AKL 700 PRODUCT DESCRIPTION SHEET
GB
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Operation of burners
with electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting .
• At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
If the burner does not ignite, repeat the operation.
Shaded
circle
Large flame
Small flame
Tap closed
Maximum opening/
delivery
Minimum opening or
reduced delivery
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
5019 519 60041

DIMENSIONS OF COOKING HOB AND WORKTOP
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
NATURAL GAS
(Methane) G 20
LIQUID
PETROLEUM GAS
(Cylinder) G 30
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Type of gas
used
G 20 20 mbar 4 gas 7.30 695 l/h 14.6
G 30 28-30 mbar 4 gas 7.30 531 g/h 14.6
G 31 37 mbar 4 gas 7.30 521 g/h 14.6
Type of
burner
large
medium
small
large
medium
small
large
medium
small
Appliance
model
Injector
marking
128
94
76
85
65
50
85
65
50
Rated
heat
capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
Total rated
heat capacity
Pcs-kW
Rated
consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated
consumption
Reduced
heat
capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required
for burning
3
m
Gas pressure
/h