AKM 210 PRODUCT DESCRIPTION SHEET
FR
1. Removable panstand grids 2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electronic ignition button
Symbols
Shaded circle Tap closed Large Maximum opening/
flame delivery and electric and star ignition
Small Minimum opening or flame reduced delivery
Operation of burners with electronic ignition
To light one of the burners:
Press the relative knob and turn it anti­clockwise to the large flame and star setting .
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of
NATURAL GAS (Methane) G 20
NATURAL GAS (Groningue) G 25
LIQUID PETROLEUM GAS
(Cylinder) G 30 LIQUID PETROLEUM
GAS (Cylinder) G 31
Type of gas used Appliance
G 20 20 mbar 4 gas 7.30 695 l/h 14.6 G 25 25 mbar 4 gas 6.77 751 l/h 13.5 G 25 28-30 mbar 4 gas 7.30 531 g/h 14.6 G 31 37 mbar 4 gas 7.30 521 g/h 14.6
burner
large medium small
large medium small
large medium small
large medium small
model
Injector marking
128
94 76
128
94 76
85 65 50
85 65 50
Rated heat capacity Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
Total rated heat capacity Pcs-kW
Rated consumption
286 l/h 157 l/h
95 l/h
308 l/h 170 l/h 103 l/h
218 l/h 120 l/h
73 l/h
214 l/h 118 l/h
71 l/h
Reduced heat capacity Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Total rated consumption
min. rat. max.
17 20 25
20 25 30
20 28-30 35
25 37 45
Air required for burning
3
m
Gas pressure
/h
5019 319 60131