AKM 210 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electronic ignition button
Symbols
Shaded circle Tap closed
Large Maximum opening/
flame delivery and electric
and star ignition
Small Minimum opening or
flame reduced delivery
Operation of burners
with electronic ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star
setting .
• At the same time, press the bu tton with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, repeat the
operations described above.
Note:
— Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS
(Methane) G 20
NATURAL GAS
(Groningue) G 25
LIQUID PETROLEUM
GAS
(Cylinder) G 30
LIQUID PETROLEUM
GAS
(Cylinder) G 31
Type of gas used Appliance
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 25 25 mbar 4 gas 6.77 751 l/h 13.5
G 25 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
burner
large
medium
small
large
medium
small
large
medium
small
large
medium
small
model
Injector
marking
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat
capacity
Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat
capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 l/h
120 l/h
73 l/h
214 l/h
118 l/h
71 l/h
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated
consumption
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required
for burning
3
m
Gas pressure
/h
5019 319 60131