Whirlpool AKF 597 IX INSTRUCTION FOR USE

5en66002.fm Page 1 Friday, October 24, 2003 3:17 PM
AKF 597/IX PRODUCT DESCRIPTION SHEET
GB
1.
Removable grids
2-5.
Medium burners
3.
Large burner
4.
Auxiliary burner
6.
Triple crown burner
7.
Front left burner control knob
8.
Rear left burner control knob
9.
Central burner control knob
10.
Rear right burner control knob
11.
Front right burner control knob
Symbols
Operation of burners with safety device and electric ignition
To light one o the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.  Release the knob. If the burner does not ignite, repeat the operation.
Note:
Should particular local conditions of the delivered gas make ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Shaded circle
Large flame and star
Small flame
The burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of a sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The separator panel, positioned beneath the cooktop at a minimum distance of 20 mm, must be sealed.
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Insert a wooden panel at least 20 mm thick under the hob, at a distance of at least 15 mm from the cooking hob bottom.
5019 519 66002
5en66002.fm Page 2 Friday, October 24, 2003 3:17 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be at least 520 mm. If the distance A between the wall cabinets is greater than the width of the hob, the height B must be a minimum of 400 mm. Before installing a hood above the hob please refer to the hood instructions, which specify the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used Type of
NATURAL GAS (Methane) G20
LIQUID PETROLEUM GAS
(Cylinder) G30
LIQUID PETROLEUM GAS
(Cylinder) G31
Type of gas used
G20 20 mbar 5 gas 11 1048 22
G30 28-30 mbar 5 gas 11 799 22
G31 37 mbar 5 gas 11 799 22
burner
triple crown rapid semi-rapid auxiliary
triple crown rapid semi-rapid auxiliary
triple crown rapid semi-rapid auxiliary
Appliance model Total rated heat
Injector marking 100/mm
135 130 105
83
92 85 65 50
92 85 65 50
Rated heat capacity kW
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
3.50
3.00
1.75
1.00
capacity kW
Rated consumption
333 l/h 286 l/h 167 l/h
95 l/h
254 g/h 218 g/h 127 g/h
73 g/h
254 g/h 218 g/h 127 g/h
73 g/h
Total rated consumption
Reduced heat capacity kW
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
1.50
0.80
0.50
0.50
Gas pressure mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required for
burning m
3
/h
Loading...