Contents
Important Note
Wolf Induction Cooktops . . . . . . . . . . . . . . . . . . . . . . . 3
Induction Cooktop Specifications . . . . . . . . . . . . . . . . 4
Induction Cooktop Installation . . . . . . . . . . . . . . . . . . 12
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications are subject to change at any time
without notice. Visit wolfappliance.com/specs for the most
up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.

Wolf Induction Cooktops 3
M
E
L
T
O
F
F
H
I
-
P
O
W
E
R
H
I
G
H
S
I
M
O
F
F
O
N
H
I
-
P
O
W
E
R
H
I
G
H
S
I
M
O
F
F
O
N
M
E
L
T
H
I
G
H
O
F
F
O
N
wolfappliance.com/specs
Induction Cooktop Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf authorized service center
technician.
Read this entire installation guide prior to installation and
save for the local inspector’s reference. The homeowner
should keep this installation guide for future reference.
This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal
and local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly
sized circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are listed on the
product rating plate.
Record the model and serial numbers before installing the
induction cooktop. Both numbers are listed on the product
rating plate, located on the underside of the cooktop.
Refer to the illustration below.
olf Induction Cooktop
W
Model Number
Serial Number
RATING PLATE
Location of rating plate.

Induction Cooktop Specifications 4
31/2" (
89)
11/4" (32)
7
/8" (22)
ALL SIDES
T
ERM BOX
21" (533)
15"
(381)
30" (762)
31/2" (89)
11/4" (32)
7
/8" (22)
ALL SIDES
T
ERMINAL BOX
2
1"
(533)
3
6"
(914)
31/2" (89)
11/4" (32)
7
/8" (
22)
ALL SIDES
TERMINAL BOX
2
1"
(533)
30" (762)
4" (102)
11/4" (32)
7
/8" (22)
ALL SIDES
TERMINAL BOX
21" (533)
36" (914)
4" (102)
11/4" (32)
7
/8" (22)
ALL SIDES
TERMINAL BOX
21" (533)
Overall Dimensions
15" (381) FRAMED
30" (762) FRAMED
30" (762) UNFRAMED
36" (914) FRAMED
36" (914) UNFRAMED

Induction Cooktop Specifications 5
35/16"
(84)
23/16"
(56)
15
/16"
(24)
7
/8"
(22)
11/4" (32)
wolfappliance.com/specs
Installation Requirements
IMPORTANT NOTE: I
nstallation of the induction cooktop
must meet location requirements shown in the installation
illustration for your specific model on the following pages.
All dimensions listed are minimum requirements for safe
operation.
Wolf induction cooktops are intended for indoor use. For
ease of installation, Wolf recommends using 33" (838)
wide cabinets with 30" (762) cooktops and 39" (991)
cabinets with 36" (914) cooktops. They are designed to fit
a standard 24" (610) deep base cabinet with a 25" (635)
deep countertop. Before making the countertop cut-out,
verify that the cooktop will clear the side walls of the base
cabinet.
A minimum height clearance of 6
1
/4" (159) is required from
the top of the countertop to any combustible surface
directly below the cooktop. If a shelf is installed below the
unit, a 1" (25) gap at the rear of the cabinet shelf is necessary to allow for proper ventilation.
Clearance is required for the terminal block located at the
right rear of the cooktop. Refer to the illustration below for
dimensions.
nframed induction cooktops can be mounted flush with
U
the top of the countertop or as a frameless installation
with the glass-ceramic top mounted on top of the countertop surface. In either installation the countertop cut-out
dimensions are the same. If the cooktop is to be mounted
flush with the countertop, a recessed area surrounding the
countertop cut-out must be provided.
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface or stone countertop surfaces only.
It is recommended that you use a Wolf cooktop ventilation
hood, pro hood or hood liner with the induction cooktop.
Framed induction cooktops can accommodate a Wolf
downdraft ventilation system. Refer to the Wolf design
guide.
Failure to locate the cooktop without proper clearances
will result in a fire hazard.
Terminal block dimensions.