Whirlpool YWED5700SW, YLER8648PW, YCEDS563SQ, YCEDS563RQ, YLER4634JQ Installation Instructions

...
0 (0)

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION

INSTRUCTIONS

INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE

ÉLÉCTRIQUE DE 29 PO (73,7 CM)

TableofContents/TabledesMatières

DRYER SAFETY...............................................

1 SÉCURITÉ DE LA SÉCHEUSE ........................

8

INSTALLATION INSTRUCTIONS....................

2

Tools and Parts .............................................

2

Location Requirements ................................

2

Electrical Requirements ................................

3

Venting Requirements...................................

4

Plan Vent System..........................................

4

Install Vent System........................................

5

Install Leveling Legs......................................

6

Level Dryer ....................................................

6

Connect Vent.................................................

6

Reverse Door Swing (Optional).....................

6

Complete Installation ....................................

7

INSTRUCTIONS D’INSTALLATION.................

8

Outillage et pièces nécessaires .....................

8

Emplacement d’installation ..........................

9

Installations électriques ...............................

10

Exigences concernant l’évacuation.............

11

Planification du système d’évacuation........

11

Installation du conduit d’évacuation............

13

Installation des pieds de nivellement...........

13

Mise à niveau de la sécheuse......................

13

Conduit d’évacuation...................................

14

Inversion de l’ouverture de la porte.............

14

Achever l’installation ....................................

15

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

8535831

Whirlpool YWED5700SW, YLER8648PW, YCEDS563SQ, YCEDS563RQ, YLER4634JQ Installation Instructions

INSTALLATION INSTRUCTIONS

Tools and Parts

Check that you have everything necessary for correct installation. Proper installation is your responsibility.

flat-blade screwdriver

adjustable wrench that opens to 1 in. or hexhead socket wrench (for adjusting dryer feet)

level

#2 Phillips screwdriver

safety glasses

caulking gun and compound (for installing new exhaust vent)

gloves

tin snips (new vent installations)

Parts supplied

Remove parts package from dryer drum. Check that all parts were included.

4 leveling legs

Parts needed:

Check local codes, check existing electrical supply and venting and see “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the front page of your “Dryer User Instructions.”

Location Requirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30 amp circuit.

A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total weight (dryer and load) of 200 lb (90.7 kg).

A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Extended Dryer Feet Kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

Install the dryer where it is protected from water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

1.Small Opening Side-Swing Door

2.Large Opening Side-Swing Door

3.Wide Opening Side-Swing Door

4.Wide Opening Hamper Door

*Most installations require a minimum 5½ in. (14 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Minimum installation spacing for recessed area or closet installation

The dimensions shown following are for the minimum spacing allowed.

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

2

Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

 

 

"

 

 

"

 

 

"

 

"

 

 

 

"

 

 

"

"

"

"

3

1.Recessed area

2.Side view - closet or confined area

3.Closet door with vents

Mobile Home-Additional Installation Requirements

This dryer is suitable for mobile home installations. The installation must conform to the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware which is available for purchase from your dealer.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

A 4 wire, single phase, 115/230-volt, 60-Hz., AC-only electrical supply is required on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-wire receptacle 14-30R

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. For further information, please reference the service numbers located in your “Dryer User Instructions.”

Replacement Power Supply Cord must be:

UL Listed or CSA International Certified

Marked for use with clothes dryers

Rated 115/230 volt minimum

30 amp

Type SRD or SRDT

4 conductors

At least 4 ft (1.22 m) long

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction

or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

3

Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

4 in. (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of your “Dryer User Instructions.”

Do not exhaust the dryer into any gas vent, chimney, wall, ceiling, or a concealed space of a building.

Do not use an exhaust hood with a magnetic latch.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Do not use screws or other fastening devices that extend into the interior of the vent to secure vent.

IMPORTANT: Observe all governing codes and ordinances.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Use a heavy metal vent. Do not use plastic or metal foil vent. Rigid metal vent is recommended to prevent crushing and kinking.

Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

An exhaust hood should cap the vent to prevent rodents and insects from entering the home.

Exhaust hood must be at least 12 in. (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Plan Vent System

Typical exhaust installations

Typical installations vent the dryer from the rear of the dryer.

1.

Dryer

5.

Clamps

2.

Elbow

6.

Rigid metal or flexible metal vent

3.

Wall

7. Vent length necessary to connect elbows

4.

Exhaust hood

8.

Exhaust outlet

Standard exhaust installation with rigid metal or flexible metal vent

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

1

 

2

 

 

 

 

 

 

 

1.Over-The-Top installation (also available with one offset elbow)

2.Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the service numbers located in your “Dryer User Instructions.”

Over-The-Top Installation: Part Number 4396028

4

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0 in. (0 cm) to 18 in. (45.72 cm) mismatch

Part Number 4396011 - 18 in. (45.72 cm) to 29 in. (73.66 cm) mismatch

Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure. Do not use screws or other fastening devices that extend into the interior of the vent to secure vent.

Terminate the exhaust vent outside. The exhaust vent must not terminate beneath the mobile home and must not be connected to any other duct, vent or chimney.

Determine Vent Length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90º turns.

The angled hood style (shown following) is acceptable.

4" (10.2 cm)

2.5" (6.4 cm)

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

3.Determine the number of elbows you will need.

NOTE: Do not use vent runs longer than specified in the Vent Length Chart.

The chart below helps you determine your maximum vent length based on the number of 90° turns or elbows you will need and the type of vent (rigid or flexible metal) and hood that you will use.

Vent Length Chart

Number of

Type of vent

Box or

Angled

90º turns

 

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

2

1

4" (10.2 cm)

4" (10.2 cm)

1.Louvered hood style

2.Box hood style

Install Vent System

1.(Optional) Put on safety glasses and gloves.

2.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

3.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp.

4.Run vent to dryer location. Use the straightest path possible. See “Determine Vent Length.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

5

Loading...