Model AWZ 126 Version 8575 126 89000 Page
Technical data 2 - 3
Spare part list 4
Exploded view 5
Wiring diagram 6
Circuit diagram 7
Service Manual
Tumble dryer Air Vent AWZ 126
AWZ 126
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 02.04.1997 Subject to modification Document-No.: 4812 713 11036
SERVICE
02.04.1997 / Page 2 Whirlpool Europe Doc. No: 4812 713 11036 Customer Service
Technical data
Dimensions
Height 85,0 cm Width 59,5 cm Depth 56,0 cm
Weight
Gross weight 33 kg Net weight 31 kg
Surroundings temperature
Max.room temperature 35 ˚C Min. room temperature 5 ˚C
Humidity
Max. relative humidity 95 %
Power connection
Voltage 220 V Frequency 60 Hz Connected load 2,2 kW Fuse 10 A
Drum data
Volume 104 l Drum speed (empty) 56 ± 3 rpm Airflow 120 - 160 m3 /h
Maximum loading capacity
Cotton 5 kg Easy care 2,5 kg
Exhaust hose
Inner diameter 10 cm Maximum allowable 4 m (with 2 bows)
Electrical components
Heating
Type Aluminium mass
heating Nominal voltage 230 V Nominal power 2050± 5%W Resistor R 20 23,5-28
Thermostats
Safety thermostat(in heater) TL
Switch off temperature 270 ± 10 ˚C
Fluff thermostat (in heater) TH 1.2
Switch on temperature 180 ± 7,5 ˚C Switch off temperature 205 ± 7,5 ˚C
Exhausting thermostat (in bottom) TH 1.1
Switch on temperature 45 ± 5 ˚C Switch off temperature 60 ± 4 ˚C
Timer
Type electromechanical
Timer, Eaton
EC 4511 Nominal voltage 220 V Frequency 60 Hz Number of steps 60
- Stop 01
- Heating (173 min) 02 - 53
- Cool down (6 min) 54 - 55
- Anticreasing (13 min) 56 - 59
- Stop 60 Ambient temperature up to 70 ˚C Storage temperature up to 85 ˚C
Main- and blower motor
Type 1-phase asynchronous Nominal voltage 220 V Frequency 60 Hz Power consumption 295± 7% W Resistances of coils Main coil (2-3) 21,5± 7% Auxiliary coil (2-1) 21,5± 7%
Rated speed with 5kg laundry and 100 % rest humidity 2750 rpm Capacitor 10± 10% µ F
SERVICE
Whirlpool Europe 02.04.1997 / Page 3 Customer Service Doc. No: 4812 713 11036
Technical data
Push buttons
Gentle switch SG
Nominal voltage 230 +10%/-15% V Nominal current 16 A
Start / door switch
Start switch SST
Nominal voltage 230 +10%/-15% V Nominal current 16 A
Door switch SD
Nominal voltage 230 +10%/-15% V Nominal current 16 A
Radio interference filter
Type Eichhoff F11.126 Nominal voltage 110/250 V Nominal capacity 0,47 µ F± 20% + 2x500 µ H-30%/+50% + 680 K 0,5W
Buzzer
Nominal voltage 230 +10%/-15% V Resistance of coil 7 ± 15 % K