AKM 525 PRODUCT DESCRIPTION SHEET
NL
1.
Removable panstand grids
2.
Large burner
3-4.
Medium burners
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
Note:
—
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
—
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
5019 319 01414
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY 112L3B/P
Typ e o f g as
used
NATURAL GAS
(Methane) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31
Typ e o f
burner
large
medium
small
large
medium
small
large
medium
small
Injector
marking
F 126
T8 96
F1 72
87
65
50
87
65
50
Rated
heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Rated
consumption
332 l/h
183 l/h
111 l/h
218 g/h
120 g/h
73 g/h
218 g/h
102 g/h
62 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.35
0.60
0.35
0.30
0.60
0.35
0.35
Gas pressure mbar
min. rat. max.
20 25 30
25 30 35
25 30 35
Typ e o f g as us ed
G25 25 mbar 4 gas 7.30 809 l/h 8.187
G30 30 mbar 4 gas 7.30 531 g/h 30.94
G31 30 mbar 4 gas 7.30 531 g/h 30.94
Appliance
model
Total rated heat
capacity
kW
Total rated
consumption
Air necessary (m
for the combustion
of 1 m
ELECTRIC SUPPLY: 230 V ~ 50 Hz
3
of gas
3
)