AKM 520-522/01 PRODUCT DESCRIPTION SHEET
ES PT IT
1. Removable panstand grids
2. Large burner
3-4. Medium burners
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, keep the knob pressed
against the control panel until the burners
ignites.
• After the burner has ignited, keep the knob
pressed for about 10 seconds.
• Release the knob.
If the burner does not ignite, repeat the operations
described above.
Shaded
circle
Large
flame
and star
Small
flame
Tap closed
Maximum opening/delivery
and electric ignition
Minimum opening or
reduced delivery
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
— The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
5019 319 53052
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Injector
marking
100/mm
128
94
76
85
65
50
85
65
50
Rated heat
capacity
kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced
heat
capacity
kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Type of gas used
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G31 37 mbar 4 gas 7.30 521 g/h 14.6
Appliance
model
Total rated heat
capacity
kW
Total rated
consumption
Air required
for burning
m
ELECTRIC SUPPLY: 230 V - 50 Hz
3
/h