027_03
Installation, operating and
maintenance instructions
07/2007
ELECTRIC PASTA COOKER
AGB 449/WP· AGB 451/WP
AGB 056/WP
· AGB 058/WP

027-03 - Electric pasta cooker
2
Models and dimensions pag. 3
Technical data 4
Installation instructions 5
Installation 5
Legal and technical requisites 5
Installation 5
Wiring 5
Unipotential 5
Connection to waterworks 5
Using the appliance 6
Ignition 6
Emptying the bath 6
Taking care of the appliance
frequency of maintenance 6
Daily cleaning 6
Precautions during use 6
Protection of stainless steel 7
What to do if not using the appliance for
a long time 7
What to do if something goes wrong 7
Maintenance 7
WEEE Directive 7
Wiring diagrams 8-10
Warning 11
INDEX

027-03 - Electric pasta cooker
3
A
E
C
B
100
21
400
900
170
875
130
160
130
80
D
G
F
D
F/G
900
170
875
80
G
F
D
F/G
130
160
130
130
160
130
100
21
800
D
B
E
C
A
AGB 449/WP - AGB 056/WP
72 kg / 62 kg
AGB 451/WP - AGB 058/WP
128 kg / 112 kg
C Swicht
B Load lever
A Water filling tap
D Water outlet
1
/2 “ gas M.
E Pilot lamp
F Electric connection EL
G Water inlet ø 12
Weight approx.
Weight approx.
Water inlet ø 12

027-03 - Electric pasta cooker
4
2 - CHARACTERISTICS OF THE APPLIANCES
These appliances are used for professional purposes.
Installation, repair and use must be carried out by expert
The data plate is located on the front part of th
appliance (on the control panel).
personnel.
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 -
II2H3+ P mbar 30 37 20--
II2H3+ P mbar 28 37 20 -
TIPO/TYPE
MOD.
ART.
N.
N.
Qn kW
MOD.
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
m3/h
II2ELL3B/P P mbar 50 50 20 20
II2E+3+ P mbar 28 37 20 25
II2H3B/P P mbar 50 50 20 -
I2E P mbar - - 20 -
--II2H3B/P P mbar 30 30
II2H3+ P mbar 28 37 20 -
I3B/P P mbar 30 30
I3+ P mbar 28 37
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: -
--
--
Geschuckt voor:
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
25II2L3B/P P mbar 30 30
DE
FR BE
AT CH
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MADE IN ITALY
Model
AGB 449/WP
AGB 451/WP
AGB 056/WP
AGB 058/WP
Dim.: LxWxH
400 x 900 x 875
800 x 900 x 875
400 x 900 x 530
800 x 900 x 530
3 - TECHNICAL DATA
Tanks
1
2
1
2
Baskets
3
3 + 3
3
3 + 3
Voltage rating
430V 3N / 230 V 3
430V 3N / 230 V 3
430V 3N / 230 V 3
430V 3N / 230 V 3
Power
7.5 kW
15.0 kW
7.5 kW
15.0 kW
Lead wire / Section
4 x 4 mm2 / 5 x 2.5 mm
4 x 6 mm2 / 5 x 4 mm
2
4 x 4 mm2 / 5 x 2.5 mm
4 x 6 mm2 / 5 x 4 mm
2
2
2