INTRODUCTION
The White-Rodgers Air Cleaner Compartment comes complete with a 5” media furnace air filter. This filter must be changed every three months to maintain efficiency of the filter and furnace system. For maximum efficiency, the compartment can be upgraded to a White-Rodgers Electronic Air Cleaner.
Please read instructions before installing and using the Air Filter Compartment.
▲! CAUTION
The fiber filter used in this cabinet for air cleaning must be replaced every 90 days. Your heating and cooling efficiency will decrease due to insufficient air flow when filter becomes dirty.
▲! WARNING
Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, and potential hazards.
Installation should be performed only by a qualified service provider.
Failure to do so could result in reduced performance of the unit, serious personal injury or death.
GUARANTEE
White-Rodgers will not assume any responsibility for component failures due to incorrect installation procedures.
RULES FOR SAFE INSTALLATION
AND OPERATION
1.Read the Owners Manual and the Rules for Safe Operation carefully. Failure to follow these rules and instructions could cause a malfunction of filter or unsatisfactory service.
▲! WARNING
Installation of this unit must comply with local electric codes or other applicable codes.
Review and understand local codes prior to installation.
▲! WARNING
Before installing or servicing, always shut off electricity. This will prevent any electrical shocks.
2.Follow a regular service and maintenance schedule for efficient operation.
TABLE OF CONTENTS |
|
Rules for Safe Installation and Operation ............ |
2 |
How the Air Filter Works ...................................... |
3 |
Construction of the Air Filter Compartment ......... |
3 |
Preinstallation ....................................................... |
4 |
Installation ............................................................ |
6 |
Maintenance ......................................................... |
7 |
Repair and Upgrade Parts ................................... |
7 |
DID YOU GET THE RIGHT SIZE
AIR FILTER COMPARTMENT
Model ACB & ACM1000 are designed for heating or cooling blowers delivering 600 to 1200 cubic feet of air per minute (cfm.)
Model ACB & ACM1400 are designed for heating or cooling blowers delivering 1000 to 1600 cfm.
Model ACB & ACM1600 are designed for heating or cooling blowers delivering 1200 to 1800 cfm.
Model ACB & ACM2000 are designed for heating or cooling blowers delivering 1600 to 2200 cfm.
Before installing the filter, make sure you have selected the proper size unit for your heating and cooling system requirements. See specifications on page 4.
BASIC TOOLS REQUIRED
Tin Snip
Screwdriver
Rule or Tape Measure
Drill
2
|
|
|
5" FILTER |
||
HOW THE AIR FILTER WORKS |
|
|
|
|
|
|
|
|
|
|
|
Dirty air flows through your return air ducts and enters the |
DIRTY AIR IN |
|
|
FILTERED AIR OUT |
|
compartment where particles (hair, lint, etc.) are removed |
|
|
|||
|
|
|
|
|
|
by the filter. See figure 1. |
|
|
|
|
|
|
|
|
|
|
Filtered air re-enters to the supply duct system of your building.
Figure 1
CONSTRUCTION OF THE AIR FILTER COMPARTMENT
Not only is your air filter compartment easy to install, it is
also easy to maintain. Its basic components, and their AIR FILTER COMPARTMENT
functions, are as follows: (See Figure 2)
5" FILTER
Air Filter Compartment- mounts to existing duct work and
houses the filters or optional electronic air cleaner DOOR cells.
NOTE: To upgrade your air filter compartment with a high efficiency Electronic Air Cleaner, use the ACR (Air Cleaner Retrofit) Kit for your model. See page 7 for details.
5” Filter - collects dust, dirt and other particles.
Figure 2
3