Whirlpool AKM 214/WH/01, AKM 214/WH, AKM 214/NA/01, AKM 214/AR, AKM 214/NA INSTRUCTION FOR USE

...
AKM 214 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2. Medium burner
3. Rapid electric hotplate
4. Large burner
5. Small burner
6. Medium burner control knob
7. Large burner control knob
8. Small burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Operation of burners with electronic ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignities.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 61111
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electronic ignition
Minimum opening or reduced delivery
Operation of the electric hotplate
Set the knob to one of positions 1-6, which correspond to different temperatures.
To switch off the hotplate, set the knob to position “0”.
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G 20 NATURAL
GAS (Methane) G 25
LIQUID PETROLEUM GAS
(Cylinder) G 30 LIQUID PETROLEUM
GAS (Cylinder) G 31
Type of gas used Appliance model Total rated
G 20 20 mbar 3 gas + 1 E 5.65 538 l/h 11.3 G 25 25 mbar 3 gas + 1 E 5.24 581 l/h 10.5 G 30 28-30 mbar 3 gas + 1 E 5.65 411 g/h 11.3 G 31 37 mbar 3 gas + 1 E 5.65 403 g/h 11.3
burner
large medium small
large medium small
large medium small
large medium small
Injector marking
128
94 76
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 g/h 120 g/h
73 g/h
214 g/h 118 g/h
71 g/h
Total rated consumption
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning
m
ELECTRIC HOTPLATE POWER: 1500 W.
Gas pressure
3
/h
Loading...