ARC 5561
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 25.03.2004 Subject to modification
Document-No.: 4812 731 19471

25.03.2004 / Page 2 ARC 5561 Whirlpool Europe
Doc. No: 4812 731 19471 8501 556 10020 Customer Service
Technical data
SERVICE
Factory Code CB 282 W
Dimensions
Height 187.5 cm
Width 60.0 cm
Depth 62.1 cm
Capacity
Total
gross 320 l
net 302 l
Cooling
gross 212 l
net 210 l
Freezing
gross 108 l
net 92 l
Electrical connection
Voltage 220 - 240 V
Frequency 50 Hz
Power consumption
in 24 hours 0.93 kWh
Freezing capacity
Refrigerant (cooling)
Type R 600 a
Quantity 22 g
Refrigerant (freezing)
Type R 600 a
Quantity 37 g
Thermostat switching value (cooling)
Switch on temperature
min. + 3.5 ˚C
Switch on temperature
max. + 3.5 ˚C
Switch off temperature
min. - 8.0 ˚C
Switch off temperature
max. - 26.0 ˚C
Thermostat switching value (freezing)
Switch on temperature
min. - 14.5 ˚C
Switch on temperature
max. - 21.5 ˚C
Switch off temperature
min. - 25.0 ˚C
Switch off temperature
max. - 32.0 ˚C
in 24 hours 10 kg
Compressor (cooling)
Type TLES 5 KK 2
Capacity (CECOMAF) 57 W
Compressor (freezing)
Type HLY 90 AA
Capacity (CECOMAF) 109 W