minimum spacing between overhead side cabinets must be greater than or equal to the nominal width of the module(s).
D)
Minimum 457 mm vertical distance from the countertop to the bottom of side cabinets within minimum side clearance.
E)
Minimum vertical distance between the countertop and combustible materials above the cooktop module must be 762 mm. Where this is not practicable, the underside of any combustible material less than 600 mm above the burner shall be protected by non-combustible mill board at least 6 mm thick which is covered with sheet metal not less than 0.4 mm thick, or shall be protected by an equivalent material, extending at least 225 mm beyond the sides of the cooktop.
Range hoods and exhaust fans shall be installed in accordance with the manufac­turer’s instructions. However, in no case shall the clearance between the top of the burner and the underside of the range hood be less than 750 mm, or an overhead exhaust fan, 750 mm.
F)
Minimum 64 mm from rear wall.
G)
Maximum 330 mm depth of overhead and side cabinets directly above and within side clearance.
S I T E PR E PA R AT I O N
Check the location where the cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Do not obstruct flow of combustion and ventilation air.
IMPORTANT NOTE:
Installation of the Wolf gas multi-function cooktop must meet the following location requirements. All dimen­sions listed are minimum requirements for safe operation. Refer to the illustration on this page.
Failure to locate the cooktop module without the proper clearances will result in a fire hazard.
C
G
D
A
B
B
E
F
Minimum installation clearances
L O C A T I O N I N C O U N T E R T O P
A)
Minimum flat countertop surface. Must be equal to or greater than the width of the module(s).
B)
Minimum 200 mm wide clearance from the periphery of the nearest burner to any combustible surface up to 457 mm above the countertop (noted by shaded area).
If the distance measured from the periphery of the burner to any vertical combustible surface, is less than 200 mm, the surface shall be protected in accordance with clause 5.12.1.1 and 5.12.1.2 of AS 5601.
Loading...