Wolf ICBDF486C series, ICBDF366 series, ICBDF364C series, ICBDF364G series, ICBDF486G series Installation Instructions Manual

...
DUAL FUEL RANGES
INSTALLATION INSTR UCTION S
Natu ral ga s .
Le av e instructio ns w it h the owner.
This cookto p is a pprov ed for use with
Mo del Ser ies
ICBDF366
ICBDF304
ICBDF364C ICBDF364G ICBDF486C ICBDF486G ICBDF484CG ICBDF484F ICBDF606CG ICBDF604CF
As you read this use & care information, take particular note of the CAUTION and WARNING symbo ls when they appear. This information is important for safe and efficient use of the Wolf equipment.
In addition, this use & care information may signal an IMPORTANT NO TE which highlights information that is especially important.
signals a s ituation wher e minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
WOLF®is a registered trademar k of Wolf Appliance, Inc.
I NS T A LL A TI O N R E QUIREMENTS
IMPORTANT NOTE: This installation must be completed byaqualified installer, service agency or gas supplier.
IMPORTANT NOTE:
Save these installation
instructions for the local inspector’s use.
Installation to be carried out only by an authorised person.
Do not modify this appliance.
Please read the entire installation instruc­tions prior to installation.
Installer:
please retain these instructio ns for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire use & care in
formation
prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance with local codes. The correct voltage, frequency and amperage must be supplied to the appliance fromadedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequenc y, and amperage ratings are listed on the product rating plate.
Record the model and serial nu mbers before installing the dual fuel ran g e. Both numbers are listed on the rating plate, loc ated rear of removable lower panel.
W O L F DU A L F UEL RANGE S
IMPORTANT NOTE:
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammab le vapors and liquids in the vicinity of this or any other appliance.
A ventilation hood is recomme nded for use with the Wolf dual fuel range.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric al switch.
Do not use an y phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire depar
tment.
If the information in this book is not followed exactly,afire or explosion may result, causing property damage, personal injury or death.
R A T I N G PL A T E I N FORM A T I O N
Model Number
Serial Number
CONT A C T INFOR M A T I O N
Imported and distributed by: Multyflex
Website: www.multyflex.com.au
IMPORTANT NOTE:
Statutory requirements: This
appliance shall be installed in accordance with the manu fac­turer’s installation instructions, local gas fitting regulations, municipal building codes, electri­cal wiring regulations, and AS/NZ5601 the Australian Standard for gas installations. Refer also to AS/NZ5601 for gas pipe sizing tables.
Unsuitability for use in marine craft, c aravans or mobile homes, unless each burner is fitted with a flame safeguard.
3
B EF O R E Y O U S T A R T
Proper installation i s your responsibility. Installations must be performed by a qualified or licensed contractor, plumber or gas fitter, qualified or licensed by the state, province or region w here th is appl iance is being installed. You must also ensure that electrical installatio n is a dequate and conforms with all lo cal cod es and ordinances.
Proper gas supply mu st be available; refer to gas supply requir ements on page 9. Electrical ground is requi
red; see electrical
requirements on page 10.
Check the location w here th e range will be installed. The locati on shou ld be away from strong draft areas, such as windows, doo r s and strong heating v ents or fans. Do not obstruct the flow of air. The area in which you are installing t his app liance must have an adequate supply o f fresh air to ensure proper combustion and ventilation.
Make sure you have everything necessary for proper installati o n. It is the responsibil­ity of the i
nstaller to comply w ith the instal­lation clearances spe cified on the product rating plate. The ra ting pl ate is located rear of removable lower p a nel.
All openings in the wall or floor where the range is to be inst a lled m u st be sealed.
The cooking range to be installed only on the floor.
When installing the range under existing cabinets where the i nstallation does not meet the minimum cab inet cl earances, install a ventilation hood or other non­combustible surface a bove th
e range to avoid burn hazards. Refer to minimum clearances on page 3 .
V EN T I L AT IO N O P T I O N S
IMPORTANT NOTE:
A suitable ventilatio n hood must be install ed. We recomm end a Wolf Pro Ventilation Hood be installed with the Wolf dual Fuel Range. Con tact yo ur Wolf deal e r for details.
IMPORTANT NOTE:
When installing a ve n tila­tion hood, refer to the specific requirem ents of the hood for the minimum dimension to countertop.
I NS TA L L AT I ON S P E C I F I C A T I O N S
Wolf dual fuel ranges come in 762 mm, 914 mm, 1219 mm and 1524 mm widths. Illustrations on page s 4–
7 provide the overal l dimensions and instal l ation specifications for each width of dual fuel range.
Each range is design ed to fit between cabinets set at the distance specified by the un it. For example, a 914 mm r ange wi ll fit a 914 mm opening. The exceptio n is t he 1524 mm unit which will require a 1530 mm opening.
IMPORTANT NOTE:
Cabinet opening dimen ­sions shown in the installation specifica t ions illustrations must be used. These dimensi ons provide for required clearanc
es.
Each unit is designe d with a terminal block on the rear of the ran g e. Hav e a qu alified electri­cian or installer wi re your unit from the elec t ri­cal supply, through the knock out in the unit base and to the ter minal b lock on the range.
IMPORTANT NOTE:
Locate the electrical supply within dimensi ons sho wn in the installation specifica tions i llustrations and flush with back wall .
Refer to the install ation s pecifications illustra­tion for your model on pages 4– 7 for the ex
act rough opening dimensi ons and location of the gas supply and elect rical.
Wolf dual fuel ranges usin g natur al gas will operate up to an al t itude of 2438 m without any adjustment. Natur a l gas and LP gas instal­lations from 2438 m to 3353 m need the high altitude conversion k it.
I NS TA L L AT I ON I N S T R U C T I O N S
I NS TA L L AT I ON S P E C I F I C A T I O N S
M I N I M U M C L E A R A N C E S
IMPORTANT NOTE:
Caution must be used in planning the proper installation of the Wolf dual fuel range to a void fi re or damag
e to adjacent cabinetry or kitchen equipment. Be sure to follow t he mini mum cle arances established in the f inished rough opening dimensions.
For installation against a rear combustible surface a 254 mm classic stainless steel riser must be used. Refer part number 8 04387.
Refer to the install ation s pecifications illustra­tion for your model on pages 4– 7 for the exact rough opening dimensio ns.
Maintain th e fol lowing clearances to combustible materials:
Minimum 457 mm clear ance fr om bott om of upper cabinet to countertop, within 152 mm minimum side clearance.
Minimum 762 mm clear ance b e tween c oun­tertop and bottom of wood or metal cabinet, which is pr otected by not less than 6 mm flame retardant millboard covered with not less than No. 28 MSG sheet st e el, .4 mm stainless stee l, or .6 mm aluminum or .5 mm copper.
Minimum 914 mm clear ance b e tween c oun­tertop and bottom of an unprotected wood or metal cabinet.
Bottom of ventilation hood must be 600 mm minimum to 9 14 mm maximum from countertop.
I S L A N D | P E N I N S U L A I N S T A L L A ­T I O N S
For island i n stallations,
the range should not be installed wit hin an enclosure having an adjacent rear wall l ess tha n 305 mm from the rear of the unit th at rise s above the countertop.
For peninsula installati ons,
the range must have a 152 mm minim u m clea rance t o the side wall, left or right side, and 305 mm mi nimum clearance to the rea r wall.
Refer to the install a tion s pecifications illustra­tion for your model on pages 4– 7 for the exact rou
gh opening dimensions .
Failure to locate the range wit h out t he proper clearances will result in a fire hazard.
4
W
ICBDF304
OLF
330 mm
LOCATION OF
ELECTRICAL
914 mm
937 mm
TO COOKING SURFACE
600 mm min
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
VENTILATION HOOD
457 mm min
TO COUNTERTOP
LOCATION OF GAS AND ELECTRICAL EXTENDS 57 mm ON FLOOR FROM BACK WALL
762 mm
FINISHED ROUGH
OPENING WIDTH
83 mm
216 mm
254 mm
LOCATION
OF GAS SUPPLY
600 mm min TO
914 mm max
TO BOTTOM OF
VENTILATION HOOD
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGE TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0 mm TO NON-COMBUSTIBLE MATERIALS
330 mm
max
152 mm
min TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
759 mm
OVERALL WIDTH
937 mm
ISLAND
TRIM
1165
mm
WITH
254 mm
RISER
1419
mm
WITH
508 mm
RISER
1038
mm
WITH
127 mm
RISER
1194 mm
664 mm
635 mm
613 mm
699 mm
235 mm
749 mm
OVERALL DEPTH
*937 mm MIN TO 991 mm MAX.
911 mm
937 mm
OVERALL
HEIGHT TO
COOKING
SURFACE*
Overall Width 759 mm
Overall Height (to cooking surface) 937 mm
Overall Depth 749 mm
Opening Width 762 mm
DUAL FUEL RANGE
IMPORTANT NOTE: In non-island applications, a minimum 127 mm riser is required for model ICBDF304.
Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200 mm, the surface shall be protected in accordance with AS/NZ5601.
Note B: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 mm is required for a range hood and 750 mm for an exhaust fan
.
5
I NS T A LL A TI O N I N S T R U C T I O N S
483 mm
LOCATIONOF
ELECTRICAL
914 mm
937 mm
TO COOKING SURFACE
VENTILATIONHOOD
457 mm min
TO COUNTERTOP
LOCATIONOF GAS AND ELECTRICAL EXTENDS 76 mm ON FLOOR FROM BACK WALL
914 mm
FINISHED ROUGH OPENING WIDTH
83 mm
216 mm
381 mm
LOCATION
OF GAS SUPPLY
mm min TO
914 mm max
TO BOTTOMOF
VENTILATIONHOOD
600 mm min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
762 mm min
FOR CHARBROILER
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGE TO
COMBUSTIBLE REAR WALL ABOVECOUNTERTOP–
330 mm
max
911 mm
OVERALLWIDTH
1194 mm
699 mm
235 mm
749 mm
OVERALL DEPTH
LEGS AND CASTERS ALLOW 54 mm HEIGHT ADJUSTMENT
911 mm
937 mm
OVERALL
HEIGHT TO
COOKING SURFACE
616 mm
641 mm
1064
mm
WITH
127 mm
RISER
1191
mm
WITH
254 mm
RISER
1445
mm
WITH
254 mm
RISER
I N S T A L L A T I O N SPE C I F I C A T I O N S
O VERA L L D I M E N S I O N S
Overall Width 911 mm
Overall Height (to cooking surface) 937 mm
Overall Depth 749 mm
Opening Width 914 mm
Dimensions may vary to±3 mm.
9 14 m m DU A L F U E L R A N G E S
M O D E L I C B D F 3 6 6
M O D E L I C B D F 3 6 4 C
M O D E L I C B D F 3 6 4 G
IMPORTANT NOTE: In non-island applications, a mini mum 127 mm riser is required for model ICBDF366 and minimum 254 mm ri ser required for models ICBDF364C and ICBDF364G installed against a combu stible surface. The island trim and 127 mm riser may on ly be used against a non-combustible surface for m odels ICBDF364C and ICBDF364 G .
NOTE
A
NOTE
B
Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200 mm, the surface shall be protected in accordance with AS/NZ5601.
Note B: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 mm is required for a range hood and 750 mm for an exhaust fan
.
600
50 mm TO NON-COMBUSTIBLE MATERIALS
6
W O L F DU A L F UE L R A N GE S
330 mm
LOCATIONOF
ELECTRICAL
914 mm
937 mm
TO COOKING SURFACE
VENTILATIONHOOD
LOCATIONOF GAS AND ELECTRICAL EXTENDS 76 mm ON FLOOR FROM BACK WALL
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGE TO
COMBUSTIBLE REAR WALL ABOVECOUNTERTOP–
1219 mm
FINISHED ROUGH OPENING WIDTH
610 mm
83 mm
254 mm
LOCATION
OF GAS SUPPLY
457 mm min
TO COUNTERTOP
mm min TO
914 mm max
TO BOTTOMOF
VENTILATIONHOOD
600 mm min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
762 mm min
FOR CHARBROILER
330 mm
max
1216 mm
OVERALLWIDTH
1194 mm
699 mm
235 mm
749 mm
OVERALL DEPTH
LEGS AND CASTERS ALLOW
54 mm HEIGHT ADJUSTMENT
911 mm
937 mm
OVERALL HEIGHT TO COOKING
SURFACE
616 mm
641 mm
1064
mm
WITH
127 mm
RISER
1191
mm
WITH
254 mm
RISER
1445
mm
WITH 254 mm RISER
I N S T A L L A T I O N S P E C I F I C A T I O N S
O V E R A L L D I M E N S I O N S
Overall Width 1216 mm
Overall Height (to cooking surface) 937 m m
Overall Depth 749 mm
Opening Width 1219 mm
Dimensions may vary to±3 mm.
1 21 9 m m D U A L F U E L R A N G E S
GC8 44FDBCI
I C B D F 4 8 4 F
C8 64FDBCI
I C B D F 4 8 6 G
IMPORTANT NOTE: In non-island applications, a minimum 254 mm ris er is required for all 1219 mm models installed against a combustible surface. The is land trim and 127 mm riser may only be used against a no n -combustible surf ace.
NOTE
B
Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200 mm, the surface shall be protected in accordance with AS/NZ5601.
Note B: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 mm is required for a range hood and
750 mm for an
exhaust fan
.
NOTE
A
600
50 mm TO NON-COMBUSTIBLE MATERIALS
Loading...
+ 14 hidden pages