Wolf C24S, C72S, C36S, C60S, C48SS User Manual

...
0 (0)

INSTALLATION & OPERATION MANUAL

CHALLENGER XL Series

Gas Restaurant Ranges

MODELS:

C24S C36(S,C)

C48(S,C) C48SS

C60(S,C)(S,C) C72(S,C)(S,C)

www.wolfrange.com

ITW Food Equipment Group, LLC

RETAIN THIS MANUAL FOR FUTURE USE

10405 Westlake Drive

 

Charlotte, NC 28273

FORM F35696 Rev. E (07-08)

IMPORTANT FOR YOUR SAFETY

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.

POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.

IMPORTANT

In the event a gas odor is detected, shut down units at main shutoff valve and contact the local gas supplier for service.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

IN THE EVENT OF A POWER FAILURE, DO NOT

ATTEMPT TO OPERATE THIS DEVICE.

- 2 -

INSTALLATION, OPERATION AND CARE OF CHALLENGER XL SERIES GAS RESTAURANT RANGES

PLEASE KEEP THIS MANUAL FOR FUTURE USE

GENERAL

Wolf ranges and ovens are produced with quality workmanship and material. These ranges are designed with efficiency in cooking performance, sanitation and ease of cleaning ability in mind. Proper installation, usage and maintenance of your range will result in many years of satisfactory performance.

The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.

OPTIONAL FIELD INSTALLABLE ACCESSORIES

DESCRIPTION

ACCESSORIES

Flue Devices

- 23" (584 mm) high stainless steel backsplash with broiler mounting brackets

 

- Stainless steel stub riser

 

 

Flex Hose and Quick

- ¾” (18.75 mm) flex hose / disconnect, 4’ (1219 mm long).

Disconnect

- 1" (25 mm) flex hose / disconnect, 4' (1219 mm) long.

 

 

Oven Racks

- 1 extra rack with standard and convection ovens.

 

- 1 extra pair of rack slides with standard ovens.

Casters

- Set of four 6" (152 mm) casters.

 

- Set of six 6" (152 mm) casters.

INSTALLATION

UNPACKING

This range was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the range is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Carefully unpack range(s) and place in the approximate installation position. Remove parts (packed in a cardboard box) from oven cavity.

If burner has been shipped using any package strapping devices, remove these before installing the range.

Before installing, check the type of gas supply (natural or propane) to make sure they agree with the specifications on the rating plate located on the inside of the kick panel. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer immediately.

- 3 -

LOCATION

The equipment area must be kept free and clear of combustible substances.

Installation clearances:

COMBUSTIBLE

NON-COMBUSTIBLE

 

CONSTRUCTION

CONSTRUCTION

Back:

6" (152 mm)

0"

Right Side:

10" (254 mm)

0"

Left Side:

10" (254 mm)

0"

The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 35" (889 mm) is required.

The ranges are suitable for installation on combustible floors when 6" (152 mm) adjustable legs or casters are used. When legs or casters are removed, use only on noncombustible floors, curb, or platform, with front appliance base projecting 3" (76 mm) beyond curb or platform.

The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.

INSTALLATION CODES AND STANDARDS

Your Wolf Range must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.

NOTE: In the Commonwealth of Massachusetts

All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.

3.NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.CAN/CSA-B149.1 Natural Gas Installation (latest edition)

3.CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3

The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.

- 4 -

Wolf C24S, C72S, C36S, C60S, C48SS User Manual

LEG/CASTER ASSEMBLY

The range is shipped fully assembled, except for the legs. The range is provided with 6"(152 mm) adjustable stainless steel legs (hardware included), packaged in a box located inside of the oven. A set of 6"(152 mm) casters are available as an optional field installable accessory.

RANGE SERIES

LEGS TO INSTALL

CASTERS TO INSTALL

C24

4

4

C36

4

4

C48

6

6

C60

6

6

C72

6

6

Installation of Legs/Casters:

1.Carefully tip range on its side.

2.Align holes in leg/caster mounting plate with pre-drilled holes in bottom of range located in each of the four corners. Two additional legs/casters must be installed on the C48, C60, and C72. The additional legs/casters should be installed utilizing the pre-drilled holes shown in Figure 1.

Figure 1 - Cross Chassis Leg/Caster Mounting

3.Attach mounting plate to bottom of range using four ¼ - 20 x ⅝“ self tapping screws (provided). If casters are being installed, the locking casters should be mounted on the front.

4.After all legs/casters have been installed, carefully return the range to its upright position.

(For additional leg information, see Leveling section of this manual).

Ranges mounted on casters must use a flexible connector (not supplied by Wolf) that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69•CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41•CSA 6.9. In addition, adequate means must be provided to limit movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit appliance movement. Attach the restraining device at the rear of the range.

- 5 -

If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position.

If the range is installed on casters and is moved for any reason, it is recommended that the range be re-leveled front to back and side to side for even baking.

LEVELING

To level the range, place a carpenter's level on the range top and check leveling of the unit side to side and front to rear. Achieve leveling by turning each foot section of the unit's leg as needed. Turning the foot in a counter clockwise direction will increase height and clockwise will decrease.

GAS PRESSURE REGULATOR

A preset gas pressure regulator and street elbow is shipped with the range. This regulator must be installed by an authorized service person before the unit is placed into operation. See full unit data plate located on the rear of the range, or the secondary data plate, riveted to the kick panel, for pressure regulator setting information. If a manometer is being used, utilizing one of the available pressure taps in the manifold, the manifold pressure with one burner on should be ± 0.3" W.C. of the value indicated on the rating plate.

1.Locate the gas connection pipe protruding through the back of the unit.

2.Cover the pipe threads with pipe joint compound resistant to propane gases.

3.Screw the regulator onto the pipe hand tight with flow direction arrow pointing towards the back of the unit and the regulator adjustment in the up right position.

4.With a pipe wrench, tighten the regulator securely in the upright position. (The regulator is preset and should not require any additional adjustments.) The pressure regulator must be mounted horizontally to ensure the proper preset outlet pressure. If mounted in any other direction, the outlet pressure must be rechecked and possibly reset. A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct the limiter or the gas regulator, as obstruction may cause the regulator to malfunction.

GAS CONNECTIONS

All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.

Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When test pressures exceed ½ psig (3.45 kPa), the range and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are ½ psig (3.45 kPa) or less, the range must be isolated from the gas supply system by closing its individual manual shutoff valve.

- 6 -

FLUE CONNECTIONS

DO NOT obstruct the flow of flue gases from the flue located on the rear of the range. Proper venting of flue gas is vital to the safe and efficient operation of the range. Problems arising from the intentional obstruction of the flue will result in voiding of warranty. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.

From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18" (457 mm) must be maintained. Information on the construction and installation of ventilating hoods may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

ELECTRICAL CONNECTIONS

Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.

Disconnect the electrical power to the machine and follow Lockout / Tagout procedures.

Appliances equipped with a flexible electrical supply cord are provided with a three-prong grounding plug. It is imperative that this plug be connected into a properly grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong from this plug.

The convection range is designed for 120 volt power supply and is provided with a flexible electric supply cord and plug that must be plugged into the proper receptacle. Do not connect the convection range to electrical supply until after gas connections have been made. The wiring diagram for the convection range is located on the rear of the appliance.

OPERATION

The appliance and its parts are hot. Use care when operating, cleaning, or servicing the appliance.

CONTROLS

Open Top Burner Valve — Allows gas to flow to the top burners. To open valve, turn knob counterclockwise. To close valve, turn knob clockwise.

Manual Griddle Valve — Allows gas to flow to the griddle burners. To open valve, turn knob counterclockwise. To close valve, turn knob clockwise.

Oven Thermostat — Regulates oven temperature. The thermostat temperature range is from LOW at approximately 250°F (121°C) to HI at approximately 500°F (260°C). Turn the thermostat counterclockwise to increase temperature and clockwise to decrease temperature. Oven temperature regulation is the most accurate between 300°F (149°C) and 500°F (260°C).

- 7 -

Griddle Thermostat — Regulates griddle temperature. The thermostat temperature range is from LOW at approximately 200°F (93°C) to HI at approximately 550°F (288°C). Turn the thermostat clockwise to increase temperature and counterclockwise to decrease temperature.

Safety Valve – Monitors standing pilot. The oven and thermostatic griddle feature a standing pilot that must be manually lit. The pilot is monitored by a thermocouple and pilot safety valve. If the pilot goes out, the safety valve will shut-off the gas supply to the pilot and main burners.

Fan Switch – Turns fan on and off (Convection Ovens only). Fan turns on when door is closed. Fan turns off when door is opened.

BEFORE FIRST USE

Ovens

New ovens require a burn off period to break in the oven and eliminate unappetizing odors from penetrating the food product. These odors are typically from curing of the porcelain enamel oven cavity parts.

Turn on gas to unit and set the thermostat to 475°F (246°C). Allow the oven to operate at this temperature for 30 to 45 minutes.

Griddles

Before leaving the factory the griddle is coated with vegetable oil as a rust inhibitor. Remove this film when the griddle plate is being cleaned prior to its first cooking use. Heat the griddle to 200-300°F to loosen and melt the coating, then clean the surface with a non-corrosive, grease dissolving commercial cleaner, following the manufacturer’s directions. Rinse thoroughly and wipe dry with a soft clean cloth. Clean all accessories.

The griddle plate is steel, but the surface is soft and can be scored or dented by careless use of spatulas or scrappers. Be careful not to dent, scratch or gouge the plate. Do not try to knock off loose food that may be on the spatula by tapping the corner edge of the spatula on the griddle surface.

Season the griddle to avoid possible surface corrosion before first use, and after every cleaning. Heat griddle to a low temperature (300-350°F) and apply a small amount of cooking oil – about one ounce per square foot of surface. Use a soft lint-free cloth to spread the oil over the entire griddle surface to create a thin film. Wipe off any excess oil with a cloth. Repeat the procedure until the griddle has a slick, mirror-like finish.

LIGHTING AND SHUTTING DOWN PILOTS

TOP SECTIONS

Open Top, Manual Griddle

1.Remove front row of grates (Open Top Only).

2.Turn the main gas supply valve to the ON position.

3.Light all standing pilots.

Open Top - Pilot access can be reached under the grate support beam running from left to right. Manual Griddle – Pilot access can be reached under the griddle plate through the slotted opening in

the manifold cover near the burner valve knob.

-8 -

4.Turn the burner valve ON to the desired heat.

5.If burners fail to light, turn off all valves, and then call an authorized installation or service person.

6.To shut down, turn the burner valve to the OFF position.

7.For complete shut down, turn all burner valves to the OFF position. Turn off main gas supply.

Thermostatic Griddle

1.Turn the thermostat to the OFF position.

2.Turn the main gas supply valve to the ON position.

3.Depress and hold the red button on the safety valve and light the pilot through the slotted opening in the manifold cover near the burner valve knob.

4.Hold red button down for at least 30 seconds.

5.When button is released, pilot should remain lit.

6.Pilot flame must be high enough to heat thermocouple.

7.Turn thermostat to desired temperature setting.

8.If ignition fails, turn the control knob to OFF. Wait 5 minutes and repeat the above procedure.

DO NOT attempt to relight pilot without waiting 5 minutes.

9.For temporary or nightly shutdown, turn control knob to OFF position.

10.For complete shutdown, turn control knob to OFF position, and turn off main gas supply.

OVEN SECTION - Standard Oven with Standing Pilot, Convection Oven with Standing Pilot

1.Turn thermostat to OFF position.

2.Turn the main gas supply valve to the ON position.

3.Lift up on louvered kick panel and rotate down 90°.

4.Depress red button on safety valve and light pilot through opening in burner box area.

5.Hold red button down for at least 30 seconds.

6.When button is released, pilot should remain lit.

7.Pilot flame must be high enough to heat thermocouple.

8.Return louvered kick panel to original position.

9.Convection Oven – Turn on fan switch located between oven control knob and pilot safety valve.

10.Turn thermostat to desired temperature setting.

-9 -