Whirlpool AKM 520/IX/01, AKM 522/IX/01 INSTRUCTION FOR USE

AKM 520-522/01 PRODUCT DESCRIPTION SHEET
ES PT IT
1. Removable panstand grids
2. Large burner 3-4. Medium burners
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burners ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
5019 319 53052
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS
(Cylinder) G30 LIQUID PETROLEUM
GAS (Cylinder) G31
Type of burner
large medium small
large medium small
large medium small
Injector marking 100/mm
128
94 76
85 65 50
85 65 50
Rated heat capacity kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Rated consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6 G30 28-30 mbar 4 gas 7.30 531 g/h 14.6 G31 37 mbar 4 gas 7.30 521 g/h 14.6
Appliance model
Total rated heat capacity kW
Total rated consumption
Air required for burning
m
ELECTRIC SUPPLY: 230 V - 50 Hz
3
/h