Whirlpool AKM 250/CF Service Manual

SERVICE
Model AKM 250/CF Version 8571 250 38040 Page
Whirlpool Europe Customer Services
AKM 250/CF
Service Manual
Hob AKM 250/CF
Technical data 2
Spare part list 3
Exploded view 4
Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 05.12.1997 Subject to modification Document-No.: 4812 715 15379
05.12.1997 / Page 2 AKM 250/CF Whirlpool Europe Doc. No: 4812 715 15379 8571 250 38040 Customer Service
Technical data
1. Medium Burner
2. Medium Burner
3. Large Burner
4. Small Burner
SERVICE
Type of gas used Type of
burner
Natural Gas (Methane) G 20
Natural Gas (Cylinder) G 30
Natural Gas (Cylinder) G 31
large
medium
small
large
medium
small
large
medium
small
Injector
marking
128
94 76
85 65 50
85 65 50
Rated heat
capacity PCS-kW
3,00 1,65 1,00
3,00 1,65 1,00
3,00 1,65 1,00
Voltage: 230 V Frequency: 50 Hz
Rated
consumption
286 l/h 157 l/h
95 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Reducedheat
capacity PCS-kW
0,60 0,35 0,30
0,60 0,35 0,30
0,60 0,35 0,30
Gas pressure (mbar)
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Type of gas used Appliance
model
G20 20 mbar 4 gas 7,3 695 l/h 14,6
G30 28-30 mbar 4 gas 7,3 531 g/h 14,6
G31 37 mbar 4 gas 7,3 521 g/h 14,6
Total rated heat
capacity PCS-kW
Total rated
consumption
Air required for
burning m/h
Loading...