AKM 532 PRODUCT DESCRIPTION SHEET
FR
1.
1
3
2
44
4
5
Removable panstand grids
2.
Medium burner
3.
Rapid electric hotplate
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Hotplate control knob
10.
Electric hotplate operation lamp
10
7
9 6
8
Operation of burners with electronic
ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Symbols
Shaded circle Tap closed
Large flame
and star
Small flame Minimum opening or
Maximum opening/delivery
and electric ignition
reduced delivery
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Operation of the electric hotplate
Set the knob to one of positions
correspond to different temperatures.
To switch off the hotplate, set the knob to
position "0".
1-6
, which
5019 319 53991
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for
the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3
G25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5
G30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3
G31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
burner
large
medium
small
large
medium
small
large
medium
small
large
medium
small
Injector
marking
100/mm
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat
capacity
kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
capacity kW
Rated
consumption
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for
burning m3/h
ELECTRIC SUPPLY: 230 V - 50 Hz
ELECTRIC HOT PLATE POWER: 1500 W.