3gb66033.fm Page 1 Thursday, May 22, 2003 9:28 AM
AKM 474 PRODUCT DESCRIPTION SHEET
FR
1. Radiant cooking zone Ø 180, 1700W
2. Haloring cooking zone Ø 145, 1200W
3. Large burner
4. Small burner
5. Front left cooking zone control knob
6. Rear left cooking zone control knob
7. Large burner control knob
8. Small burner control knob
Symbols
Operation of burners with safety
device and electric ignition
To light one of the burners:
• Press the relative knob an d turn it anti-clockwise
to the large flame and star setting .
• At the same time, hold th e kn ob d own un til th e
burner ignites.
• After the burner has ignited, keep th e knob
pressed for about 10 seconds.
• Release the knob.
If the burner does n ot ignite, repeat the oper ati on s
described above.
Note:
— Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Shaded
circle
Large flame
and star
Small flame
— The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
— The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
Tap closed
Maximum opening/delivery
and electric igniti on
Minimum opening or
reduced delivery
A wooden shelf must be
installed below the cooktop
with a minimum thickness of
20 mm, at least 15 mm from the
bottom of the surface itself.
5019 319 66033
3gb66033.fm Page 2 Thursday, May 22, 2003 9:28 AM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used Appliance model Total rated heat
G20 20 mbar 2 Gas+2VC 4.0 381 l/h 8.0
G25 25 mbar 2 Gas+2VC 3.71 411 l/h 7.42
G30 28-30 mbar 2 Gas+2VC 4.0 291 g/h 8.0
G31 37 mbar 2 Gas+2VC 4.0 285 g/h 8.0
burner
large
small
large
small
large
small
large
small
Injector
marking
130833.00
130832.78
85503.00
85503.00
Rated heat
capacity
kW
1.00
0.93
1.00
1.00
capacity kW
Rated
consumption
286 l/h
95 l/h
308 l/h
103 l/h
218 g/h
73 g/h
214 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
kW
0.80
0.50
0.80
0.50
0.80
0.50
0.80
0.50
Gas pressure mbar
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for
burning m
3
/h
ELECTRIC SUPPLY:
230 V - 50 Hz
VETROCERAMIC HOT PLATE POWER:
Rear left zone:
1200W
Front left zone: 1700W