AKM 433 PRODUCT DESCRIPTION SHEET
GB IE
1. Removable panstand grids
2. Large burner
3-4. Medium burners
5. Auxiliary burner
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Auxiliary burner control knob
10. Timer control knob
Symbols
Shaded circle Valve closed
High flame
and star
Low flame
Maximum aperture/supply
and electric ignition
Minimum
aperture/supply
Electrically ignited gas burner user
instructions
How to ignite one of the burners:
• Push and turn the corresponding knob anticlockwise until the reference is aligned with the
high flame and star symbols .
• At the same time, keep the knob pressed
against the control panel until the burner
ignites.
• At the same time hold the knob against the
control panel until the burner ignites.
• Release the knob.
If the burner fails to ignite, repeat the sequence.
Note:
- If problems with local gas supply impede burner
ignition, repeat the sequence by turning the knob
to the low flame symbol .
5019 319 61251/A
Using the timer
This particular model features a mechanical timer
which can time up to one hour of cooking.
• Turn the knob clockwise until the reference is
aligned with the desired cooking time.
• When the set time elapses an acoustic signal is
activated.
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
— cast iron griddles or terracotta pots and pans
— heat diffusers such as metal mesh, or any
other types
— two burners simultaneously for one
receptacle (e.g. fish kettle).
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: If the distance “A“ between the wall cabinets is between 600 mm and 680 mm,
the height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G 20
LIQUIFIED PETROLEUM
GAS
(Cylinder) G 30
LIQUIFIED PETROLEUM
GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
128
94
76
85
65
50
85
65
50
Total rated heat
capacity
Pcs-kW
Rated
heat
capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Gas pressure
Air required
for burning
3
m
/h