SERVICE
Model AKM 267/NA
Version 8571 267 10000 Page
Whirlpool Europe
Customer Services
AKM 267/NA
Service Manual
Gas hob
AKM 267/NA
Technical data 2
Spare part list 3
Exploded view 4
Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 02.12.2004 Subject to modification
Document-No.: 4812 725 19258
02.12.2004 / Page 2 AKM 267/NA Whirlpool Europe
Doc. No: 4812 725 19258 8571 267 10000 Customer Service
Technical data
1. Removable panstand grids
2. Medium burner
3. Medium burner
4. Large burner
5. Small burner
SERVICE
Voltage: 230 V
Frequency: 50 Hz
Type of
gas used
Natural gas
(Methane)
G20
LPG
(Cylinder)
G30
LPG
(Cylinder)
G31
Type of gas used Appliance
G20 20 mbar 4G 7.30 695 l/h 14.6
G30 28-30 mbar 4G 7.30 531 g/h 14.6
G31 37 mbar 4G 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Injector
marking
model
128
94
76
85
65
50
85
65
50
Rated heat
capacity
(kW)
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity
(kW)
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reducedheat
capacity
(kW)
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
Gas pressure
(mbar)
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning (m3 /h)