White Rodgers 1F82-261 User Manual

4 (1)

1F82-261

Programmable Electronic Digital

Heat Pump Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs.

Features:

Separate 5-day (weekday) and 1-day/1-day (Saturday/Sunday) programmingwithfourseparatetime/temperatureperiodsperday

Simultaneous heat and cool program storage

Preprogrammed temperature control

Optional battery back-up for AC power loss

DESCRIPTION

LCD continuously displays set point, and alternately displays time and room temperature

Continuous Backlit display option

Temperature override until next program period

Manual program override (HOLD temperature)

Temporary HOLD

°F/°C convertibility

Temperature range 45° to 90°F

R, C, Y, W2, G, O/B, E, and L terminals for single or twotransformer systems

This thermostat is intended for use with a low voltage NEC Class II system. Do not use this thermostat with a line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.

! CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

PRECAUTIONS

! WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

Thermostat installation and all components of the system shall conform to Class II (current limited) circuits per the NEC code. Failure to do so could cause a fire hazard.

SPECIFICATIONS

ELECTRICAL DATA

Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.

0.05 to 1.0 Amps (Load per terminal)

1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45°F to 90°F (7°C to 32°C)

Operating Ambient Temperature Range:

32°F to 105°F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

APPLICATIONS

For use with the following Class II systems:

Standard heat pump systems with electric, gas or oil Aux heat with 24VAC Hot and Common available

Single-stage heat pump systems with no Aux heat with 24VAC Hot and Common available

DO NOT USE WITH:

Millivolt systems

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

-4°F to 149°F

WHITE-RODGERS

EMERSON ELECTRIC CO.

Printed in U.S.A.

PART NO. 37-6175D

9797 REAVIS ROAD

Replaces 37-6175C

ST. LOUIS, MISSOURI 63123-5398

 

 

0225

www.white-rodgers.com

 

INSTALLATION

REMOVE OLD THERMOSTAT

1.Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.

2.Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.

3.Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.

4.Disconnect the wires from old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

5.Install new thermostat using the following procedures.

ATTENTION!

This product does not contain mercury. However, this product may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded.

Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container and return to White-Rodgers at 9797 Reavis Road, St. Louis, MO, 63123-5398 for proper disposal.

ATTACH THERMOSTAT BASE TO WALL

1.Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit.

2.Connect wires beneath terminal screws on base using appropriate wiring schematic (see figs. 2 through 4).

3.Place base over hole in wall and mark mounting hole locations on wall using base as a template.

4.Move base out of the way. Drill mounting holes.

5.Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase.

6.Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

ELECTRIC/GAS JUMPER (Fan Option)

Read the following information before clipping the nonelectric heat jumper. If you are unsure of your application, contact a qualified service person.

If your emergency or auxiliary system will energize the blower, then jumper, W904, on the thermostat base must be cut (see fig. 1).

If your emergency or auxiliary heat system requires that the thermostat energize the fan circuit, do not cut jumper W904.

OPTIONAL BATTERIES

With two "AA" batteries installed, your thermostat will maintain time and continuously display the temperature during a loss

Optional (2) "AA" batteries

Screw anchors

O/B switch

W904

Mounting hole

Reset switch

(below Fan switch) W904

Mounting Electric/Gas hole

jumper

Figure 1. Thermostat Base

of AC power. Installed batteries will also allow programming prior to installation.

ENERGY MANAGEMENT RECOVERY (EMR)

When the EMR feature is activated the thermostat's microcomputer calculates the time it will take to change the room temperature to the next heat or cool program setting. Then the thermostat will start the system before the next programmed period so that the desired temperature is reached at or near the beginning of the period (the thermostat calculates 15 minutes for every 1°F temperature change). This minimizes the use of auxiliary stages during the transition period to reduce energy costs.

For example: The thermostat is programmed to provide an overnight heating temperature of 66°F, and during the next program period, beginning at 6:00 AM, the programmed temperature is 70°F. With EMR activated, the thermostat will automatically start the heating system at 5:00 AM, so that the programmed temperature of 70°F is reached by about 6:00 AM.

If the overnight room temperature drops only to 68F°, the thermostat will start the system at 5:30 to reach the programmed temperature of 70°F at 6:00.

The thermostat is shipped with the EMR feature active, which means that the thermostat will start the heating system before the beginning of the next program period. This feature provides better efficiency by allowing gradual temperature changes using only the first stage of heat.

To deactivate the EMR function, see the Configuration menu on Page 5). The thermostat will then wait until the programmed time to start the system for a temperature change.

O/B TERMINAL SWITCH SELECTION

The O/B switch on this thermostat is factory set to the “O” position. This will accommodate the majority of heat pump applications, which require the changeover relay to be energized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a “B” terminal, to energize the changeover relay in HEAT, the O/B switch must be moved to the “B” position.

2

White Rodgers 1F82-261 User Manual

THERMOSTAT

O/B

Y

 

G

 

W2

 

 

E

C

 

L

R

 

 

 

 

 

 

 

See Note **

 

 

SYSTEM

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changeover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

Emergency

 

 

MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay*

 

Compressor

 

 

Aux

 

 

 

 

SWITCH

 

 

 

 

 

 

Relay

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Stage 2)

 

 

 

 

24 VAC

 

 

 

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VAC

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

 

 

 

 

 

TRANSFORMER

** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency

 

 

(Class II Current Limited)

Figure 2. Typical wiring diagram for single transformer systems

NOTE

If safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits.

 

 

 

 

 

 

 

 

O/B

 

Y

 

G

 

W2

 

 

E

C

 

L

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

CUT AND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAPE OFF!

 

 

 

 

 

 

See Note **

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changeover

 

 

Fan

 

 

 

 

 

 

 

MONITOR

 

 

 

Limit or

 

 

 

HOT

 

 

 

 

Relay*

 

 

 

Relay

 

 

 

 

Emergency

 

 

SWITCH

 

 

Safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

 

Switches

 

 

 

120 VAC

 

 

 

 

24 VAC

Compressor

 

 

 

Aux

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot

 

NEUTRAL

 

 

 

 

 

 

 

 

 

(Stage 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWO COMMONS MUST

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

 

 

 

 

 

 

TRANSFORMER

 

BE JUMPERED TOGETHER!

 

 

 

 

(Class II Current Limited)

 

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

 

 

 

 

 

 

 

 

 

 

** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency

Figure 3. Typical wiring diagram for two transformer systems with NO safety circuits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Polarity must be

observed.

If the HOT side of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the second transformer is jumpered to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMMON side of the first transformer a short

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

will be made. Damage to equipment will occur

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

when power is restored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

O/B

 

Y

 

G

 

W2

 

E

C

 

 

L

R

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See Note **

 

 

 

 

 

 

 

 

 

Limit or

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety

 

HOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety

 

24 VAC

 

 

 

 

120 VAC

Switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

Switches

 

 

 

 

 

 

 

 

 

 

 

Changeover

 

 

Fan

 

 

 

Emergency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay*

 

 

 

Relay

 

 

 

Relay

 

 

SWITCH

 

 

 

 

 

24 VAC

 

 

 

 

Auxiliary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORY

 

 

Heating

 

 

 

 

NOTE

 

 

Compressor

 

 

 

Aux

 

 

 

 

 

 

 

 

 

 

 

RELAY N.O.

 

Transformer

The

 

accessory relay scheme

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACT

 

 

(Class II

is

required

when safety

 

 

 

 

 

(Stage 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Limited)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMMON

 

circuits exist in both systems.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWO COMMONS MUST

 

 

 

 

 

 

Limit or

 

 

 

 

 

 

 

 

 

 

Limit or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE JUMPERED TOGETHER!

 

 

 

Safety

 

 

 

 

 

 

 

 

 

 

 

Safety

HOT

* Changeover Relay is energized in COOL when O/B switch is in the “O” position

 

 

 

 

 

Switches

24 VAC

 

 

 

 

120 VAC

Switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changeover Relay is energized in HEAT when O/B switch is in the “B” position

 

 

 

 

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Class II Current Limited)

 

 

 

 

 

 

 

 

 

Figure 4. Typical wiring diagram for two transformer systems with safety circuits in BOTH systems

3