Whirlpool AGB 517/WP, AGB 596/WP, AGB 518/WP, AGB 595/WP INSTRUCTION FOR USE

049_03
Instructions for installation, use and maintenance
11/2005
AGB 595/WP • AGB 596/WP AGB 517/WP • AGB 518/WP AGB 512/WP • AGB 513/WP
APPLIANCES WITH MECHANICAL VALVE
049-03 - Gas fryers
2
INDEX
Dimensions page 3
Data of appliances 4
Technical data 4-5
Operating instructions 6
Construction, equipment installed
and safety devices 6
Assembly 6
Location 6
Legal and technical requisites 6
Installation 6
Installation procedure 7
Gas connection 7
Gas venting 7
Equipotential 7
Commissioning the appliance 7
Before commissioning the appliance 7
Start-up 7
Testing the power rating 7
Checking input pressure 7
Checking power rating using
the volumetric method 7
Checking power rating when using
LP gas 8
Checking the pilot light 8
Checking the primary air 8
Checking the functions 8
Note for the installer 8
Running the appliance on other types
of gas page 8
Replacing the main burner nozzle 8
Adjusting the pilot burner 9
Adjusting the primary air 9
Maintenance 9
Replacing parts 9
Valve 9
Safety termostat 9
Burner 9
Thermocouple 9
Ignition plug 9
Using the appliance 11
Preparation for use 11
Filling the tank 11
Turning on and off 11
Lighting the main 11
Burner of the tank 11
Extinguishing 11
Emptying the tank 11
Table-top version 11
Floor-stading version 12
Turning off in an emergency 12
What to do in the case of malfunctioning
or if the appliance is not to be used
for a long period 12
Taking care of the appliance -
frequency of maintenance 12
Warning 13
049-03 - Gas fryers
3
Dimensions
800
430
25
400
400
15 1/2"GC
655800
1/2"GC
510
25
15 1/2"GC
700
1/2"GC
151/2"GC
AGB 595/WP
SKF 10GMAGB 596/WP
151/2"GC
300
300
800
1/2"GC 25
AGB 512/WPAGB 513/WP
1085
875
1/2"GC
25
400
1/2"GC
208
700
AGB 517/WPAGB 518/WP
049-03 - Gas fryers
4
2 - CHARACTERISTICS OF THE APPLIANCES
The instructions contained in this manual apply to our gas fryers in the II2H3+ category (see table on page 5).
control panel. It contains all necessary reference data such as the name of the manufacturer, input pressure, gas type setting, etc.
The data plate is located on the front of the appliance and on the
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 -
II2H3+ P mbar 30 37 20--
II2H3+ P mbar 28 37 20 -
0051 TIPO/TYPE
MOD.
ART.
N.
N.
Qn kW
MOD.
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE. THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
m3/h
II2ELL3B/P P mbar 50 50 20 20
II2E+3+ P mbar 28 37 20 25
II2H3B/P P mbar 50 50 20 -
I2E P mbar - - 20 -
--II2H3B/P P mbar 30 30
II2H3+ P mbar 28 37 20 -
I3B/P P mbar 30 30
I3+ P mbar 28 37
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: -
--
--
Geschuckt voor:
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
25II2L3B/P P mbar 30 30
DE
FR BE
AT C H
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MADE IN ITALY
G30/G31 28/37 mbar
G20 20 mbar
Model
AGB 595/WP
AGB 596/WP
AGB 512/WP
AGB 513/WP
AGB 517/WP
AGB 518/WP
3 - TECHNICAL DATA
Description
Gas deep fat fryer - 1 tank - manual control
Gas deep fat fryer - 2 tanks - manual control
Gas deep fat fryer - 1 tank - manual control
Gas deep fat fryer - 2 tanks - manual control
Gas deep fat fryer - 1 tank - manual control
Gas deep fat fryer - 2 tanks - manual control
Dimensions (LxPxH+H
1) - mm.
400 x 655 x 430-300
800 x 655 x 430-300
400 x 700 x 510-300
800 x 700 x 510-300
400 x 700 x 1085-875
800 x 700 x 1085-875
Basins Nr.
1
2
1
2
1
2
Capacity - Lt.
10
10 + 10
10
10 + 10
10
10 + 10
Nr.
51BQ2904
51BQ2904
51BQ2904
51BQ2904
51BQ2904
51BQ2904
Loading...