Wolf CHR-4-18, CHR-2-18-FT11, CHR-0-18-FT22 Quick Manual

Item #_____________ C.S.I. Section 11420
CHALLENGER SERIES
23" SINGLE OVEN RANGE
C23S
STANDARD 18" OVEN MODELS: BTU/HR. CHR-4-18 4 Open Burners 124,000
CHR-2-18-FT11 2 Open Burners/
11" Griddle on Left 92,000
CHR-0-18-FT22 0 Open Burners/
22" Griddle 40,000
KEY FEATURES:
Stainless steel exterior.26,000 BTU/hr. open burners with lift-off heads.Flashtube pilot ignition system for automatic burner light-
ing.
Single piece heavy-duty cast iron top grate measures
1
8"w x 251⁄2"d. (One grate for every two open burners)
11
Full width pull out crumb tray. 20,000 BTU/hr. standard oven cavity measures 18"w x
22"d x 13"h. Thermostat adjusts from 250° to 500°F.
One oven rack and four rack positions.
3
4" rear gas connection and gas pressure regulator.
➤ ➤ One year limited parts and labor warranty.
TOTAL INPUT
MODEL: CHALLENGER SERIES
Model CHR-4-18
Design Certified by the American Gas Association Design Certified by the Canadian Gas Association Certified by the National Sanitation Foundation
OPTIONAL FEATURES:
41⁄2" stainless steel stub back. ➤Thermostatically controlled griddle.
ACCESSORIES: Packaged separately
Extra oven rack.Extra rack guide(s).Set of four casters (two locking).Seismic legs. Reinforced highshelf for mounting Cheesemelter.
EXTERIOR DIMENSIONS:
1
2"w x 323⁄4"d x 571⁄2"h on 6" adjustable legs.
22 37" working height.
23" Single Oven Range
F-39051 (6/05)
Wolf Range Company Division of ITW Food Equipment Group LLC (800) 366-9653 www.wolfrange.com
Challenger Series
23" Single Oven Range
C23S
TOP OPTIONS:
11" and 22" wide griddle tops in 1" thickness. 20,000
BTU/hr. input per 11" griddle width. Choice of manual or thermostatic controls, one control per burner. Spatula width front grease trough.
CHR-4-18 CHR-2-18-FT11 CHR-0-18-FT22
INSTALLATION REQUIREMENTS:
1. A pressure regulator sized for this unit is included. Natural gas 5.0" W.C., propane gas 10.0" W.C.
3
2. Gas line connecting to range must be connectors are used, the inside diameter must be the same
3
4" iron pipe.
as the
3. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org. When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance with ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may be obtained from The American Gas Associa­tion, 400 N Capitol St. NW, Washington, DC 20001, www.AGA.org.
5. Clearances: Combustible Non-combustible
Rear 2" 0" Sides 10" 0"
6. For proper combustion, install equipment on adjustable legs or casters provided with unit. On curb or platform, allow
1
2" front overhang (see adjacent diagram). Leveling bolts
3 are required for curb installation. Specify when ordering.
4" or larger. If flexible
NOTE: In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39051 (6/05)
Loading...